journal article·2016-08-10

Molecularly Imprinted Polymer (MIP) Film with Improved Surface Area Developed by Using Metal–Organic Framework (MOF) for Sensitive Lipocalin (NGAL) Determination

Zofia Iskierko, Piyush Sindhu Sharma, Daniel Prochowicz, Krzysztof Fronc, Francis D’Souza, Diana Toczydłowska, Filip Stefaniak, Krzysztof Noworyta

Publisher page

Abstract

Electropolymerizable functional and cross-linking monomers were used to prepare conducting molecularly imprinted polymer film with improved surface area with the help of a sacrificial metal-organic framework (MOF). Subsequent dissolution of the MOF layer resulted in a surface developed MIP film. This surface enlargement increased the analyte accessibility to imprinted molecular cavities. Application of the porous MIP film as a recognition unit of an extended-gate field effect transistor (EG-FET) chemosensor effectively enhanced analytical current signals of determination of recombinant human neutrophil gelatinase-associated lipocalin (NGAL).
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Molecular Sensors and Ion Detection · Electrochemical sensors and biosensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland

Institute of Physics, Polish Academy of Sciences, 32/46 Al. Lotników, 02-668 Warsaw, Poland

Department of Chemistry, University of North Texas, Denton, Texas 76203-5017, United States

Laboratory of Bioinformatics and Protein Engineering, International Institute of Molecular and Cell Biology in Warsaw, Ks. Trojdena 4, 02-109 Warsaw, Poland

Funding

Ministerstwo Nauki i Szkolnictwa Wyzszego · European Research Council · Narodowe Centrum Nauki · Fundacja na rzecz Nauki Polskiej

References (30)

Show source-provided references
1. 10.1016/j.progpolymsci.2013.10.00210.1016/j.progpolymsci.2013.10.002 ↗
2. 10.1016/j.aca.2005.06.06710.1016/j.aca.2005.06.067 ↗
3. 10.1002/adfm.20120132810.1002/adfm.201201328 ↗
4. 10.1016/j.trac.2013.07.00610.1016/j.trac.2013.07.006 ↗
5. 10.1002/adfm.20130011310.1002/adfm.201300113 ↗
6. 10.1016/j.bios.2012.11.00210.1016/j.bios.2012.11.002 ↗
7. 10.1002/adma.20080359710.1002/adma.200803597 ↗
8. 10.1074/jbc.M41319220010.1074/jbc.M413192200 ↗
9. 10.1016/S0140-6736(05)74811-X10.1016/S0140-6736(05)74811-X ↗
10. 10.1007/s10157-014-0952-710.1007/s10157-014-0952-7 ↗
11. 10.1002/adfm.20120237010.1002/adfm.201202370 ↗
12. 10.1007/s00216-011-5696-610.1007/s00216-011-5696-6 ↗
13. 10.1039/b915717d10.1039/b915717d ↗
14. 10.1021/cr200324t10.1021/cr200324t ↗
15. 10.1002/anie.20140295010.1002/anie.201402950 ↗
16. 10.1016/j.bios.2011.07.02610.1016/j.bios.2011.07.026 ↗
17. 10.1021/cr200167v10.1021/cr200167v ↗
18. 10.1016/j.trac.2014.02.01210.1016/j.trac.2014.02.012 ↗
19. 10.1021/ja076210u10.1021/ja076210u ↗
20. 10.1021/ja070120810.1021/ja0701208 ↗
21. 10.1016/j.micromeso.2013.03.02510.1016/j.micromeso.2013.03.025 ↗
22. 10.1093/nar/gkr116210.1093/nar/gkr1162 ↗
23. 10.1021/ci100241y10.1021/ci100241y ↗
24. 10.1002/jcc.2133410.1002/jcc.21334 ↗
25. 10.1016/S0959-440X(01)00278-010.1016/S0959-440X(01)00278-0 ↗
26. 10.1039/c3tb00257h10.1039/c3tb00257h ↗
27. 10.1039/C5CY01181G10.1039/C5CY01181G ↗
28. 10.1002/bip.36030131010.1002/bip.360301310 ↗
29. 10.1016/j.electacta.2016.03.09210.1016/j.electacta.2016.03.092 ↗
30. Lvovich, V. F.Impedance Spectroscopy. Applications to Electrochemical and Dielectric Phenomena;John Wiley & Sons:Hoboken, NJ, 2012; pp152–157.10.1002/9781118164075 ↗