journal article·2014-03-01Open access

Melanin as an active layer in biosensors

Marina Piacenti da Silva, Jéssica Colnaghi Fernandes, Natália Biziak de Figueiredo, Mirko Congiu, Marcelo Mulato, Carlos Frederico de Oliveira Graeff

AIP Advances· Volume 4· Issue 3

Abstract

The development of pH sensors is of great interest due to its extensive application in several areas such as industrial processes, biochemistry and particularly medical diagnostics. In this study, the pH sensing properties of an extended gate field effect transistor (EGFET) based on melanin thin films as active layer are investigated and the physical mechanisms related to the device operation are discussed. Thin films were produced from different melanin precursors on indium tin oxide (ITO) and gold substrates and were investigated by Atomic Force Microscopy and Electrochemical Impedance Spectroscopy. Experiments were performed in the pH range from 2 to 12. EGFETs with melanin deposited on ITO and on gold substrates showed sensitivities ranging from 31.3 mV/pH to 48.9 mV/pH, depending on the melanin precursor and the substrate used. The pH detection is associated with specific binding sites in its structure, hydroxyl groups and quinone imine.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Advanced biosensing and bioanalysis techniques · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Sciences - UNESP 1 Department of Physics, , Bauru, SP, Brazil

University of São Paulo 2 Department of Physics, Faculty of Philosophy, Science and Letters at Ribeirão Preto, , Ribeirão Preto, SP, Brazil

References (30)

Show source-provided references
1. Appl. Phys. Lett · 2005 · 8710.1063/1.2084319 ↗
2. Sens. Actuators, B · 2003 · 91 · 18010.1016/S0925-4005(03)00161-8 ↗
3. Jpn. J. Appl. Phys., Part 1 · 2005 · 44 · 483810.1143/JJAP.44.4838 ↗
4. J. Mater. Sci · 2010 · 45 · 547810.1007/s10853-010-4603-4 ↗
5. IEEE Electron Device Lett. · 2012 · 33 · 162210.1109/LED.2012.2213794 ↗
6. Npg Asia Mater · 2012 · 4 · 110.1038/am.2012.42 ↗
7. Adv. Mater. · 2012 · 24 · 3410.1002/adma.201103334 ↗
8. Sensors · 2010 · 10 · 6110.3390/s100100061 ↗
9. Sensors · 2009 · 9 · 495510.3390/s90604955 ↗
10. Chem. Rev · 2008 · 108 · 82610.1021/cr068120y ↗
11. Adv. Mater · 2007 · 19 · 143910.1002/adma.200602043 ↗
12. Mater. Chem. Phys · 2000 · 63 · 1910.1016/S0254-0584(99)00184-4 ↗
13. Sens. Actuators, B · 2011 · 160 · 31210.1016/j.snb.2011.07.054 ↗
14. J. Sol-Gel Sci. Technol · 2009 · 52 · 31510.1007/s10971-009-2062-7 ↗
15. Adv. Colloid Interface Sci · 1996 · 69 · 3110.1016/S0001-8686(96)00307-7 ↗
16. IEEE Trans. Electron Devices · 1979 · 26 · 180510.1109/T-ED.1979.19690 ↗
17. Braz. J. Phys · 2006 · 36 · 47810.1590/S0103-97332006000300066 ↗
18. 1992
19. J. Am. Chem. Soc · 1978 · 100 · 392210.1021/ja00480a044 ↗
20. Biochim. Biophys. Acta, Gen. Subj · 1994 · 1199 · 27110.1016/0304-4165(94)90006-X ↗
21. Biomacromolecules · 2012 · 13 · 237910.1021/bm3006159 ↗
22. ACS Nano · 2013
23. J. Colloid Interface Sci · 2010 · 344 · 5410.1016/j.jcis.2009.12.052 ↗
24. Eur. Phys. J. E · 2009 · 28 · 28510.1140/epje/i2008-10437-9 ↗
25. Proceedings of the National Academy of Sciences of the United States of America · 2012 · 109 · 894310.1073/pnas.1119948109 ↗
26. Adv. Mater · 2008 · 20 · 353910.1002/adma.200703141 ↗
27. 2005
28. Colloids Surf. A · 2010 · 363 · 9210.1016/j.colsurfa.2010.04.020 ↗
29. Corrosion · 2001 · 57 · 74710.5006/1.3280607 ↗
30. Revista CES Medicina Veterinaria y Zootecnia · 2010 · 5 · 18