journal article·2026-01-24Open access

Medial Malleolar Fracture Fixation with Stainless Steel, Titanium, Magnesium, and PLGA Screws: A Finite Element Analysis

Mehmet Melih Asoglu, Volkan Kızılkaya, Ali Levent, Huseyin Kursat Celik, Ozkan Kose, Allan E. W. Rennie

Abstract

Background: Implant material may influence interfragmentary mechanics in medial malleolar (MM) fracture fixation. This study aimed to compare stainless steel, titanium, magnesium, and PLGA screws under identical conditions using finite element analysis (FEA). Methods: A CT-based ankle model with a unilateral oblique MM fracture (θ = 60° to the medial tibial plafond) was fixed with two parallel M4 × 35 mm screws placed perpendicular to the fracture plane (inter-axial distance 13 mm). Contacts were defined as nonlinear frictional, and each screw was assigned a pretension force of 2.5 N. Static single-leg stance was simulated with physiologic tibia/fibula load sharing. Four scenarios differed only by screw material. Primary outputs were interfragmentary micromotion (maximum sliding and gap). Secondary measures included fracture interface contact/frictional stresses, screw/bone von Mises stress, global construct displacement, and average tibiotalar cartilage contact pressure. Results: Interfragmentary micromotion increased as screw stiffness decreased. Maximum sliding was 32.2–33.8 µm with stainless steel/titanium, 40.4 µm with magnesium, and 65.0 µm with PLGA; corresponding gaps were 31.2–32.0 µm with stainless steel and titanium, 31.2 µm with magnesium, and 54.1 µm with PLGA, respectively. Interface stresses followed the same pattern: contact pressure (3.18–3.24 MPa for stainless steel/titanium/magnesium vs. 4.29 MPa for PLGA); frictional stress (1.46–1.49 MPa vs. 1.98 MPa). Peak screw von Mises stress was highest in stainless steel (104.1 MPa), then titanium (73.4 MPa), magnesium (47.4 MPa), and PLGA (17.9 MPa). Global axial displacement (0.26–0.27 mm) and average tibiotalar cartilage contact pressure (0.73–0.75 MPa) were essentially unchanged across materials. All conditions remained below commonly cited thresholds for primary bone healing (gap < 100 µm); however, PLGA exhibited a reduced safety margin. Conclusions: Under identical geometry and loading conditions, titanium and stainless steel yielded the most favorable interfragmentary mechanics for oblique MM fixation; magnesium showed intermediate performane, and PLGA produced substantially greater micromotion and interface stresses. These findings support the use of metallic screws when maximal initial stability is required and suggest that magnesium may be a selective alternative when reducing secondary implant removal is prioritized.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Foot and Ankle Surgery · Bone fractures and treatments · Knee injuries and reconstruction techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Orthopedics and Traumatology Clinic, Private Metrolife Hospital, Sanliurfa 63320, Turkey

Department of Agricultural Machinery and Technology Engineering, Akdeniz University, Antalya 07070, Turkey

Engineering Department, Lancaster University, Lancaster LA1 4YW, UK

Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, Antalya 07100, Turkey

References (62)

Show source-provided references
1. Bergh, C., Wennergren, D., Möller, M., and Brisby, H. (2020). Fracture incidence in adults in relation to age and gender: A study of 27,169 fractures in the Swedish Fracture Register in a well-defined catchment area. PLoS ONE, 15.10.1371/journal.pone.0244291 ↗
2. Population-based epidemiology of 9767 ankle fractures10.1016/j.fas.2016.11.002 ↗
3. Incidence, treatment, and mortality of ankle fractures: A Danish population-based cohort study10.2340/17453674.2025.43006 ↗
4. Conservative treatment of isolated fractures of the medial malleolus10.1302/0301-620X.89B1.18349 ↗
5. Current Concepts in Ankle Fracture Management10.1016/j.cpm.2024.01.008 ↗
6. The functional outcome and quality of life after treatment of isolated medial malleolar fractures10.1016/j.fas.2016.06.004 ↗
7. Contribution of the medial malleolus to tibiotalar joint contact characteristics10.1177/1938640014546862 ↗
8. The effect of early weight-bearing and later weight-bearing rehabilitation interventions on outcomes after ankle fracture surgery: A systematic review and meta-analysis of randomised controlled trials10.1002/jfa2.12011 ↗
9. Comparison of surgical techniques of 111 medial malleolar fractures classified by fracture geometry10.1177/1071100714524553 ↗
10. Tension band wiring versus screw fixation for the treatment of medial malleolar fractures: A systematic review and meta-analysis10.1016/j.otsr.2022.103447 ↗
11. Effect of buttress plate in Herscovici type D vertical medial malleolar fractures and peripheral fractures: A retrospective comparative cohort study10.1186/s13018-023-03889-0 ↗
12. Complications of implant removal in ankle fractures10.1016/j.jor.2019.02.017 ↗
13. Routine implant removal after fracture surgery: A potentially reducible consumer of hospital resources in trauma units10.1097/00005373-199611000-00013 ↗
14. Incidence of hardware-related pain and its effect on functional outcomes after open reduction and internal fixation of ankle fractures10.1097/00005131-200105000-00006 ↗
15. Complications After Ankle Fracture Surgery in Finland Between 1998 and 202010.2106/JBJS.23.00745 ↗
16. Bioabsorbable implants are a viable alternative to traditional metallic implants in orthopaedic surgery: A systematic review and meta-analysis10.1016/j.jor.2025.06.005 ↗
17. Alterations in magnetic resonance imaging characteristics of bioabsorbable magnesium screws over time in humans: A retrospective single center study
18. Bioabsorbable magnesium screw versus conventional titanium screw fixation for medial malleolar fractures10.1186/s10195-020-00547-7 ↗
19. Comparison of Bioabsorbable Magnesium versus Titanium Screw Fixation for Modified Distal Chevron Osteotomy in Hallux Valgus10.1155/2018/5242806 ↗
20. Fixation of medial malleolar fractures with magnesium bioabsorbable headless compression screws: Short-term clinical and radiological outcomes in eleven patients10.1007/s00402-018-2941-x ↗
21. Bioabsorbable screw fixation for the treatment of ankle fractures10.1007/s00776-006-1077-y ↗
22. Two-screw osteosynthesis of the mandibular condylar head with different screw materials: A finite element analysis10.1080/10255842.2023.2209247 ↗
23. Biomechanical evaluation of magnesium-based resorbable metallic screw system in a bilateral sagittal split ramus osteotomy model using three-dimensional finite element analysis10.1016/j.joms.2013.10.003 ↗
24. Comparison of Titanium, Magnesium, and Polymer-based Cortical Screw Fixation for Fulkerson Tibial Tubercle Osteotomy: A Finite Element Analysis
25. Application of biodegradable implants in pediatric orthopedics: Shifting from absorbable polymers to biodegradable metals
26. 3-D computer modelling of malunited posterior malleolar fractures: Effect of fragment size and offset on ankle stability, contact pressure and pattern10.1186/s13047-017-0194-5 ↗
27. Physical validation of a patient-specific contact finite element model of the ankle10.1016/j.jbiomech.2007.01.024 ↗
28. Zhu, Z.J., Zhu, Y., Liu, J.F., Wang, Y.P., Chen, G., and Xu, X.Y. (2016). Posterolateral ankle ligament injuries affect ankle stability: A finite element study. BMC Musculoskelet. Disord., 17.10.1186/s12891-016-0954-6 ↗
29. Orientation dependence of progressive post-yield behavior of human cortical bone in compression10.1016/j.jbiomech.2012.08.034 ↗
30. Wang, X., Nyman, J.S., Dong, X., Leng, H., and Reyes, M. (2010). Fundamental Biomechanics in Bone Tissue Engineering, Springer Nature. Synthesis Lectures on Tissue Engineering.10.1007/978-3-031-02579-2 ↗
31. The finite element analysis of a fractured tibia applied by composite bone plates considering contact conditions and time-varying properties of curing tissues10.1016/j.compstruct.2009.09.051 ↗
32. Finite element analysis of large deformation of articular cartilage in the upper ankle joint of occupants in military vehicles during explosion10.1515/amm-2015-0356 ↗
33. Creep of trabecular bone from the human proximal tibia10.1016/j.msec.2014.03.057 ↗
34. Strength pattern of cancellous bone at the ankle joint10.1243/EMED_JOUR_1988_017_020_02 ↗
35. Lu, Y., Cheng, D., Niu, B., Wang, X., Wu, X., and Wang, A. (2023). Properties of Poly (Lactic-co-Glycolic Acid) and Progress of Poly (Lactic-co-Glycolic Acid)-Based Biodegradable Materials in Biomedical Research. Pharmaceuticals, 16.10.3390/ph16030454 ↗
36. ANSYS, Inc. (2025, May 01). ANSYS Granta Selector (Version 2025.R1) [Computer Software]. ANSYS, Inc.. Available online: https://www.ansys.com.
37. A comparison of friction measurements of intact articular cartilage in contact with cartilage, glass, and metal
38. Biomechanical behaviours of the bone-implant interface: A review10.1098/rsif.2019.0259 ↗
39. Plate-bone friction in the compression fixation of fractures10.1097/00003086-197211000-00030 ↗
40. A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests10.1243/09544119JEIM799 ↗
41. Fixation of distal fibular fractures: A biomechanical study of plate fixation techniques
42. Fibula and its ligaments in load transmission and ankle joint stability10.1097/00003086-199609000-00034 ↗
43. ANSYS Product Doc. (2019). ANSYS Meshing User’s Guide: Skewness (Release 2019 R2), ANSYS Inc.
44. A Robust Measure of Skewness10.1198/106186004X12632 ↗
45. Cortical bone repair: The relationship of the lacunar-canalicular system and intercellular gap junctions to the repair process10.2106/00004623-198870070-00016 ↗
46. How plate positioning impacts the biomechanics of the open wedge tibial osteotomy; a finite element analysis10.1080/10255840500322433 ↗
47. The initial safe range of motion of the ankle joint after three methods of internal fixation of simulated fractures of the medial malleolus10.1016/j.clinbiomech.2005.12.018 ↗
48. Mechanical and numerical investigations of biodegradable magnesium alloy screws for fracture treatment10.1002/jbm.b.35127 ↗
49. Park, B., Jung, B.T., Kim, W.H., Lee, J.H., Kim, B., and Lee, J.H. (2020). The Stability of Hydroxyapatite/Poly-L-Lactide Fixation for Unilateral Angle Fracture of the Mandible Assessed Using a Finite Element Analysis Model. Materials, 13.10.3390/ma13010228 ↗
50. Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: A finite element analysis10.1186/s13018-021-02665-2 ↗
51. A lean bioabsorbable magnesium-zinc-calcium alloy ZX00 used for operative treatment of medial malleolus fractures: Early clinical results of a prospective non-randomized first in man study10.1302/2046-3758.98.BJR-2020-0017.R2 ↗
52. Mg-Zn-Ca Alloy (ZX00) Screws Are Resorbed at a Mean of 2.5 Years After Medial Malleolar Fracture Fixation: Follow-up of a First-in-humans Application and Insights From a Sheep Model10.1097/CORR.0000000000002799 ↗
53. Nudelman, H., Lőrincz, A., Lamberti, A.G., Varga, M., Kassai, T., and Józsa, G. (2024). Management of Juvenile Osteochondral Fractures Utilising Absorbable PLGA Implants. J. Clin. Med., 13.10.3390/jcm13020375 ↗
54. Polyglycolide bioabsorbable screws in the treatment of ankle fractures10.1177/107110079701800303 ↗
55. Nudelman, H., Lőrincz, A., Lamberti, A.G., Varga, M., Kassai, T., and Józsa, G. (2024). Management of pediatric ankle fractures: Comparison of biodegradable PLGA implants with traditional metal screws. Front. Pediatr., 12.10.3389/fped.2024.1410750 ↗
56. Fixation with bioabsorbable screws for the treatment of fractures of the ankle10.2106/00004623-199403000-00001 ↗
57. Fracture healing: Fracture healing understood as the result of a fascinating cascade of physical and biological interactions. Part II10.55095/achot2015/002 ↗
58. Fracture healing: Fracture healing understood as the result of a fascinating cascade of physical and biological interactions. Part I. An Attempt to Integrate Observations from 30 Years AO Research10.55095/achot2014/049 ↗
59. A clinical evaluation of alternative fixation techniques for medial malleolus fractures10.1016/j.injury.2014.05.031 ↗
60. Medial malleolar fractures: Current treatment concepts10.1302/0301-620x.101B5.BJJ-2019-0070 ↗
61. Nudelman, H., Molnár, T., and Józsa, G. (2026). Biodegradable (PLGA) Implants in Pediatric Trauma: A Brief Review. Children, 13.10.20944/preprints202511.0107.v1 ↗
62. Wi, J., Choi, J., and Lee, S.H. (2025). PLA-Based Biodegradable Polymer from Synthesis to the Application. Polymers, 18.10.3390/polym18010121 ↗