Abstract

Abstract Biocompatibility tests and a study of the electrical properties of thin films prepared from six electroactive polymer ink formulations based on poly(3,4‐ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) were performed. The aim was to find a suitable formulation of PEDOT:PSS and conditions for preparing thin films in order to construct printed bioelectronic devices for biomedical applications. The stability and electrical properties of such films were tested on organic electrochemical transistor (OECT)‐based sensor platforms and their biocompatibility was evaluated in assays with 3T3 fibroblasts and murine cardiomyocytes. It was found that the thin films prepared from inks without an additive or any thin film post‐treatment provide limited conductivity and stability for use in biomedical applications. These properties were greatly improved by using ethylene glycol and thermal annealing. Addition or post‐treatment by ethylene glycol in combination with thermal annealing provided thin films with electrical resistance and a stability sufficient to be used in sensing of animal cell physiology. These films coated with collagen IV showed good biocompatibility in the assay with 3T3 fibroblasts when compared to standard cell culture plastics. Selected films were then used in assays with murine cardiomyocytes. We observed that these cells were able to attach to the PEDOT:PSS films and form an active sensor element. Spontaneously beating clusters were formed, indicating a good physiological status for the cardiomyocyte cells. These results open the door to construction of cheap printed electronic devices for biointerfacing in biomedical applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1121–1128, 2018.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Conducting polymers and applications · Advanced Sensor and Energy Harvesting Materials · Neuroscience and Neural Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Materials Research Centre, Faculty of Chemistry Brno University of Technology, Purkyňova 118 Brno 612 00 Czech Republic

Institute of Biophysics of the Czech Academy of Sciences, Královopolská 135 Brno 612 65 Czech Republic

International Clinical Research Center‐Center of Biomolecular and Cell Engineering St. Anne's University Hospital Brno, Pekařská 53 Brno 656 91 Czech Republic

Department of Experimental Biology, Faculty of Science Masaryk University, University Campus Bohunice, Kamenice 5 Brno 625 00 Czech Republic

Centrum Organické Chemie, Rybitví 296 Rybitví 533 54 Czech Republic

Funding

Grantová Agentura České Republiky · Ministerstvo Školství, Mládeže a Tělovýchovy

References (31)

Show source-provided references
1. 10.1007/s10854-015-2895-510.1007/s10854-015-2895-5 ↗
2. 10.1117/1.JPE.5.05761110.1117/1.JPE.5.057611 ↗
3. 10.1002/aelm.20150001710.1002/aelm.201500017 ↗
4. 10.1016/j.msec.2013.01.03510.1016/j.msec.2013.01.035 ↗
5. Bernard C · 2016 · 34510.1142/9789813148611_0011 ↗
6. 10.1002/adma.20090018710.1002/adma.200900187 ↗
7. 10.1002/jbm.a.3486910.1002/jbm.a.34869 ↗
8. 10.1002/polb.2319210.1002/polb.23192 ↗
9. 10.1109/JSEN.2014.237520310.1109/JSEN.2014.2375203 ↗
10. Organic electrochemical transistors microplate for real‐time cell culture monitoring10.3390/app7100998 ↗
11. Cytotoxicity of biomaterials—Basic mechanisms and in vitro test methods: A review10.1177/026119299502300609 ↗
12. 10.1002/jps.260054013910.1002/jps.2600540139 ↗
13. 10.1002/(SICI)1097-4636(19980905)41:3<422::AID-JBM12>3.0.CO;2-K10.1002/(SICI)1097-4636(19980905)41:3<422::AID-JBM12>3.0.CO;2-K ↗
14. 10.1089/ten.2005.11.110.1089/ten.2005.11.1 ↗
15. JonasF KrafftW.European Patent EP 440 957 (Bayer AG) 1990.
16. Towards highly biocompatible organic semiconductors interfaces for bioelectronic devices
17. Simple non‐invasive analysis of embryonic stem cell‐derived cardiomyocytes beating in vitro10.1063/1.4941776 ↗
18. 10.1002/adfm.20060123910.1002/adfm.200601239 ↗
19. Elschner A · 2011
20. 10.1002/adma.20130308010.1002/adma.201303080 ↗
21. 10.1002/adma.20140170610.1002/adma.201401706 ↗
22. 10.1083/jcb.17.2.29910.1083/jcb.17.2.299 ↗
23. 10.1073/pnas.141228511110.1073/pnas.1412285111 ↗
24. 10.1021/ma900137k10.1021/ma900137k ↗
25. 10.1016/j.actbio.2014.02.01510.1016/j.actbio.2014.02.015 ↗
26. 10.1016/j.electacta.2012.03.09710.1016/j.electacta.2012.03.097 ↗
27. 10.1002/app.4173510.1002/app.41735 ↗
28. 10.1021/nl402901y10.1021/nl402901y ↗
29. 10.1016/j.scr.2009.11.00410.1016/j.scr.2009.11.004 ↗
30. 10.1177/221106821456283210.1177/2211068214562832 ↗
31. 10.1002/adhm.20140040610.1002/adhm.201400406 ↗