Molecular Sieve Based on a PMMA/ZIF-8 Bilayer for a CO-Tolerable H2 Sensor with Superior Sensing Performance
Source abstract
Abstract
Semiconductor sensors equipped with Pd catalysts are promising candidates as low-powered and miniaturized surveillance devices that are used to detect flammable hydrogen (H2) gas. However, the following issues remain unresolved: (i) a sluggish sensing speed at room temperature and (ii) deterioration of sensing performance caused by interfering gases, particularly, carbon monoxide (CO). Herein, a bilayer comprising poly(methyl methacrylate) (PMMA) and zeolitic imidazolate framework-8 (ZIF-8) is utilized as a molecular sieve for diode-type H2 sensors based on a Pd-decorated indium-gallium-zinc oxide film on a p-type silicon substrate. While the PMMA effectively blocks the penetration of CO gas molecules into the sensing entity, the ZIF-8 improves sensing performances by modifying the catalytic activity of Pd, which is preferable for splitting H2 and O2 molecules. Consequently, the bilayer-covered sensor achieves outstanding CO tolerance with superior sensing figures of merit (response/recovery times of <10 s and sensing response of >5000% at 1% H2).
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Analytical Chemistry and Sensors · ZnO doping and properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea
Funding
National Research Foundation of Korea · Gwangju Institute of Science and Technology
References (46)
Show source-provided references
1. 10.1021/cr050200z10.1021/cr050200z ↗
2. 10.1039/b704562j10.1039/b704562j ↗
3. 10.1021/cr800339k10.1021/cr800339k ↗
4. 10.1109/LED.2017.276523810.1109/LED.2017.2765238 ↗
5. 10.1002/smll.20170369110.1002/smll.201703691 ↗
6. 10.1039/C5NR06611E10.1039/C5NR06611E ↗
7. 10.1016/j.snb.2016.11.00510.1016/j.snb.2016.11.005 ↗
8. 10.1016/j.snb.2018.02.02510.1016/j.snb.2018.02.025 ↗
9. 10.1021/acsnano.5b0030210.1021/acsnano.5b00302 ↗
10. 10.3390/s11010082510.3390/s110100825 ↗
11. 10.1002/adma.20150289510.1002/adma.201502895 ↗
12. 10.1021/acsnano.7b0452910.1021/acsnano.7b04529 ↗
13. 10.1002/adma.20060157210.1002/adma.200601572 ↗
14. 10.1021/am503105s10.1021/am503105s ↗
15. 10.1021/acsami.8b1544510.1021/acsami.8b15445 ↗
16. 10.1063/1.192907510.1063/1.1929075 ↗
17. 10.1021/acsami.7b0764110.1021/acsami.7b07641 ↗
18. 10.13182/FST88-A2520210.13182/FST88-A25202 ↗
19. 10.1016/j.cap.2010.12.02410.1016/j.cap.2010.12.024 ↗
20. 10.1016/j.ijhydene.2012.05.13110.1016/j.ijhydene.2012.05.131 ↗
21. 10.1016/j.jpowsour.2006.12.01210.1016/j.jpowsour.2006.12.012 ↗
22. 10.1038/s41563-019-0325-410.1038/s41563-019-0325-4 ↗
23. 10.1021/am507364510.1021/am5073645 ↗
24. 10.1039/C7GC02260C10.1039/C7GC02260C ↗
25. 10.1039/C8TA00612A10.1039/C8TA00612A ↗
26. 10.1021/cr200324t10.1021/cr200324t ↗
27. 10.1021/acsami.8b1256910.1021/acsami.8b12569 ↗
28. 10.1021/acssensors.5b0023610.1021/acssensors.5b00236 ↗
29. 10.1021/nl050082v10.1021/nl050082v ↗
30. 10.1016/j.sna.2017.10.02110.1016/j.sna.2017.10.021 ↗
31. 10.1002/adma.20150382510.1002/adma.201503825 ↗
32. 10.1039/C8NR06701E10.1039/C8NR06701E ↗
33. 2009
34. Chandran S. · Pharmazie · 2007 · 62 · 4
35. 10.1002/polb.1988.09026050710.1002/polb.1988.090260507 ↗
36. 10.1006/jcat.2000.313610.1006/jcat.2000.3136 ↗
37. 10.1021/jp064507t10.1021/jp064507t ↗
38. 10.1021/jp068997110.1021/jp0689971 ↗
39. 10.1038/nmat122310.1038/nmat1223 ↗
40. 10.1007/s40820-017-0129-510.1007/s40820-017-0129-5 ↗
41. 10.1021/acsnano.9b0248110.1021/acsnano.9b02481 ↗
42. 10.1039/C9NR01975H10.1039/C9NR01975H ↗
43. 10.1126/sciadv.160255710.1126/sciadv.1602557 ↗
44. 10.1021/acsami.8b0158310.1021/acsami.8b01583 ↗
45. 10.1021/acsnano.8b0058010.1021/acsnano.8b00580 ↗
46. 10.1021/nn204009m10.1021/nn204009m ↗