article·2007-01-01Open access

Micro area residual stress analysis of ferroelectric films by means of XRD2 technique

Jiang Jian-qing

Open full text

Abstract

Based on the X-ray diffractometer attached with a rectangular planar detector and long pinhole collimator,a method of residual stress measurement in micro area of radio-frequency magnetron sputtering Pb(Zr,Ti)O3 film deposited on Pt/Ti/SiO2/Si substrate was proposed,that is,the characterization of residual stress in film was investigated according to analysis on the deformation of diffraction core.The stress measurement results showed that PZT film deposited on Pt/Si substrate is in tension,and a residual stress distribution with fluctuation was found in the film.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Engineering Applied Research · Acoustic Wave Resonator Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.