Surface Analysis of Orthodontic Mini-Implants after Their Clinical Use

Tamara Rahela Ioana, Filip George Boeru, Iulian Antoniac, Ioana Mitruț, Ionela Elisabeta Staicu, Anne Marie Rauten, Willi Andrei Uriciuc, Horia Octavian Manolea

Abstract

Temporary anchorage devices (TADs) are orthodontic mini-implants with remarkable characteristics that, once inserted, present mechanical retention (primary stability) without the process of bone osseointegration. However, interaction with the biological environment may cause changes in the morphology of the external surface of dental TADs. In this study, we used 17 TADs made of aluminum–vanadium titanium alloy, produced by two companies, which were analyzed through optical microscopy after being removed from the patients during orthodontic treatment. We evaluated the changes that appeared on the TADs’ surfaces after their use in the biological environment, depending on the morphological area in which they were inserted. In our study, we found changes in the morphology of the implant surface, and especially deposits of biological material in all study groups. On all samples examined after clinical use, regardless of the period of use, corrosion surfaces in different locations were observed. Our obtained results support the idea that the biological environment is aggressive for mini-implant structures, always producing changes to their surface during their clinical use.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Private Practice “Embrace”, 200618, Craiova, Romania

Faculty of Material Science and Engineering, National University of Science and Technology Politehnica Bucharest, 060042 Bucharest, Romania

Department of Dental Technology, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Department of Oral Rehabilitation, Faculty of Dental Medicine, “Iuliu-Hațieganu” University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania

Department of Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Funding

University of Medicine and Pharmacy of Craiova

References (57)

Show source-provided references
1. Influence of antibiotic prophylaxis on the stability of orthodontic microimplants: A pilot randomized controlled trial10.1016/j.ajodo.2017.11.025 ↗
2. Evaluation of insertion torque and surface integrity of zirconia-coated titanium mini screw implants
3. Efficacy of orthodontic mini implants for en masse retraction in the maxilla: A systematic review and meta-analysis10.1186/s40729-018-0144-4 ↗
4. In vitro study of the orthodontic mini-implants influence on the growth of human osteoblasts10.47162/RJME.62.3.16 ↗
5. An Umbrella Review of the Effectiveness of Temporary Anchorage Devices and the Factors That Contribute to Their Success or Failure10.1016/j.jebdp.2020.101402 ↗
6. Long-term stability behavior of para-median palatal mini-implants: A repeated cross-sectional study10.1016/j.ajodo.2019.01.028 ↗
7. Comparison of Anchorage Efficiency of Orthodontic Mini-implant and Conventional Anchorage Reinforcement in Patients Requiring Maximum Orthodontic Anchorage: A Systematic Review and Meta-analysis10.1016/j.jebdp.2020.101401 ↗
8. Assessment of stiffness and load deflection of orthodontic miniscrews used for palatal anchorage: An in vitro biomechanical study10.1016/j.ortho.2020.08.005 ↗
9. Marchi, A., Camporesi, M., Festa, M., Salvatierra, L., Izadi, S., and Farronato, G. (2020). Drilling Capability of Orthodontic Miniscrews: In Vitro Study. Dent. J., 8.10.3390/dj8040138 ↗
10. Abu Al-Melh, M.M., and Al-Anzi, A.N. (2020). Knowledge of undergraduate dental students toward orthodontic skeletal temporary anchorage devices at Kuwait University. BMC Med. Educ., 20.10.1186/s12909-020-02254-7 ↗
11. Effects of size and insertion angle of orthodontic mini-implants on skeletal anchorage10.1016/j.ajodo.2018.08.026 ↗
12. TAD’s for the Derotation of 90° Rotated Maxillary Bicuspids
13. Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants10.1016/j.ajodo.2011.09.008 ↗
14. Jedliński, M., Janiszewska-Olszowska, J., Mazur, M., Grocholewicz, K., Suárez Suquía, P., and Suárez Quintanilla, D. (2022). How Does Orthodontic Mini-Implant Thread Minidesign Influence the Stability?—Systematic Review with Meta-Analysis. J. Clin. Med., 11.10.3390/jcm11185304 ↗
15. Niroomand, M.R., Arabbeiki, M., and Rouhi, G. (2023). Optimization of thread configuration in dental implants through regulating the mechanical stimuli in neighboring bone. Comput. Methods Programs Biomed., 231.10.1016/j.cmpb.2023.107376 ↗
16. Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness10.1590/2176-9451.19.3.090-094.oar ↗
17. Influence of Geometric Design Characteristics on Primary Stability of Orthodontic Miniscrews10.1007/s00056-018-0131-7 ↗
18. Pitch and longitudinal fluting effects on the primary stability of miniscrew implants10.2319/103108-554R.1 ↗
19. Morphological observations and Fractological considerations on orthodontics miniscrews
20. Titanium alloy orthodontic mini-implants: Scanning electron microscopic and metallographic analyses
21. Popa, A., Dehelean, C., Calniceanu, H., Watz, C., Brad, S., Sinescu, C., Marcu, O.A., Popa, C.S., Avram, S., and Nicolov, M. (2020). Custom-Made Orthodontic Mini-Implant-Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile. Materials, 13.10.3390/ma13214789 ↗
22. Comparison of Stability between Cylindrical and Conical Type Mini-Implants: Mechanical and Histologic Properties10.2319/0003-3219(2008)078[0692:COSBCA]2.0.CO;2 ↗
23. Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque10.4041/kjod.2014.44.4.177 ↗
24. Nica, M., Cretu, B., Ene, D., Antoniac, I., Gheorghita, D., and Ene, R. (2020). Failure Analysis of Retrieved Osteosynthesis Implants. Materials, 13.10.3390/ma13051201 ↗
25. Modification of titanium surface with collagen and doxycycline as a new approach in dental implants10.1080/01694243.2015.1073661 ↗
26. Antoniac, I., Manescu Paltanea, V., Antoniac, A., and Paltanea, G. (2023). Magnesium-based alloys with adapted interfaces for bone implants and tissue engineering. Regen. Biomater., 10.10.1093/rb/rbad095 ↗
27. Rodriguez-Fernandez, J.C., Pastor, F., Barrera Mora, J.M., Brizuela, A., Puigdollers, A., Espinar, E., and Gil, F.J. (2022). Bacteriostatic Poly Ethylene Glycol Plasma Coatings for Orthodontic Titanium Mini-Implants. Materials, 15.10.3390/ma15217487 ↗
28. Ion release and local effects of titanium metal particles from dental implants: An experimental study in rats10.1002/JPER.22-0091 ↗
29. Surface analysis of 2 orthodontic mini-implants after clinical use10.1016/j.ajodo.2015.12.012 ↗
30. Mucins: A biologically relevant glycan barrier in mucosal protection10.1016/j.bbagen.2014.05.003 ↗
31. Long-term durability of orthodontic mini-implants10.1007/s10266-017-0319-0 ↗
32. Gudić, S., Vrsalović, L., Kvrgić, D., and Nagode, A. (2021). Electrochemical Behaviour of Ti and Ti-6Al-4V Alloy in Phosphate Buffered Saline Solution. Materials, 14.10.3390/ma14247495 ↗
33. Jaramillo-Bedoya, D., Villegas-Giraldo, G., Agudelo-Suárez, A.A., and Ramírez-Ossa, D.M. (2022). A Scoping Review about the Characteristics and Success-Failure Rates of Temporary Anchorage Devices in Orthodontics. Dent. J., 10.10.3390/dj10050078 ↗
34. Kazarinov, N., Stotskiy, A., Polyakov, A., Valiev, R.Z., and Enikeev, N. (2022). Finite Element Modeling for Virtual Design to Miniaturize Medical Implants Manufactured of Nanostructured Titanium with Enhanced Mechanical Performance. Materials, 15.10.3390/ma15217417 ↗
35. Systemic levels of metallic ions released from orthodontic mini-implants10.1016/j.ajodo.2007.04.045 ↗
36. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants10.1590/2177-6709.21.5.039-046.oar ↗
37. Biomechanical characteristics and reinsertion guidelines for retrieved orthodontic miniscrews10.2319/092613-703.1 ↗
38. 2015. Surface deterioration and elemental composition of retrieved orthodontic miniscrews10.1016/j.ajodo.2014.10.034 ↗
39. Surface characteristics and mechanical behavior of retrieved orthodontic microimplants10.1631/jzus.B1700324 ↗
40. Effect of different sterilization modes on the surface morphology, ion release, and bone reaction of retrieved micro-implants10.2319/012014-56.1 ↗
41. Evaluation of reused orthodontic mini-implants on stability: An in-vivo study10.1016/j.ajodo.2021.06.024 ↗
42. Surface Properties and Maximum Insertion Energy of Sterilized Orthodontic Mini-Implants with Different Chemical Materials10.37358/RC.18.11.6716 ↗
43. Scanning electron microscope analysis of titanium alloy orthodontic implants10.37358/MP.17.2.4848 ↗
44. Jiman, P.A., Prodan, D., Moldovan, M., Muntean, A., Sarosi, C., Tarmure, V., Baciut, G., Popa, C., and Pop, A.S. (2021). New and Recovered Temporary Anchorage Devices, In Vitro Assessment of Structural and Surface Properties. Materials, 14.10.3390/ma14216271 ↗
45. Stainless steel or titanium mini-implants?10.2319/081619-536.1 ↗
46. Mechanical, Corrosion Resistance Properties and Various Applications of Titanium and Its Alloys: A Review10.18280/rcma.320102 ↗
47. In vivo degradation of orthodontic miniscrew implants: Surface analysis of as-received and retrieved specimens10.1007/s10856-015-5405-7 ↗
48. Evaluation of Serum Metal Ion Levels in Dental Implant Patients: A Prospective Study10.4103/ams.ams_70_21 ↗
49. Microbial Corrosion in Orthodontics10.5005/jp-journals-10024-3290 ↗
50. Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: A systematic review and meta-analysis10.1186/s40510-018-0225-1 ↗
51. Stability of secondarily inserted orthodontic miniscrews after failure of the primary insertion for maxillary anchorage: Maxillary buccal area vs midpalatal suture area10.1016/j.ajodo.2017.05.024 ↗
52. Baseri, M., Radmand, F., Hamedi, R., Yousefi, M., and Kafil, H.S. (2020). Immunological Aspects of Dental Implant Rejection. Biomed Res Int., 2020.10.1155/2020/7279509 ↗
53. Mechanical strength of stainless steel and titanium alloy mini-implants with different diameters: An experimental laboratory study10.1186/s40510-021-00352-w ↗
54. Investigation of Titanium Oxide Layer in Thermal-Electrochemical Anodizing of Ti6Al4V Alloy
55. Corrosion of orthodontic temporary anchorage devices10.1093/ejo/cjs027 ↗
56. Countermeasure for corrosion and hydrogen embrittlement of Ni-Ti superelastic alloy in acidic fluoride solution by adding sodium bicarbonate and hydrogen peroxide10.1080/1478422X.2021.1886740 ↗
57. Gopalakrishnan, U., Thiagarajan, K., Felicita, A.S., Gosh, P., Alshehri, A., Awadh, W., Alzahrani, K.J., Alzahrani, F.M., Alsharif, K.F., and Halawani, I.F. (2022). In-Vitro Assessment of the Corrosion Potential of an Oral Strain of Sulfate-Reducing Bacteria on Metallic Orthodontic Materials. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph192215312 ↗