journal article·2024-12-21Open access

Micro-CT Assessment During Embedding of Prototype Ti Alloy Multi-Spiked Connecting Scaffold in Subchondral Trabecular Bone of Osteoarthritic Femoral Heads, Depending on Host BMI

Ryszard Uklejewski, Mariusz Winiecki, Adam Patalas, Patryk Mietliński, Paweł Zawadzki, Mikołaj Dąbrowski

Journal of Functional Biomaterials· Volume 15· Issue 12

Abstract

The prototype of a biomimetic multi-spiked connecting scaffold (MSC-Scaffold) represents an essential innovation in the fixation in subchondral trabecular bone of components for a new generation of entirely cementless hip resurfacing arthroplasty (RA) endoprostheses. In designing such a functional biomaterial scaffold, identifying the microstructural and mechanical properties of the host bone compromised by degenerative disease is crucial for proper post-operative functioning and long-term maintenance of the endoprosthesis components. This study aimed to explore, depending on the occurrence of obesity, changes in the microstructure and mechanical properties of the subchondral trabecular bone in femoral heads of osteoarthritis (OA) patients caused by the MSC-Scaffold embedding. Computed microtomography (micro-CT) scanning of femoral heads from OA patients was conducted before and after the mechanical embedding of the MSC-Scaffold. Bone morphometric parameters such as bone volume/total volume (BV/TV), trabecular thickness (Tb.Th), and trabecular number (Tb.N) for regions surrounding the MSC-Scaffold were computed, and the mechanical properties such as bone density (ρB), bone compressive strength (S), and the Young’s modulus (E) within these regions were calculated. A statistically significant increase in BV/TV (by 15.0% and 24.9%) and Tb.Th (by 13.1% and 42.5%) and a decrease in Tb.N (by 15.2% and 23.6%) were observed, which translates to an increase in ρB (by 15.0% and 24.9%), S (by 28.8% and 49.5%), and E (by 18.0% and 29.8%) in non-obese patients and obese patients, respectively. These changes in properties are favorable for the mechanical loads’ transfer from the artificial joint surface via the MSC-Scaffold to the periarticular trabecular bone of the OA femoral head in the postoperative period.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Hip disorders and treatments · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Constructional Materials and Biomaterials, Faculty of Materials Engineering, Kazimierz Wielki University, Jan Karol Chodkiewicz Street 30, 85-064 Bydgoszcz, Poland

Institute of Mechanical Technology, Poznan University of Technology, Piotrowo 3, 60-965 Poznan, Poland

Adult Spine Orthopaedics Department, W. Dega Orthopaedic and Rehabilitation Clinical Hospital, Poznan University of Medical Sciences, 28 Czerwca 1956 Street 135/147, 61-545 Poznan, Poland

References (35)

Show source-provided references
1. Rogala, P., Uklejewski, R., Winiecki, M., Dąbrowski, M., Gołańczyk, J., and Patalas, A. (2019). First Biomimetic Fixation for Resurfacing Arthroplasty: Investigation in Swine of a Prototype Partial Knee Endoprosthesis. BioMed Res. Int., 2019.10.1155/2019/6952649 ↗
2. Uklejewski, R., Rogala, P., and Winiecki, M. (2024). Prototype of a Biomimetic Multi-Spiked Connecting Scaffold for a New Generation of Resurfacing Endoprostheses, CRC Press/Taylor & Francis Group. [1st ed.].10.1201/9781003364498 ↗
3. The basic science of the subchondral bone10.1007/s00167-010-1054-z ↗
4. Uklejewski, R., Winiecki, M., Patalas, A., and Rogala, P. (2021). Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses. Materials, 14.10.3390/ma14061384 ↗
5. My current indications for hip resurfacing10.21037/aoj.2019.12.05 ↗
6. Patient-specific resurfacing implant knee surgery in subjects with early osteoarthritis results in medial pivot and lateral femoral rollback during flexion: A retrospective pilot study10.1007/s00167-021-06749-8 ↗
7. Hip resurfacing versus total hip arthroplasty: A systematic review and meta-analysis of randomized clinical trials10.1007/s00264-024-06269-3 ↗
8. Cost-Effectiveness Analyses of Total Hip Arthroplasty for Hip Osteoarthritis: A PRISMA Systematic Review10.1111/ijcp.13806 ↗
9. A public health approach to osteoarthritis in the United States10.1016/j.joca.2023.12.004 ↗
10. The burden of OA-health services and economics10.1016/j.joca.2021.05.007 ↗
11. 8136 Using High-Resolution Peripheral Quantitative Computed Tomography to Assess Bone Microarchitecture and Guide Osteoporosis Treatment10.1210/jendso/bvae163.532 ↗
12. Micro-CT assessments of potential anti-osteoporotic agents10.2174/13894501113149990196 ↗
13. Novel approaches to correlate computerized tomography imaging of bone fracture callus to callus structural mechanics10.1016/j.bonr.2023.101726 ↗
14. Orhan, K. (2020). Application of Bone Morphometry and Densitometry by X-Ray Micro-CT to Bone Disease Models and Phenotypes. Micro-Computed Tomography (Micro-CT) in Medicine and Engineering, Springer.10.1007/978-3-030-16641-0 ↗
15. Dąbrowski, M., Rogala, P., Uklejewski, R., Patalas, A., Winiecki, M., and Gapiński, B. (2021). Subchondral Bone Relative Area and Density in Human Osteoarthritic Femoral Heads Assessed with Micro-CT before and after Mechanical Embedding of the Innovative Multi-Spiked Connecting Scaffold for Resurfacing THA Endoprostheses: A Pilot Study. J. Clin. Med., 10.10.3390/jcm10132937 ↗
16. Uklejewski, R., Winiecki, M., Rogala, P., and Patalas, A. (2017). Structural-Geometric Functionalization of the Additively Manufactured Prototype of Biomimetic Multi-spiked Connecting Ti-Alloy Scaffold for Entirely Noncemented Resurfacing Arthroplasty Endoprostheses. Appl. Bionics Biomech., 2017.10.1155/2017/5638680 ↗
17. The effect of different storage methods on the mechanical properties of trabecular bone10.1016/0021-9290(93)90072-M ↗
18. Influence of three different preservative techniques on the mechanical properties of the ovine cortical bone
19. An, Y.H., and Draughn, R.A. (1999). Mechanical Testing of Bone and the Bone-Implant Interface, CRC Press. [1st ed.].10.1201/9781420073560 ↗
20. An, Y.H., and Martin, K.L. (2003). Handbook of Histology Methods for Bone and Cartilage, Humana Press.10.1385/1592594174 ↗
21. Reconstruction and Modeling of Porous Transport Layers Based on X-ray Computed Tomography Imaging10.1021/acsaem.4c02193 ↗
22. Micro-computed tomography pore-scale study of flow in porous media: Effect of voxel resolution10.1016/j.advwatres.2015.07.012 ↗
23. Orientation of orthotropic material properties in a femur FE model: A method based on the principal stresses directions10.1016/j.medengphy.2011.10.008 ↗
24. Image Thresholding by Minimizing the Measures of Fuzziness10.1016/0031-3203(94)E0043-K ↗
25. Comparative Study on Threshold Selection for Measuring Characteristics of Turbulent Swirling Flames in a Miniature-Scale Swirl Burner10.1007/s11760-022-02344-7 ↗
26. Decision Thresholding on fMRI Activation Maps Using the Hilbert–Huang Transform10.1088/1741-2552/ac7f5e ↗
27. A Novel Measurement for Monitoring Mechanical Impedance Applied to Breakthrough Detection of Bone-Drill System10.1088/1757-899X/398/1/012028 ↗
28. Optimization of digital volume correlation computation in SR-microCT images of trabecular bone and bone-biomaterial systems10.1111/jmi.12745 ↗
29. Adams, G.J., Cook, R.B., Hutchinson, J.R., and Zioupos, P. (2018). Bone Apparent and Material Densities Examined by Cone Beam Computed Tomography and the Archimedes Technique: Comparison of the Two Methods and Their Results. Front. Mech. Eng., 3.10.3389/fmech.2017.00023 ↗
30. Some basic relationships between density values in cancellous and cortical bone10.1016/j.jbiomech.2008.03.025 ↗
31. Comparison of Bone Density Measurement Techniques: DXA and Archimedes’ Principle10.1359/jbmr.1997.12.11.1903 ↗
32. Mechanical properties of trabecular bone from the proximal femur: A quantitative CT study10.1097/00004728-199001000-00020 ↗
33. Fleps, I., Bahaloo, H., Zysset, P.K., Ferguson, S.J., Pálsson, H., and Helgason, B. (2020). Empirical relationships between bone density and ultimate strength: A literature review. J. Mech. Behav. Biomed. Mater., 110.10.1016/j.jmbbm.2020.103866 ↗
34. Variations in three-dimensional cancellous bone architecture of the proximal femur in female hip fractures and in controls10.1359/jbmr.2000.15.1.32 ↗
35. Mathematical relationships between bone density and mechanical properties: A literature review10.1016/j.clinbiomech.2007.08.024 ↗