Polarization Maintaining Fiber Temperature and Stress Gradient Sensitization Sensor Based on Semiconductor-Metal–Polymer Three-Layer Film Coating
Source abstract
Abstract
Increasing sensitivity, measuring points, and stability have always been the pursuit of sensors. ZnSe9:CO1 and Ag composite nano films were coated on polarization maintaining fiber (PMF). Then, the coated PMF was nested in capillary and hose which was encapsulated with polydimethylsiloxane (PDMS) and epoxy resin. The integrated capillary sensor and thermoplastic hose sensor were prepared. The gradient sensitization of various measurement parameters such as temperature, stress, and micro bending is realized. The temperature sensitivity is 1.49 nm/°C, the micro bending sensitivity is 1.72 nm/102 g, and the stress sensitivity is 6.27 nm/mε. The sensors maintain good linearity and instantaneous response while having high sensitivity. By adjusting the length of PMF, the number of troughs is increased in the same band range, and different troughs have different sensitivities, which solves the inherent problem of cross sensitivity and realizes multiparameter measurement. Capillary sensors are used for remote safe real-time monitoring of mechanical overheating, and hose sensors are used for real-time monitoring of bridge load and human joint bending. This work is of great significance to the extension of the application range of optical fiber sensor.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Fiber Optic Sensors · Advanced Sensor and Energy Harvesting Materials · Advanced Sensor Technologies Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Physics and Optoelectronics, Faculty of Science, Beijing University of Technology, Beijing 100124, China
Funding
National Natural Science Foundation of China · Beijing University of Technology
References (38)
Show source-provided references
1. 10.1016/j.optlastec.2019.01.01610.1016/j.optlastec.2019.01.016 ↗
2. 10.3390/s1908185110.3390/s19081851 ↗
3. 10.1016/j.ijleo.2016.04.05410.1016/j.ijleo.2016.04.054 ↗
4. 10.1364/OL.41573310.1364/OL.415733 ↗
5. 10.1007/s13320-013-0142-310.1007/s13320-013-0142-3 ↗
6. 10.3390/s1805160710.3390/s18051607 ↗
7. 10.3390/s1809311510.3390/s18093115 ↗
8. 10.1016/j.measurement.2018.11.03610.1016/j.measurement.2018.11.036 ↗
9. 10.1016/j.snb.2016.04.04510.1016/j.snb.2016.04.045 ↗
10. 10.1016/j.optlastec.2017.12.01310.1016/j.optlastec.2017.12.013 ↗
11. 10.1016/j.snb.2012.07.03910.1016/j.snb.2012.07.039 ↗
12. 10.1021/la301445h10.1021/la301445h ↗
13. 10.1021/acsami.5b0290110.1021/acsami.5b02901 ↗
14. 10.1021/acsami.6b1517210.1021/acsami.6b15172 ↗
15. 10.1007/s13320-018-0517-610.1007/s13320-018-0517-6 ↗
16. 10.1016/j.ijleo.2019.16400810.1016/j.ijleo.2019.164008 ↗
17. 10.1016/j.sna.2018.08.01310.1016/j.sna.2018.08.013 ↗
18. 10.3390/coatings1010097810.3390/coatings10100978 ↗
19. 10.1107/S160057671501798710.1107/S1600576715017987 ↗
20. 10.1039/D0NH00538J10.1039/D0NH00538J ↗
21. 10.1016/j.optmat.2020.11063310.1016/j.optmat.2020.110633 ↗
22. 10.1039/C8RA02466A10.1039/C8RA02466A ↗
23. 10.1021/acsami.1c1164910.1021/acsami.1c11649 ↗
24. 10.1109/JSEN.2016.251992710.1109/JSEN.2016.2519927 ↗
25. 10.1021/acssensors.9b0215510.1021/acssensors.9b02155 ↗
26. 10.1016/j.sna.2005.08.01910.1016/j.sna.2005.08.019 ↗
27. 10.1088/1555-6611/abc07010.1088/1555-6611/abc070 ↗
28. 10.1021/acs.analchem.6b0131410.1021/acs.analchem.6b01314 ↗
29. 10.1016/j.optcom.2016.05.03910.1016/j.optcom.2016.05.039 ↗
30. 10.3390/polym1109143310.3390/polym11091433 ↗
31. 10.1016/j.optcom.2013.09.02010.1016/j.optcom.2013.09.020 ↗
32. 10.1109/LPT.2014.237533710.1109/LPT.2014.2375337 ↗
33. 10.1016/j.snb.2014.03.06210.1016/j.snb.2014.03.062 ↗
34. 10.1063/1.316843510.1063/1.3168435 ↗
35. 10.1364/OE.26.01892010.1364/OE.26.018920 ↗
36. 10.1016/j.sna.2019.11179010.1016/j.sna.2019.111790 ↗
37. 10.1016/j.snb.2012.04.03510.1016/j.snb.2012.04.035 ↗
38. 10.1016/j.snb.2010.12.03710.1016/j.snb.2010.12.037 ↗