Designs and electric properties studied of 3D trench electrode Si detector with adjustable central collection electrode
Source abstract
Abstract
In order to improve the radiation resistance of semiconductor detector, 3D trench electrode Si detector structures have been proposed by the Brookhaven National Laboratory (BNL) in 2009. In this paper, we propose a 3D trench electrode Si detector with adjustable central collection electrode, which integrates advantages of cylindrical units and parallel units. For those combined units, we use 1D Poisson equation as the first order approximation to study the changing of depletion in different regions. These results have been compared to those obtained from the full 3D simulation using a 3D-TCAD tool. According to calculations, we design a 3D trench electrode Si detector with adjustable central collection electrode. Furthermore, electrical characteristics of this type of detectors with different lengths of central collection electrode (lp+) have been simulated using the 3D-TCAD. Regarded as the main factor of signal-noise ratio, the geometric capacitance obtained from Silvaco TCAD simulations is compared with which is calculated by physical models when detectors size varies. Finally, the physic model of charge collection is established using Ramo theorem. The CCE (Charge Collection Efficiency) of detector unit is studied with this model (after Φ=1016 neq/cm2, average CCE is 38%).
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Particle Detector Development and Performance · Silicon Nanostructures and Photoluminescence · CCD and CMOS Imaging Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Materials Science and Engineering, Xiangtan University 1 , Xiangtan 411105, China
Center for Semiconductor Particle and Photon Imaging Detector, Development and Fabrication, Xiangtan University 2 , Xiangtan 411105, China
References (19)
Show source-provided references
1. J. Appl. Phys. · 1997 · 82 · 12610.1063/1.365790 ↗
2. Nucl. Instrum. & Meth. A · 1989 · 279 · 26610.1016/0168-9002(89)91091-7 ↗
3. IEEE Trans. Nucl. · 1999 · 46 · 22110.1109/23.775518 ↗
4. 1992
5. The physics of radiation damage in particle detectors10.1016/0168-9002(87)90532-8 ↗
6. Nucl. Instr. and Meth. A · 1997 · 395 · 32810.1016/s0168-9002(97)00694-3 ↗
7. IEEE Trans. Nucl. Sci. · 1999 · NS46 · 122410.1109/23.785737 ↗
8. Nucl. Instr. and Meth. A · 2007 · 572 · 30510.1016/j.nima.2006.10.232 ↗
9. Nucl. Instr. and Meth. A · 2005 · 541 · 44110.1016/j.nima.2005.01.087 ↗
10. Nucl. Instr. and Meth. A · 2008 · 586 · 18010.1016/j.nima.2007.12.005 ↗
11. Nucl. Instr. and Meth. A · 2011 · 658 · 9010.1016/j.nima.2011.05.003 ↗
12. Nucl. Instr. and Meth. A · 2015 · 796 · 2910.1016/j.nima.2015.04.065 ↗
13. Nucl. Instr. and Meth. A · 2015 · 796 · 3410.1016/j.nima.2015.04.023 ↗
14. 1999
15. Nucl. Instr. and Meth. A · 2007 · 583 · 13910.1016/j.nima.2007.08.207 ↗
16. 1994
17. Currents induced by electron motion10.1109/jrproc.1939.228757 ↗
18. Nucl. Instr. and Meth. A · 1993 · 326 · 398
19. Nucl. Instr. and Meth A · 2000 · 455 · 64510.1016/S0168-9002(00)00573-8 ↗