journal article·2026-05-01Open access

Influence of Reduced Cortical Bone Compression by Implant Macrogeometry on Peri-Implant Bone Healing: An In Vitro and In Vivo Experimental Study

Sergio Alexandre Gehrke, Jaime Aramburú Junior, Tiago Luis Eilers Treichel, Antonio Scarano, Bruno Freitas Mello, Márcio de Carvalho Formiga, Sergio Rexhep Tari, Gustavo Coura, Gustavo Vicentis Oliveira Fernandes

Abstract

Background: Primary stability and long-term osseointegration depend on bone healing surrounding dental implants. Implant macrogeometry is crucial for controlling insertion torque and the biological reaction of peri-implant bone. This study assessed the impact of an implant design meant to lessen cortical bone compression on early bone healing. Methods: Forty titanium prototype implants (3 × 6 mm) were equally divided into Control (standard macrogeometry) and Test (macrogeometry with healing chambers) groups. Initial insertion torque was measured in vitro using synthetic bone blocks. Subsequently, an in vivo rabbit tibia model was used (n = 10 implants per group) to assess early healing. At 21 days, histological sections were analyzed for bone-to-implant contact (BIC%) at three cervical positions (C1, C2, and C3). Additionally, digital radiographs of the cervical region were evaluated using RGB color mapping, where distinct color channels quantified varying degrees of bone density. Results: The in vitro insertion torque for the Control group was significantly greater than the Test group (8.01 vs. 5.70 Ncm). The in vivo histomorphometric analysis indicated improved integration for the Test design, showing substantially higher BIC% at the C2 (59.30% vs. 40.30%) and C3 (42.10% vs. 17.90%) positions. Furthermore, radiographic RGB analysis revealed that the Test group possessed a higher blue channel contribution, indicating greater mineralized tissue density. Conclusions: These results imply that modifying implant macrogeometry to lower insertion torque and minimize cortical bone compression favorably enhances early cervical bone healing and osseointegration.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Cervical and Thoracic Myelopathy · Spine and Intervertebral Disc Pathology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Pharmaceutical Science, School of Health Sciences, Universidade do Vale do Itajai (UNIVALI), Itajai 88302-901, Brazil

Department of Implantology, Bioface/Postgrados en Odontologia/Universidad Catolica de Murcia, Montevideo 11100, Uruguay

Department of Physiology and Pharmacology, Pro-Rectorate of Graduate Studies and Research (PRPGP), Universidade Federal de Santa Maria, Santa Maria 97105-900, Brazil

Department of Surgery, Faculty of Medicine Veterinary, University of Rio Verde, Rio Verde 75901-970, Brazil

Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, 66013 Chieti, Italy

Department of Implantology, Be Dental School, Universidade do Vale do Itajai (UNIVALI), Saint Joseph 88102-700, Brazil

Missouri School of Dentistry and Oral Health, A. T. Still University, St. Louis, MO 63104, USA

GF10 Foundation, St. Louis, MO 63104, USA

Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal

References (49)

Show source-provided references
1. Bone Healing Around Implants in Normal and Medically Compromised Conditions: Oste-oporosis and Diabetes10.1002/adhm.202504701 ↗
2. Manfredini, M., Ghizzoni, M., Cusaro, B., Beretta, M., Maiorana, C., Souza, F.Á., and Poli, P.P. (2025). High Insertion Torque—Clinical Implications and Drawbacks: A Scoping Review. Medicina, 61.10.3390/medicina61071187 ↗
3. The Utility of Evaluating Primary Stability of Implants Using Accumulated Insertion Torque Values: A Preliminary Study10.5037/jomr.2025.16206 ↗
4. Ceddia, M., Montesani, L., Comuzzi, L., Cipollina, A., Deporter, D.A., Di Pietro, N., and Trentadue, B. (2025). The Influence of Insertion Torque on Stress Distribution in Peri-Implant Bones Around Ultra-Short Implants: An FEA Study. Healthcare, 16.10.3390/jfb16070260 ↗
5. Krawiec, K., Kurzawa, A., Słowiński, J.J., Fodor, C.R., and Pałka, Ł. (2025). Experimental Biomechanical Analysis of the Bone-to-Implant Connection in Single-Piece Implants. Materials, 18.10.3390/jfb16100393 ↗
6. Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants10.1016/j.jmbbm.2012.10.010 ↗
7. How does dental implant macro-geometry affect primary implant stability? A narrative review10.1186/s40729-023-00485-z ↗
8. Alemayehu, D.B., Todoh, M., and Huang, S.-J. (2025). Hybrid Biomechanical Design of Dental Implants: Integrating Solid and Gyroid Triply Periodic Minimal Surface Lattice Architectures for Optimized Stress Distribution. J. Funct. Biomater., 16.10.3390/jfb16020054 ↗
9. Major, L., Barrak, I., Braunitzer, G., Piffkó, J., and Antal, M.A. (2026). Effect of Altered Cervical Thread Pitch on the Primary Stability of Dental Implants. J. Clin. Med., 15.10.3390/jcm15020864 ↗
10. Rosas-Díaz, J., Guerrero, M.E., Córdova-Limaylla, N., Galindo-Gómez, M., García-Luna, M., and Cayo-Rojas, C. (2024). The Influence of the Degree of Dental Implant Insertion Compression on Primary Stability Measured by Resonance Frequency and Progressive Insertion Torque: In Vitro Study. Biomedicines, 12.10.3390/biomedicines12122878 ↗
11. Son, K., Son, Y.-T., Hwang, S.-M., Lee, J.M., Kim, J.-W., and Lee, K.-B. (2025). Effects of Two Dental Implant Micromotor Systems for Dental Implant Placement on Implant Stability and Removal Torque: An Animal Experiment. J. Funct. Biomater., 18.10.3390/ma18174048 ↗
12. In vitro evaluation of different implant systems and their influence on primary stability10.1038/s41598-026-35112-5 ↗
13. Gehrke, S.A., Cortellari, G.C., de Oliveira Fernandes, G.V., Scarano, A., Martins, R.G., Cançado, R.M., and Mesquita, A.M.M. (2023). Random-ized clinical trial comparing insertion torque and implant stability of two different implant macrogeometries in the initial periods of osse-ointegration. Medicina, 59.10.3390/medicina59010168 ↗
14. Effects of different implant osteotomy preparation sizes on im-plant stability and bone response in the minipig mandible10.11607/jomi.4165 ↗
15. The effect of osteotomy dimension on implant insertion torque, healing mode, and osseointegration indicators: A study in dogs10.1097/ID.0000000000000476 ↗
16. Ferreira Balan, V., Ferri, M., Pires Godoy, E., Artioli, L.G., Botticelli, D., Silva, E.R., and Xavier, S.P. (2024). Controlled lateral pressure on cortical bone using blade-equipped implants: An experimental study in rabbits. Bioengineering, 11.10.20944/preprints202407.0788.v1 ↗
17. Ferri, M., Guzzo, M., Omori, H., Hazama, Y., Masotta, N.V., and Botticelli, D. (2024). From mechanical machining technology: A new solution that integrates blades to the implant to control the stress to the peri-implant cortical bone. Bioengineering, 11.10.20944/preprints202409.1751.v1 ↗
18. Gehrke, S.A., Cortellari, G.C., Aramburu Junior, J., Treichel, T.L.E., Bianchini, M.A., Scarano, A., and De Aza, P.N. (2024). Preclinical experimental study on new cervical implant design to improve peri-implant tissue healing. Bioengineering, 11.10.20944/preprints202410.1543.v1 ↗
19. Osseodensification versus standard osteotomy: Systematic review and meta-analysis of dental implant torque and stability
20. Repeatability and reproducibility of a new classification for measuring primary stability of dental implants based on progressive insertion torque value: An analytical observational study
21. Araujo, C., Araujo, M.A., Benfatti, C.A.M., Moreira, A.C., Fernandes, C.P., and Michels, R. (2025). Preliminary Assessment of a Hybrid Implant Design Submitted to Immediate Placement with Abutment Exposure: A Pilot Study in One Dog Model. Dent. J., 13.10.3390/dj13100463 ↗
22. Câmara, K., Negretto, A., Pegorini, L.H., Thomé, G., Bernardes, S.R., and Deliberador, T.M. (2025). Retrospective Cohort Study of 4783 Morse Taper Hybrid Dental Implants: Survival Rate Analysis. Bioengineering, 12.10.3390/bioengineering12121305 ↗
23. Analysis of bone stress and primary stability of a dental implant using strain and torque measurements10.1016/j.sdentj.2023.01.006 ↗
24. Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles10.1038/s41598-021-04313-5 ↗
25. Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency analysis: An in vitro study
26. Mohammed, N.B., Daily, Z.A., Ali, M.R., Kazim, N.F., Hussein, H.M., and Mahmood, A.A. (2026). The impact of bite force on the stability of dental implants. PLoS ONE, 26.10.1371/journal.pone.0340355 ↗
27. Perez, A., Bargiela, A.F., and Lombardi, T. (2024). Immediate Implant Placement with Immediate Restorations after Dental Avulsions Due to Endotracheal Intubation in a Patient with Severe Chronic Periodontal Disease. Diagnostics, 14.10.20944/preprints202404.1375.v1 ↗
28. Dura Haddad, C., Andreatti, L., Zelezetsky, I., Porrelli, D., Turco, G., Bevilacqua, L., and Maglione, M. (2024). Primary Stability of Implants Inserted into Polyurethane Blocks: Micro-CT and Analysis In Vitro. Bioengineering, 11.10.3390/bioengineering11040383 ↗
29. Orhan, Z.D., and Ciğerim, L. (2024). Evaluation of Effect of Different Insertion Speeds and Torques on Implant Placement Condition and Removal Torque in Polyurethane Dense D1 Bone Model. Polymers, 16.10.20944/preprints202404.0942.v1 ↗
30. Ioana, T.R., Boeru, F.G., Mitruț, I., Rauten, A.-M., Elsaafin, M., Ionescu, M., Staicu, I.E., and Manolea, H.O. (2025). Analysis of Insertion Torque of Orthodontic Mini-Implants Depending on the System and the Morphological Substrate. J. Funct. Biomater., 16.10.3390/jfb16080291 ↗
31. Ratiu, C.A., Dejeu, D., Croitoru, C.A., Todor, A., Ratiu, I.A., Luca, R.E., Moisa, C., Miclaus, V., and Rus, V. (2025). Early osseous proliferation in spiraled healing chambers resulted after the insertion of titanium implants in cortical bone of a rabbit. Medicina, 62.10.3390/medicina62010072 ↗
32. Al-Awadhi, Z.A., Zhu, S., Ren, J., Geng, N., Mo, S., Luo, C.Y., and Chen, S. (2026). One-year clinical and radiographic outcomes of immediate versus delayed placement of wide-diameter implants in the mandibular molar region. BMC Oral Health, 26.10.1186/s12903-025-07353-9 ↗
33. Velasco-Ortega, E., Ortiz-Garcia, I., Monsalve-Guil, L., López-López, J., Núñez-Márquez, E., Matos-Garrido, N., Rondón-Romero, J.L., Jiménez-Guerra, A., and Moreno-Muñoz, J. (2025). Immediate Loading of Implants Placed Immediately in Fresh Sockets: A 10-Year Single-Arm Prospective Case Series Follow-Up. J. Clin. Med., 14.10.20944/preprints202511.0419.v1 ↗
34. “Compression necrosis”—A cause of concern for early implant failure? Case report and review of literature10.2147/CCIDE.S453798 ↗
35. The Influence of Implant Placement Angulation on Biomechanical Stability In Vitro Study10.4103/jpbs.jpbs_1692_24 ↗
36. Coppedê, A., de Mayo, T., Bassani, R., Rodrigues Olivio, I., de Rossi Figueiredo, D., Romasco, T., Piattelli, A., Di Pietro, N., Mourão, C.F., and de Carvalho Formiga, M. (2025). Effects of High Insertion Torques (≥75 Ncm) on Secondary Stability of Implants Placed According to the "All-on-Four Concept": A 2-Year Clinical Prospective Controlled Case Series Study. Prosthesis, 7.10.3390/prosthesis7010009 ↗
37. (2016). Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments (Standard No. ASTM F1839-08(2016)). Available online: www.astm.org.
38. Conselho Nacional de Controle de Experimentação Animal (CONCEA) (2013). Resolução Normativa n°15, de 16 de dezembro de 2013. Diário Of. União, 245, 9–12.
39. Gehrke, S.A., Aramburu Junior, J., Eilers Treichel, T.L., Colla, G.O., Coura, G., Mello, B.F., de Carvalho Formiga, M., de Campos Buzzi, F., Tari, S.R., and Scarano, A. (2025). Early osseointegration in a sheep tibia model: Correlating digital periapical radiograph gray-level and RGB-derived metrics with histologic tissue composition. J. Funct. Biomater., 16.10.3390/jfb16110415 ↗
40. Stoilov, M., Shafaghi, R., Stoilov, L., Stark, H., Marder, M., Enkling, N., and Kraus, D. (2025). Influence of Drilling Protocol on Primary Implant Stability Depending on Different Bone Qualities and Implant Macro-Designs, Lengths, and Diameters. J. Funct. Biomater., 16.10.3390/jfb16080296 ↗
41. da Silva Brum, I., Elias, C.N., Lopes, J.C.A., Frigo, L., dos Santos, P.G.P., and de Carvalho, J.J. (2024). Clinical Analysis of the Influence of Surface Roughness in the Primary Stability and Osseointegration of Dental Implants: Study in Humans. Coatings, 14.10.20944/preprints202406.0955.v1 ↗
42. Romero-Serrano, M., Romero-Ruiz, M.-M., Herrero-Climent, M., Rios-Carrasco, B., and Gil-Mur, J. (2024). Correlation between Implant Surface Roughness and Implant Stability: A Systematic Review. Dent. J., 12.10.3390/dj12090276 ↗
43. Orhan, Z.D., and Ciğerim, L. (2024). A New Approach to Implant Stability Using a Flexible Synthetic Silicate-Additive Beta-Tricalcium Phosphate-Poly(D,L-lactide-co-caprolactone) Bone Graft: An In Vitro Study. Polymers, 16.10.3390/polym16081101 ↗
44. Quispe-López, N., Martín-Martín, S., Gómez-Polo, C., Figueras-Alvarez, O., Sánchez-Jorge, M.I., and Montero, J. (2024). Primary and Secondary Stability Assessments of Dental Implants According to Their Macro-Design, Length, Width, Location, and Bone Quality. Appl. Sci., 14.10.20944/preprints202405.0773.v1 ↗
45. Are the Insertion Torque Value and Implant Stability Quotient Correlated, and If So, Can Insertion Torque Values Predict Secondary Implant Stability? A Prospective Parallel Cohort Study10.11607/jomi.9064 ↗
46. Evaluation of bone density by cone-beam computed tomography and its relationship with primary stability of dental implants10.4103/1735-3327.340107 ↗
47. Implant insertion torque and marginal bone loss: A systematic review and meta-analysis
48. Clinical effect of the high insertion torque on dental implants: A systematic review and meta-analysis10.1016/j.prosdent.2020.06.012 ↗
49. In-vestigating the effect of insertion torque on marginal bone loss around dental implants10.1016/j.jormas.2023.101523 ↗