journal article·2026-06-20Open access

Vein Graft Preservation During Coronary Artery Bypass Graft Surgery: Operative Techniques, Biomaterials and Advances from Tissue Engineering

Benedetto Ferraresi, Antonio Nenna, Mohamad Jawabra, Diletta Corrado, Filippo Barberi, Carmelo Dominici, Giovanni Casali, Lucia Barbieri, Gabriele Tumminello, Stefano Carugo, Massimo Chello, Mario Lusini

Abstract

The failure of saphenous vein grafts following coronary artery bypass grafting (CABG) remains a significant issue, as it limits the durability of vein-based surgical revascularisation compared to arterial conduits. Venous graft disease is a dynamic process that begins early in the perioperative period as a consequence of harvesting trauma, ex vivo preservation, and the sudden exposure of the conduit to the arterial haemodynamic environment. This narrative review summarises the available evidence on local graft protection strategies, focusing on intraoperative and perioperative approaches aimed at preserving endothelial integrity, attenuating initial inflammation, and limiting maladaptive remodelling. Specifically, the review analyses the role of endothelium-protective preservation solutions, external support devices, biodegradable drug-eluting biomaterials, and locally targeted RNA therapies. Preclinical and early clinical evidence suggests that local graft protection is biologically plausible and may reduce intimal hyperplasia, luminal irregularity and adverse graft remodelling. However, its impact on long-term clinical outcomes remains uncertain. An integrated approach combining harvest optimisation, conduit preservation, mechanical support, and local delivery of drugs or regulatory molecules may represent a promising framework for improving vein graft biology; however, its ability to translate into durable patency gains and improved clinical outcomes after CABG requires further clinical validation.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cardiac and Coronary Surgery Techniques · Coronary Interventions and Diagnostics · Electrospun Nanofibers in Biomedical Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Cardiac Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo 200, 00128 Rome, Italy

Department of Cardio-Thoracic-Vascular Diseases, Foundation IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Via Francesco Sforza 28, 20122 Milan, Italy

Cardiac Surgery, Azienda Ospedaliero Universitaria Maggiore della Carità di Novara, Corso Mazzini 18, 28100 Novara, Italy

Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy

References (31)

Show source-provided references
1. The short- and long-term outcomes of percutaneous intervention with drug-eluting stent vs bare-metal stent in saphenous vein graft disease: An updated meta-analysis of all randomized clinical trials10.1002/clc.22908 ↗
2. Saphenous Vein Graft Failure: From Pathophysiology to Prevention and Treatment Strategies10.1161/CIRCULATIONAHA.120.052163 ↗
3. Arterial blood pressure and vascular function in human saphenous vein10.1177/0267659114540021 ↗
4. Outcomes of No-Touch Vs Conventionally Harvested Saphenous Veins for Coronary Artery Bypass Surgery: A Meta-Analysis of Randomized Trials10.1093/ejcts/ezaf297 ↗
5. Human Saphenous Vein Response to Trans-wall Oxygen Gradients in a Novel Ex Vivo Conditioning Platform10.1007/s10439-015-1434-0 ↗
6. Dell’Aquila, M., Prapas, S., Falco, G., Abdalla, S., Tejada, B., Challagalla, M., Condello, I., Newman, J., Jarral, O., and Pupovac, S. (2026). Saphenous vein graft and nitric oxide: Strategies to prevent graft failure and enhance patency in coronary artery bypass grafting. Front. Cardiovasc. Med., 12.10.3389/fcvm.2025.1745260 ↗
7. Underlying mechanisms of saphenous vein graft stenosis after coronary artery bypass caused by clipping of the side branches: An experimental study10.21037/jtd-22-235 ↗
8. Intraoperative storage of saphenous vein grafts in coronary artery bypass grafting10.1080/17434440.2019.1682996 ↗
9. Biodegradable external wrapping promotes favorable adaptation in an ovine vein graft model10.1016/j.actbio.2022.08.029 ↗
10. Time-dependently slow-released multiple-drug eluting external sheath for efficient long-term inhibition of saphenous vein graft failure10.1016/j.jconrel.2018.12.001 ↗
11. External stenting and disease progression in saphenous vein grafts two years after coronary artery bypass grafting: A multicenter randomized trial10.1016/j.jtcvs.2021.03.120 ↗
12. Outcomes following revascularization with radial artery bypass grafts: Insights from the PREVENT-IV trial10.1016/j.ahj.2020.08.001 ↗
13. Gene therapy with antisense oligonucleotides silencing c-myc reduces neointima formation and vessel wall thickness in a mouse model of vein graft disease10.1016/j.yexmp.2018.05.003 ↗
14. Intra-operative and post-operative management of conduits for coronary artery bypass grafting: A clinical consensus statement of the European Society of Cardiology Working Group on Cardiovascular Surgery and the European Association for Cardio-Thoracic Surgery Coronary Task Force10.1093/ejcts/ezae400 ↗
15. Administration of perivascular cyanoacrylate for the prevention of cellular damage in saphenous vein grafts: An experimental model10.5830/CVJA-2015-078 ↗
16. Korkmaz-Icöz, S., Ballikaya, B., Soethoff, J., Kraft, P., Sayour, A.A., Radovits, T., Loganathan, S., Karck, M., Szabó, G., and Veres, G. (2021). Graft Preservation Solution DuraGraft® Alleviates Vascular Dysfunction Following In Vitro Ischemia/Reperfusion Injury in Rats. Pharmaceuticals, 14.10.3390/ph14101028 ↗
17. Propensity-matched analysis of the impact of saphenous vein graft external stenting on clinical outcomes in coronary bypass surgery: The RESTART study10.1016/j.xjon.2025.09.048 ↗
18. Venous external support enhanced coronary artery bypass grafting: A multicentric cohort experience10.1186/s13019-025-03670-w ↗
19. Vein Graft Preservation Solutions, Patency, and Outcomes After Coronary Artery Bypass Graft Surgery: Follow-up From the PREVENT IV Randomized Clinical Trial10.1001/jamasurg.2014.87 ↗
20. ‘No-touch’ or ‘soft-touch’ vein graft harvesting for CABG10.1007/s12055-024-01846-y ↗
21. Szalkiewicz, P., Emmert, M.Y., Heinisch, P.P., Arnold, Z., Crailsheim, I., Mach, M., Aschacher, T., Grabenwöger, M., and Winkler, B. (2022). Graft preservation confers myocardial protection during coronary artery bypass grafting. Front. Cardiovasc. Med., 9.10.3389/fcvm.2022.922357 ↗
22. New strategy of using double-network hydrogel extravascular stent for preventing venous graft restenosis after coronary artery bypass grafting10.1177/02676591221099813 ↗
23. Poly (ɛ-Caprolactone-co-L,L-Lactide) Vascular External Sheath Carrying Prednisone for Improving Patency Rate of the Vein Graft10.1089/ten.tea.2021.0118 ↗
24. Administration of a new nano delivery system coated with Tirofiban to prevent early thrombosis of vein graft10.1177/02676591231163014 ↗
25. The PRoject of Ex-vivo Vein graft ENgineering via Transfection IV (PREVENT IV) trial10.1016/j.ahj.2005.05.021 ↗
26. McQueen, L.W., Ladak, S.S., Layton, G.R., Wozniak, M., Solomon, C., El-Dean, Z., Murphy, G.J., and Zakkar, M. (2024). Spatial Transcriptomic Profiling of Human Saphenous Vein Exposed to Ex Vivo Arterial Haemodynamics—Implications for Coronary Artery Bypass Graft Patency and Vein Graft Disease. Int. J. Mol. Sci., 25.10.3390/ijms251910368 ↗
27. Upregulation of miR-126-3p promotes human saphenous vein endothelial cell proliferation in vitro and prevents vein graft neointimal formation ex vivo and in vivo10.18632/oncotarget.22365 ↗
28. Blockade of YAP Mechanoactivation Prevents Neointima Formation and Adverse Remodeling in Arterialized Vein Grafts10.1161/JAHA.124.037531 ↗
29. NF-κB inhibition prevents acute shear stress-induced inflammation in the saphenous vein graft endothelium10.1038/s41598-020-71781-6 ↗
30. Montelione, N., Catanese, V., Nenna, A., Gabellini, T., Ferrisi, C., Paolini, J., Ciolli, A., Barillà, D., Loreni, F., and Chello, M. (2024). External Scaffold for Venous Graft to Treat Chronic Limb-Threatening Ischemia: Results of the FRAME Vascular Support. J. Clin. Med., 13.10.3390/jcm13072095 ↗
31. Preventing treatment failures in coronary artery disease: What can we learn from the biology of in-stent restenosis, vein graft failure and internal thoracic arteries?10.1093/cvr/cvz214 ↗