journal article·2026-01-28

A Multi-Ion Super-Nernstian Sensing Platform Based on MoS 2 Near-Sensor Amplifiers

Haojie Zhao, Jiawen Yan, Yixuan Zou, Bo Wang, Peng Li

Publisher page

Abstract

Measuring multiple ions in biofluids with high sensitivity and repeatability is crucial for human healthcare monitoring. Ion-sensitive field-effect transistors have gained widespread interest for their advantages of being label-free, low cost, fast response, and CMOS-compatible fabrication processes. However, they suffer from limited voltage sensitivity, known as the Nernst limit. Current strategies for breaking the Nernst limit face problems of low integration level or unstable responses. Herein, we propose an inverter-based near-sensor amplifier to address these restrictions and realize a multi-ion super-Nernstian sensing platform with an extended-gate configuration by coupling a molybdenum disulfide (MoS 2 ) inverter array with a multi-ion sensor chip. The high gain and stability of the MoS 2 inverter array are attributed to the excellent electrical properties of MoS 2, the low contact barrier between graphene and MoS 2, and the defect-free surface of h-BN. The platform demonstrates super-Nernstian detection of pH (469.1 mV/pH), Na + (472.7 mV/dec), K + (269.4 mV/dec), and Ca 2+ (221.2 mV/dec) levels within the biofluid range and exhibits stable long-term responses. Its practicality is further confirmed by selectivity investigations and artificial sweat analysis. The proposed platform is anticipated to play an important role in future point-of-care diagnostics, while this in situ amplification configuration is also expected to stimulate further near-sensor computing applications.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Analytical Chemistry and Sensors · 2D Materials and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments

Tsinghua University

Institute of Medical Equipment Science and Engineering

Huazhong University of Science and Technology

School of Mechanical Science and Engineering

Funding

National Natural Science Foundation of China

References (49)

Show source-provided references
1. 10.1111/1346-8138.1448910.1111/1346-8138.14489 ↗
2. 10.1056/nejmra140448910.1056/nejmra1404489 ↗
3. 10.1038/nature1652110.1038/nature16521 ↗
4. 10.1021/acsnano.6b0400510.1021/acsnano.6b04005 ↗
5. 10.1016/j.bios.2016.09.03810.1016/j.bios.2016.09.038 ↗
6. 10.3390/chemosensors1009036310.3390/chemosensors10090363 ↗
7. 10.1186/s12951-023-02153-110.1186/s12951-023-02153-1 ↗
8. 10.1016/j.trac.2018.11.02410.1016/j.trac.2018.11.024 ↗
9. 10.1016/j.bios.2017.07.01010.1016/j.bios.2017.07.010 ↗
10. 10.1016/j.snb.2014.08.05710.1016/j.snb.2014.08.057 ↗
11. 10.1021/acsami.3c0025710.1021/acsami.3c00257 ↗
12. 10.3390/bios1305051610.3390/bios13050516 ↗
13. 10.1016/S0254-0584(99)00184-410.1016/S0254-0584(99)00184-4 ↗
14. 10.1021/nn500914810.1021/nn5009148 ↗
15. 10.3390/s2112421310.3390/s21124213 ↗
16. 10.1063/1.368549710.1063/1.3685497 ↗
17. 10.1038/s41699-021-00273-610.1038/s41699-021-00273-6 ↗
18. 10.1021/acs.nanolett.0c0225910.1021/acs.nanolett.0c02259 ↗
19. 10.1002/smll.20250433210.1002/smll.202504332 ↗
20. 10.1016/j.electacta.2017.12.16310.1016/j.electacta.2017.12.163 ↗
21. 10.1038/s41928-024-01251-810.1038/s41928-024-01251-8 ↗
22. 10.1021/acs.nanolett.4c0118710.1021/acs.nanolett.4c01187 ↗
23. 10.1002/adma.20230738010.1002/adma.202307380 ↗
24. 10.1021/nn500992910.1021/nn5009929 ↗
25. 10.1021/acsnano.4c0431610.1021/acsnano.4c04316 ↗
26. 10.1038/s41586-025-08759-910.1038/s41586-025-08759-9 ↗
27. 10.1002/adma.20150387210.1002/adma.201503872 ↗
28. 10.1021/nn402954e10.1021/nn402954e ↗
29. 10.1016/j.apsusc.2022.15349810.1016/j.apsusc.2022.153498 ↗
30. 10.1021/acsami.3c0616110.1021/acsami.3c06161 ↗
31. 10.1002/adma.20170252210.1002/adma.201702522 ↗
32. 10.1116/1.124787410.1116/1.1247874 ↗
33. 10.1016/j.snb.2017.07.17310.1016/j.snb.2017.07.173 ↗
34. 10.1016/j.snb.2019.12703710.1016/j.snb.2019.127037 ↗
35. 10.1016/j.nanoen.2024.10975310.1016/j.nanoen.2024.109753 ↗
36. 10.1021/acssensors.9b0073110.1021/acssensors.9b00731 ↗
37. 10.1021/acsnano.0c0351510.1021/acsnano.0c03515 ↗
38. 10.1021/nn405213810.1021/nn4052138 ↗
39. 10.1039/c2nr30994g10.1039/c2nr30994g ↗
40. 10.1002/adma.20160275710.1002/adma.201602757 ↗
41. 10.1063/5.026893510.1063/5.0268935 ↗
42. 10.1021/acsnano.3c1322010.1021/acsnano.3c13220 ↗
43. 10.1063/1.491496810.1063/1.4914968 ↗
44. 10.1021/acsnano.7b0011310.1021/acsnano.7b00113 ↗
45. 10.1088/2053-1583/aa91a710.1088/2053-1583/aa91a7 ↗
46. 10.1088/2053-1583/aab67210.1088/2053-1583/aab672 ↗
47. 10.1088/2053-1583/3/3/03500410.1088/2053-1583/3/3/035004 ↗
48. 10.1039/c3an01672b10.1039/c3an01672b ↗
49. 10.1038/s41467-020-16979-y10.1038/s41467-020-16979-y ↗