journal article·2023-02-19Open access

One-Piece Zirconia Oral Implants for Single Tooth Replacement: Five-Year Results from a Prospective Cohort Study

Ralf-Joachim Kohal, Felix Burkhardt, Jerome Chevalier, Sebastian Berthold Maximilian Patzelt, Frank Butz

Abstract

The intention of this 5-year prospective cohort investigation was to clinically and radiographically investigate the outcomes of a one-piece zirconia implant system for single tooth replacement. Sixty-five patients received a total of 66 single-tooth implants. All implants immediately received temporary restorations and were finally restored with all-ceramic crowns. Follow-ups were performed at the prosthetic delivery, after 1, 3, and 5 years. Peri-implant and dental soft-tissue parameters were evaluated and patient-reported outcomes recorded. To monitor peri-implant bone remodelling, standardised radiographs were taken at the implant insertion and at the 1-, 3-, and 5-year follow-ups. In the course of 5 years, 14 implants were lost, resulting in a cumulative implant survival rate of 78.2%. The mean marginal bone loss from the implant insertion to the 5-year follow-up amounted to 1.12 mm. Probing depth, clinical attachment level, bleeding, and plaque index increased over time. In 91.5% of the implants, the papilla index showed levels of 1 or 2, respectively. At the end of the study, the patient satisfaction was higher compared to the pre-treatment measurements. Due to the low survival rate after five years and the noticeably high frequency of advanced bone loss observed in this study, the implant has not met the launch criteria, as it would have not been recommended for routine clinical use.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany

INSA-Lyon, MATEIS Laboratory, University of Lyon, UMR CNRS 5510, 20 Avenue Albert Einstein, CEDEX, 69621 Villeurbanne, France

Private Dental Clinic, Am Dorfplatz 3, 78658 Zimmern ob Rottweil, Germany

Private Dental Clinic, Belchenstrasse 6a, 79189 Bad Krozingen, Germany

Funding

Nobel Biocare AB, Gothenburg, Sweden

References (52)

Show source-provided references
1. Lorusso, F., Noumbissi, S., Francesco, I., Rapone, B., Khater, A.G.A., and Scarano, A. (2020). Scientific Trends in Clinical Research on Zirconia Dental Implants: A Bibliometric Review. Materials, 13.10.3390/ma13235534 ↗
2. Clinical Longevity of Zirconia Implants with the Focus on Biomechanical and Biological Outcome10.1007/s40496-020-00289-9 ↗
3. Carossa, M., Alovisi, M., Crupi, A., Ambrogio, G., and Pera, F. (2022). Full-Arch Rehabilitation Using Trans-Mucosal Tissue-Level Implants with and without Implant-Abutment Units: A Case Report. Dent. J., 10.10.3390/dj10070116 ↗
4. What Is the Impact of Titanium Particles and Biocorrosion on Implant Survival and Complications? A Critical Review10.1111/clr.13305 ↗
5. Ceramic Steel?10.1038/258703a0 ↗
6. Effect of Zirconia Dental Implant Surfaces on Bone Integration: A Systematic Review and Meta-Analysis10.1155/2017/9246721 ↗
7. Comparison of Clinical Performance of Zirconia Implants and Titanium Implants in Animal Models: A Systematic Review10.11607/jomi.2817 ↗
8. Biomechanical Evaluation of a Microstructured Zirconia Implant by a Removal Torque Comparison with a Standard Ti-SLA Implant10.1111/j.1600-0501.2011.02291.x ↗
9. Bone Response to Functionally Loaded, Two-Piece Zirconia Implants: A Preclinical Histometric Study10.1111/clr.13112 ↗
10. Osteoblast and Bone Tissue Response to Surface Modified Zirconia and Titanium Implant Materials10.1016/j.dental.2013.04.003 ↗
11. Bethke, A., Pieralli, S., Kohal, R.J., Burkhardt, F., von Stein-Lausnitz, M., Vach, K., and Spies, B.C. (2020). Fracture Resistance of Zirconia Oral Implants in Vitro: A Systematic Review and Meta-Analysis. Materials, 13.10.3390/ma13030562 ↗
12. Fracture Resistance and Crystal Phase Transformation of a One- and a Two-piece Zirconia Implant with and without Simultaneous Loading and Aging—An in Vitro Study10.1111/clr.13825 ↗
13. Two-Piece Zirconia Oral Implants Withstand Masticatory Loads: An Investigation in the Artificial Mouth10.1016/j.jmbbm.2015.07.005 ↗
14. de A. Structural and Quantitative Analysis of a Mature Anaerobic Biofilm on Different Implant Abutment Surfaces10.1016/j.prosdent.2015.09.016 ↗
15. Bacterial Colonization of Zirconia Ceramic Surfaces: An in Vitro and in Vivo Study
16. Bacterial Adhesion on Commercially Pure Titanium and Zirconium Oxide Disks: An In Vivo Human Study10.1902/jop.2004.75.2.292 ↗
17. Allergic Contact Dermatitis Caused by Titanium Screws and Dental Implants10.1016/j.jpor.2015.12.004 ↗
18. Is Metal Particle Release Associated with Peri-Implant Bone Destruction? An Emerging Concept10.1177/0022034517740560 ↗
19. Low-Temperature Degradation of Zirconia and Implications for Biomedical Implants10.1146/annurev.matsci.37.052506.084250 ↗
20. Zirconium Dioxide Implants as an Alternative to Titanium: A Systematic Review10.4317/jced.58063 ↗
21. Clinical Performance of Zirconia Implants: A Meta-Review10.1016/j.prosdent.2019.05.017 ↗
22. Bone Tissue Responses to Surface-Modified Zirconia Implants: A Histomorphometric and Removal Torque Study in the Rabbit10.1111/j.1708-8208.2005.tb00070.x ↗
23. Adilstam, F., and Iverhed, M. (2022, December 01). Patent EP1670378A1. Available online: https://patents.google.com/patent/EP1670378A1/en?inventor=Fredrik+Adilstam.
24. Regeneration of Gingival Papillae after Single-Implant Treatment
25. The Microbiota Associated with Successful or Failing Osseointegrated Titanium Implants10.1111/j.1399-302X.1987.tb00298.x ↗
26. Direct Loading of Nobel Direct and Nobel Perfect One-Piece Implants: A 1-Year Prospective Clinical and Radiographic Study10.1111/j.1600-0501.2007.01346.x ↗
27. Altman, D.G. (1999). Practical Statistics for Medical Research, Chapman & Hall/CRC Press. Chapman & Hall/CRC Texts in Statistical Science.
28. Consensus Statements and Recommended Clinical Procedures Regarding Implant Survival and Complications
29. One-Piece Zirconia Oral Implants: One-Year Results from a Prospective Cohort Study. 1. Single Tooth Replacement10.1111/j.1600-051X.2012.01876.x ↗
30. One-Piece Zirconia Oral Implants for Single-Tooth Replacement: Three-Year Results from a Long-Term Prospective Cohort Study10.1111/jcpe.12815 ↗
31. Immediate Occlusal Loading of One-Piece Zirconia Implants: Five-Year Radiographic and Clinical Evaluation10.11607/jomi.3831 ↗
32. Zirconia Implants Restored with Single Crowns or Fixed Dental Prostheses: 5-year Results of a Prospective Cohort Investigation10.1111/clr.13581 ↗
33. Kohal, R.J., Spies, B.C., Vach, K., Balmer, M., and Pieralli, S. (2020). A Prospective Clinical Cohort Investigation on Zirconia Implants: 5-Year Results. J. Clin. Med., 9.10.3390/jcm9082585 ↗
34. Prospective Controlled Clinical Study Investigating Long-term Clinical Parameters, Patient Satisfaction, and Microbial Contamination of Zirconia Implants10.1111/cid.12720 ↗
35. Clinical Outcomes of Zirconia Dental Implants: A Systematic Review10.1177/0022034516664043 ↗
36. Performance and Outcome of Zirconia Dental Implants in Clinical Studies: A Meta-analysis10.1111/clr.13352 ↗
37. Probing Depth at Implants and Teeth. An Experimental Study in the Dog10.1111/j.1600-051X.1993.tb00706.x ↗
38. Bleeding on Probing and Pocket Probing Depth in Relation to Probing Pressure and Mucosal Health around Oral Implants10.1111/j.1600-0501.2008.01601.x ↗
39. Histologic Probe Penetration in Healthy and Inflamed Peri-Implant Tissues: Probing around Implants10.1034/j.1600-0501.1994.050401.x ↗
40. Periodontal Tissues and Their Counterparts around Endosseous Implants: Periodontal versus “Peri-Implant” Tissues10.1034/j.1600-0501.1991.020101.x ↗
41. Peri-Implant Bone Response to Retrieved Human Zirconia Oral Implants after a 4-Year Loading Period: A Histologic and Histomorphometric Evaluation of 22 Cases: Peri-Implant Bone Response To Retrieved Human Zirconia Oral Implants10.1002/jbm.b.33512 ↗
42. Clinical Evaluation of a Prospective Multicenter Study on 1-Piece Implants. Part 1: Marginal Bone Level Evaluation after 1 Year of Follow-Up
43. Clinical Performance and Radiographic Evaluation of a Novel Single-Piece Implant in a Private Practice over a Mean of Seventeen Months10.1016/S0022-3913(07)60010-9 ↗
44. Survival of NobelDirect Implants: An Analysis of 550 Consecutively Placed Implants at 18 Different Clinical Centers10.1111/j.1708-8208.2007.00054.x ↗
45. Scalloped Dental Implants: A Retrospective Analysis of Radiographic and Clinical Outcomes of 17 NobelPerfectTM Implants in 6 Patients: Scalloped Dental Implants10.2310/j.6480.2005.00034.x ↗
46. Short-Term Clinical Results of Nobel Direct Implants: A Retrospective Multicentre Analysis10.1111/j.1600-0501.2007.01410.x ↗
47. Two-Year Outcome with Nobel Direct® Implants: A Retrospective Radiographic and Microbiologic Study in 10 Patients10.1111/j.1708-8208.2008.00112.x ↗
48. Immediately Restored One-Piece Single-Tooth Implants with Reduced Diameter: One-Year Results of a Multi-Center Study: Immediately Restored One-Piece Implants10.1111/j.1600-0501.2011.02174.x ↗
49. In Vivo Study of the Initial Bacterial Adhesion on Different Implant Materials10.1016/j.archoralbio.2013.04.011 ↗
50. Peri-Implantitis10.1111/jcpe.12954 ↗
51. Sanon, C. (2014). Lumière Sur La Zircone 3Y-TZP Utilisée En Implantologie Orale: Etude de La Relation Entre La Microstructure et La Durabilité, INS-Lyon.
52. Dissemination and Publication of Research Findings: An Updated Review of Related Biases10.3310/hta14080 ↗