journal article·2023-03-07Open access

Microscopic Inspection of the Adhesive Interface of Composite Onlays after Cementation on Low Loading: An In Vitro Study

Tiago Magalhães, Rita Fidalgo-Pereira, Orlanda Torres, Óscar Carvalho, Filipe S. Silva, Bruno Henriques, Mutlu Özcan, Júlio C. M. Souza

Abstract

Purpose: This study aimed to assess the layer thickness and microstructure of traditional resin-matrix cements and flowable resin-matrix composites at dentin and enamel to composite onlay interfaces after cementation on low loading magnitude. Materials and Methods: Twenty teeth were prepared and conditioned with an adhesive system for restoration with resin-matrix composite onlays manufactured by CAD-CAM. On cementation, tooth-to-onlay assemblies were distributed into four groups, including two traditional resin-matrix cements (groups M and B), one flowable resin-matrix composite (group G), and one thermally induced flowable composite (group V). After the cementation procedure, assemblies were cross-sectioned for inspection by optical microscopy at different magnification up to ×1000. Results: The layer thickness of resin-matrix cementation showed the highest mean values at around 405 µm for a traditional resin-matrix cement (group B). The thermally induced flowable resin-matrix composites showed the lowest layer thickness values. The resin-matrix layer thickness revealed statistical differences between traditional resin cement (groups M and B) and flowable resin-matrix composites (groups V and G) (p < 0.05). However, the groups of flowable resin-matrix composites did not reveal statistical differences (p < 0.05). The thickness of the adhesive system layer at around 7 µm and 12 µm was lower at the interfaces with flowable resin-matrix composites when compared to the adhesive layer at resin-matrix cements, which ranged from 12 µm up to 40 µm. Conclusions: The flowable resin-matrix composites showed adequate flowing even though the loading on cementation was performed at low magnitude. Nevertheless, significant variation in thickness of the cementation layer was noticed for flowable resin-matrix composites and traditional resin-matrix cements that can occur in chair-side procedures due to the clinical sensitivity and differences in rheological properties of the materials.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra PRD, Portugal

Center for Interdisciplinary Research in Health (CIIS), Faculty of Dental Medicine (FMD), Universidade Católica Portuguesa (UCP), 3504-505 Viseu, Portugal

Oral Pathology and Rehabilitation Research Unit (UNIPRO), University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra PRD, Portugal

Centre for MicroElectromechanical Systems (CMEMS-UMINHO), Campus Azurém, University of Minho, 4800-058 Guimarães, Portugal

LABBELS Associate Laboratory, University of Minho, 4710-057 Braga, Portugal

Ceramic and Composite Materials Research Group (CERMAT), Department of Mechanical Engineering (EMC), Federal University of Santa Catarina (UFSC), Florianopolis 88040-900, Brazil

Division of Dental Biomaterials, Center of Dental Medicine, Clinic of Reconstructive Dentistry, University of Zurich, 8032 Zurich, Switzerland

Funding

Portuguese Foundation for Science and Technology (FCT) · Project LaserMULTICER

References (52)

Show source-provided references
1. Comparison of CAD-CAM and traditional chairside processing of 4-unit interim prostheses with and without cantilevers: Mechanics, fracture behavior, and finite element analysis10.1016/j.prosdent.2020.11.007 ↗
2. Mechanical integrity of cement-and screw-retained zirconium-lithium silicate glass-ceramic crowns to Morse taper implants10.1016/j.prosdent.2018.01.028 ↗
3. Volumetric and dimensional accuracy assessment of CAD-CAM–manufactured dental prostheses from different materials10.1016/j.prosdent.2021.05.024 ↗
4. Effect of Chairside CAD/CAM Restoration Type on Marginal Fit Accuracy: A Comparison of Crown, Inlay and Onlay Restorations
5. The influence of zirconia veneer thickness on the degree of conversion of resin-matrix cements: An integrative review10.1007/s00784-021-03904-w ↗
6. Luting of inlays, onlays, and overlays with preheated restorative composite resin does not prevent seating accuracy
7. Chairside CAD/CAM Composite Onlays for the Restoration of Primary Molars10.17796/1053-4625-42.5.5 ↗
8. Restoration of Morphologically Compromised and Endodontically Treated Molars10.11607/ijp.2768 ↗
9. Marginal and internal fit of CAD-CAM inlay/onlay restorations: A systematic review of in vitro studies10.1016/j.prosdent.2018.06.006 ↗
10. The Use of CAD/CAM in Dentistry10.1016/j.cden.2011.02.011 ↗
11. Understanding dental CAD/CAM for restorations--dental milling machines from a mechanical engineering viewpoint. Part B: Labside milling machines
12. Ceramic materials in dentistry: Historical evolution and current practice10.1111/j.1834-7819.2010.01299.x ↗
13. Resin-composite blocks for dental CAD/CAM applications10.1177/0022034514553976 ↗
14. Establishing a suitable surface roughness for lithium disilicate implant abutments under laboratory conditions: A morphologic SEM and profilometric pilot study
15. One-year clinical performance of lithium disilicate versus resin composite CAD/CAM onlays10.1007/s10266-020-00539-3 ↗
16. Micro-Computed Tomography Analysis of Fit of Ceramic Inlays Produced with Dif-ferent CAD Software Programs
17. A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes10.1016/j.prosdent.2014.05.012 ↗
18. Mechanical properties and internal fit of 4 CAD-CAM block materials10.1016/j.prosdent.2017.03.001 ↗
19. Challenges of the Direct Filling Technique, Adoption of CAD/CAM Techniques, and Attitudes Toward 3D Printing for Restorative Treatments Among Finnish Dentists10.11607/ijp.6343 ↗
20. A comparison of the marginal adaptation of composite overlays fabricated with silicone and an intraoral scanner
21. The Effect of Resin Bonding on Long-Term Success of High-Strength Ceramics10.1177/0022034517729134 ↗
22. The effect of space setting values and restorative block materials on the bonding of metal-free CAD/CAM onlay restorations10.4012/dmj.2020-293 ↗
23. Bonding state of metal-free CAD/CAM onlay restoration after cyclic loading with and without immediate dentin sealing10.4012/dmj.2016-289 ↗
24. Effect of immediate dentin sealing applications on bonding of CAD/CAM ceramic onlay restoration10.4012/dmj.2017-377 ↗
25. Effect of differences in the type of restoration and adhesive resin cement system on the bonding of CAD/CAM ceramic restorations10.4012/dmj.2019-308 ↗
26. The resin-matrix cement layer thickness resultant from the intracanal fitting of teeth root canal posts: An integrative review10.1007/s00784-021-04070-9 ↗
27. Adhesion/cementation to zirconia and other non-silicate ceramics: Where are we now?10.1016/j.dental.2010.10.022 ↗
28. Effect of surface conditioning methods on the bond strength of luting cement to ceramics10.1016/S0109-5641(03)00019-8 ↗
29. Characterization of Inorganic Filler Content, Mechanical Properties, and Light Transmission of Bulk-fill Resin Composites10.2341/16-024-L ↗
30. Evaluation of degree of conversion and the effect of thermal aging on the color stability of resin cements and flowable composite
31. Evaluation of marginal leakage after mechanical fatigue cycling of composite inlays luted with different cements
32. Abrasive and sliding wear of resin composites for dental restorations10.1016/j.triboint.2016.05.035 ↗
33. Mechanical Strength and Wear of Dental Glass-Ionomer and Resin Composites Affected by Porosity and Chemical Composition10.1007/s40735-015-0025-9 ↗
34. An integrative review on the toxicity of Bisphenol A (BPA) released from resin composites used in dentistry10.1002/jbm.b.34843 ↗
35. Resin composite—State of the art10.1016/j.dental.2010.10.020 ↗
36. Surface modification of glass fiber-reinforced composite posts to enhance their bond strength to resin-matrix cements: An integrative review10.1007/s00784-021-04221-y ↗
37. Accuracy of inlay and onlay restorations based on 3D printing or milling technique—A pilot study
38. Marginal and internal fit of nano-composite CAD/CAM restorations10.5395/rde.2016.41.1.37 ↗
39. The marginal discrepancy of lithium disilicate onlays: Computer-aided design versus press10.4103/JCD.JCD_31_19 ↗
40. Pre-heating of high-viscosity bulk-fill resin composites: Effects on shrinkage force and monomer conversion10.1016/j.jdent.2015.07.014 ↗
41. Microtensile Bond Strength of a Resin Cement to Silica-Based and Y-TZP Ceramics Using Different Surface Treatments10.1111/jopr.12622 ↗
42. Effects of Different Surface Treatments on Bond Strength of Resin Cement to Machined Pure Titanium
43. Temporary Implant-Supported Single Crowns Using Titanium Base Abutments: An In Vitro Study on Bonding Stability and Pull-out Forces10.11607/ijp.6778 ↗
44. Effect of airborne-particle abrasion of a titanium base abutment on the stability of the bonded interface and retention forces of crowns after artificial aging10.1016/j.prosdent.2020.06.013 ↗
45. Fatigue Failure Load of Lithium Disilicate Restorations Cemented on a Chairside Titanium-Base10.1111/jopr.12911 ↗
46. Fracture Strength of Monolithic All-Ceramic Crowns on Titanium Implant Abutments10.11607/jomi.4601 ↗
47. Laser surface structuring of Ti6Al4V substrates for adhesion enhancement in Ti6Al4V-PEEK joints10.1016/j.msec.2017.04.157 ↗
48. Tribocorrosion Behavior of Ti6Al4V Coated with a Bio-absorbable Polymer for Biomedical Applications10.1007/s40735-015-0029-5 ↗
49. Microtensile bond strength and interfacial properties of self-etching and self-adhesive resin cements used to lute composite onlays under different seating forces
50. Influence of immediate dentin sealing and interim cementation on the adhesion of indirect restorations with dual-polymerizing resin cement10.1016/j.prosdent.2018.02.001 ↗
51. Effects of Finger Pressure Applied by Dentists during Cementation of All-Ceramic Crowns10.1055/s-0039-1697857 ↗
52. Cement Thickness of Inlay Restorations Made of Lithium Disilicate, Polymer-Infiltrated Ceramic and Nano-Ceramic CAD/CAM Materials Evaluated Using 3D X-Ray Micro-Computed Tomography10.1111/jopr.12521 ↗