Numerical Simulation of Dynamic Degradation and Fatigue Damage of Degradable Zinc Alloy Stents
Source abstract
Abstract
Current research on the fatigue properties of degradable zinc alloy stents has not yet considered the issue of the fatigue life changing with material properties during the dynamic degradation process. Therefore, in this paper, we established a fatigue damage algorithm to study the fatigue problem affected by the changing of material properties during the dynamic degradation process of the stent under the action of pulsating cyclic loading. Three models: the dynamic degradation model, the dynamic degradation model under pulsating cyclic loading, and the coupled model of fatigue damage and dynamic degradation, were developed to verify the effect of fatigue damage on stent life. The results show that fatigue damage leads to a deeper degree of inhomogeneous degradation of the stent, which affects the service life of the stent. Fatigue damage is a factor that cannot be ignored. Therefore, when studying the mechanical properties and lifetime of degradable stents, incorporating fatigue damage into the study can help more accurately assess the lifetime of the stents.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Advanced Welding Techniques Analysis · Aluminum Alloy Microstructure Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
Funding
National Key Research and Development Program of China · National Natural Science Foundation of China · Joint Program of Beijing Municipal—Beijing Natural Science Foundation
References (41)
Show source-provided references
1. Percutaneous coronary intervention for stable coronary artery disease10.1016/j.jacc.2008.05.048 ↗
2. Research on elastic recoil and restoration of vessel pulsatility of Zn-Cu biodegradable coronary stents10.1515/bmt-2019-0025 ↗
3. Processing of a Novel Zn Alloy Micro-Tube for Biodegradable Vascular Stent Application10.1016/j.jmst.2016.08.008 ↗
4. Research on a Zn-Cu alloy as a biodegradable material for potential vascular stents application10.1016/j.msec.2016.06.082 ↗
5. Cockerill, I., Su, Y.C., Sinha, S., Qin, Y.-X., Zheng, Y.F., Young, M.L., and Zhu, D.H. (2020). Porous zinc scaffolds for bone tissue engineering applications: A novel additive manufacturing and casting approach. Mater. Sci. Eng. C-Mater. Biol. Appl., 110.10.1016/j.msec.2020.110738 ↗
6. Shojaei, S., Shahgholi, M., and Ksrimipour, A. (2023). The effects of atomic percentage and size of Zinc nanoparticles, and atomic porosity on thermal and mechanical properties of reinforced calcium phosphate cement by molecular dynamics simulation. J. Mech. Behav. Biomed. Mater., 141.10.1016/j.jmbbm.2023.105785 ↗
7. A Biomimetic Zinc Alloy Scaffold Coated with Brushite for Enhanced Cranial Bone Regeneration10.1021/acsbiomaterials.9b01895 ↗
8. Biocompatibility of bio-Mg-Zn alloy within bone with heart, liver, kidney and spleen10.1007/s11434-009-0080-z ↗
9. Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation10.1016/j.ijcard.2007.12.067 ↗
10. The incidence and clinical impact of stent strut fractures developed after drug-eluting stent implantation10.1016/j.ijcard.2007.02.033 ↗
11. Incidence and Clinical Impact of Stent Fracture After the Nobori Biolimus-Eluting Stent Implantation10.1161/JAHA.113.000703 ↗
12. Incidence of coronary drug-eluting stent fracture: A systematic review and meta-analysis10.3389/fcvm.2022.925912 ↗
13. Effects of macro-scale corrosion damage feature on fatigue crack initiation and fatigue behavior10.1016/j.ijfatigue.2017.05.028 ↗
14. A numerical corrosion-fatigue model for biodegradable Mg alloy stents10.1016/j.actbio.2019.08.004 ↗
15. Continuum damage model for bioresorbable magnesium alloy devices—Application to coronary stents10.1016/j.jmbbm.2010.11.003 ↗
16. Corrosion fatigue behaviors of two biomedical Mg alloys-AZ91D and WE43-In simulated body fluid10.1016/j.actbio.2010.07.026 ↗
17. Fatigue behavior of modified ZK60 magnesium alloy after pre-corrosion under stress-controlled loading10.1016/j.engfracmech.2021.108187 ↗
18. Corrosion fatigue fracture of magnesium alloys in bioimplant applications: A review10.1016/j.engfracmech.2014.08.009 ↗
19. Fatigue behaviour of monotectoid-based Zn–Al–Cu alloys in 3.5% NaCl and 1% HCl solutions10.1016/j.matchar.2004.05.008 ↗
20. Corrosion fatigue behavior of additively manufactured biodegradable porous zinc10.1016/j.actbio.2020.02.001 ↗
21. Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis10.1007/s10439-015-1447-8 ↗
22. Crack extension identification based on distributed fiber sensing measurement and optimized support vector regression10.1016/j.oceaneng.2021.110515 ↗
23. Banno, Y., Kinoshita, K., and Barsoum, Z. Life extension analysis considering crack opening-closing behavior in HFMI-treated welds. Weld World, 2023.10.1007/s40194-023-01583-7 ↗
24. Providing a model for Csf according to pool boiling convection heat transfer of water/ferrous oxide nanofluid using sensitivity analysis10.1108/HFF-01-2019-0009 ↗
25. Statistical estimation the thermal conductivity of MWCNTs-SiO2/Water-EG nanofluid using the ridge regression method10.1016/j.physa.2019.122782 ↗
26. Ubiquitiformal Crack Extension in Quasi-Brittle Materials10.1007/s10338-020-00171-2 ↗
27. A Computational Modelling of the Mechanical Performance of a Bioabsorbable Stent Undergoing Cyclic Loading10.1016/j.prostr.2019.07.013 ↗
28. Finite element analysis of balloon-expandable coronary stent deployment: Influence of angioplasty balloon configuration10.1002/cnm.2557 ↗
29. Fatigue behaviour of Nitinol peripheral stents: The role of plaque shape studied with computational structural analyses10.1016/j.medengphy.2014.03.006 ↗
30. Zhang, H.B., Du, T.M., Chen, S.L., Liu, Y., Yang, Y.J., Hou, Q.W., and Qiao, A.K. (2022). Finite Element Analysis of the Non-Uniform Degradation of Biodegradable Vascular Stents. J. Funct. Biomater., 13.10.3390/jfb13030152 ↗
31. A simple model for slow strain rate and constant load corrosion tests of austenitic stainless steel in acid aqueous solution containing sodium chloride10.1016/j.corsci.2008.07.020 ↗
32. A Critical Review of the Stress Corrosion Cracking (SCC) of Magnesium Alloys10.1002/adem.200500071 ↗
33. A corrosion model for bioabsorbable metallic stents10.1016/j.actbio.2011.05.032 ↗
34. Fatigue life prediction of high-speed train bearings based on the generalized linear cumulative damage theory10.1111/ffe.13984 ↗
35. Fatigue properties of zinc–aluminium alloys in 3.5% NaCl and 1% HCl solutions10.1016/S0142-1123(03)00091-4 ↗
36. Fatigue crack growth behavior of surface crack in rails10.1016/j.proeng.2010.03.093 ↗
37. Fatigue crack paths in coarse-grained magnesium10.1111/j.1460-2695.2004.00832.x ↗
38. Computational Assessment of Stent Durability Using Fatigue to Fracture Approach10.1115/1.4027687 ↗
39. Corrosion and corrosion-fatigue behavior of magnesium metal matrix composites for bio-implant applications: A review10.1016/j.jma.2023.04.010 ↗
40. The effect of sensitization and fatigue loading frequency on corrosion fatigue of AA5083-H13110.1016/j.ijfatigue.2019.02.044 ↗
41. Effects of potential and loading frequency on corrosion fatigue behavior of 2205 duplex stainless steel10.5006/1.3280684 ↗