In vitro evaluation of atmospheric plasma treatment for enhancing the biological response of a laser textured titanium dental implant surface
Source abstract
Abstract
A standard titanium grit-blasted acid-etched (GBAE) surface, a patterned titanium laser surface (LS) and the same LS treated with atmospheric plasma (Plasma-LS) were characterized morphologically and chemically through Scanning Electron Microscope/Energy Dispersive X-ray analysis. According to the X-ray Photoelectron Spectroscopy C, O, and N were the most abundant contaminants on the three titania surfaces. Based on multi-parametric surface measurements, including the developed interfacial area ratio (Sdr), LS (Sdr = 105.00 +/- 3.00%) and Plasma-LS (Sdr = 50.00 +/- 3.00%) exhibited significantly higher values compared to GBAE (Sdr = 3.05 +/- 0.11%). As for the optical contact angle measurements, Plasma-LS did not show detectable angles, while LS presented greater affinity to both water and diiodomethane compared to GBAE. Plasma-LS displayed the highest total surface energy (73mJ/m2), almost equally distributing the polar (gamma P) and dispersive (gamma D) components, while gamma P/gamma D ratio was close to 1/3 in GBAE and LS. Plasma-LS adsorbed significantly the highest amount of bovine serum albumin. At 24 h, on GBAE, cells spread more and were more circular than on LS and Plasma-LS. Based on the viability assay, Plasma-LS, outperformed significantly GBAE and LS, after 3 and 7 days of culture. Further studies and clinical trials are required to establish the efficacy and safety of this acid-free surface modification for osseointegration.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Laser Applications in Dentistry and Medicine · Periodontal Regeneration and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Basic concepts and techniques of dental implants10.1016/j.cden.2014.10.005 ↗
2. A critical review of dental implant materials with an emphasis on titanium versus zirconia10.3390/ma8030932 ↗
3. Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man10.3109/17453678108991776 ↗
4. The influence of thread geometry on implant osseointegration under immediate loading: a literature review10.4047/jap.2014.6.6.547 ↗
5. Biomaterials for dental implants: current and future trends10.1007/s10853-015-9056-3 ↗
6. Surface modification techniques of titanium and titanium alloys for biomedical dental applications: a review10.1016/j.matpr.2020.06.163 ↗
7. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
8. Comparison of osseointegration in novel laser-textured and SLA implants10.5455/aim.2023.31.137-140 ↗
9. Osteoblast response to widely ranged texturing conditions obtained through high power laser beams on Ti surfaces
10. Implant surface characteristics and their effect on osseointegration10.1038/sj.bdj.2015.171 ↗
11. Recent advances of additive manufacturing in implant fabrication – a review10.1016/j.apsadv.2023.100462 ↗
12. UV-A and UV-C light induced hydrophilization of dental implants10.1016/j.dental.2015.04.011 ↗
13. Ultraviolet photofunctionalization of titanium implants10.11607/jomi.te47 ↗
14. The emerging role of cold atmospheric plasma in implantology: a review of the literature10.3390/nano10081505 ↗
15. Plasma of argon affects the earliest biological response of different implant surfaces: an in vitro comparative study10.1177/0022034516629119 ↗
16. Influence of cold atmospheric plasma on dental implant materials — an in vitro analysis10.1007/s00784-021-04277-w ↗
17. Blateyron · 2024
18. Tip–sample characterization in the AFM study of a rod-shaped nanostructure10.1088/1361-6501/ab7bc2 ↗
19. Resistance of solid surfaces to wetting by water10.1021/ie50320a024 ↗
20. Early biological response to poly(ε-caprolactone)/alumina-toughened zirconia composites obtained by 3D printing for peri-implant application10.3390/polym16172521 ↗
21. Surface energy and wettability of van der waals structures10.1039/C5NR06705G ↗
22. M. Pachitariu, M. Rariden, S.C. Cellpose-SAM, Superhuman Generalization for Cellular Segmentation, 2025.10.1101/2025.04.28.651001 ↗
23. Early biological response to poly(ε-caprolactone) PCL—bioactive glass composites obtained by 3D printing as bone substitutes10.3390/polym17162229 ↗
24. Differential responses of osteoblast lineage cells to nanotopographically-modified, microroughened titanium–aluminum–vanadium alloy surfaces10.1016/j.biomaterials.2012.08.059 ↗
25. Modulating the biological response in vitro through hydrofluoric acid surface etching of ceria-stabilized zirconia/alumina/strontium hexa-aluminate composites10.1016/j.colsurfb.2025.115195 ↗
26. Beta1-integrin and TRPV4 are involved in osteoblast adhesion to different titanium surface topographies10.1016/j.apsusc.2019.145112 ↗
27. Oral implant surfaces: Part 1–review focusing on topographic and chemical properties of different surfaces and in vivo responses to them
28. Plasma of argon increases cell attachment and bacterial decontamination on different implant surfaces10.11607/jomi.5777 ↗
29. I.A. Hashim, Plasma and Body Fluids Proteins. In Tutorials in Clinical Chemistry; Elsevier, 2024; pp. 271–295 ISBN 978-0-12-822949-1.10.1016/B978-0-12-822949-1.00012-7 ↗
30. Micro/nanostructured calcium phytate coating on titanium fabricated by chemical conversion deposition for biomedical application10.1016/j.msec.2020.111402 ↗
31. Effects of plasma treatment on the bioactivity of alkali-treated ceria-stabilised zirconia/alumina nanocomposite (NANOZR)10.3390/ijms21207476 ↗
32. Dominant albumin–surface interactions under independent control of surface charge and wettability10.1021/acs.langmuir.7b04117 ↗
33. Protein (BSA) adsorption on hydrophilic and hydrophobic surfaces
34. Competitive adsorption of collagen and bovine serum albumin—effect of the surface wettability10.1016/j.colsurfb.2003.10.015 ↗
35. A review on the wettability of dental implant surfaces ii: biological and clinical aspects10.1016/j.actbio.2014.03.032 ↗
36. The effect of titanium surface roughening on protein absorption, cell attachment, and cell spreading
37. Bone response to alteration of surface topography and surface composition of sandblasted and acid etched (SLA) implants10.1034/j.1600-0501.2002.130504.x ↗
38. Surface energy effects on osteoblast spatial growth and mineralization10.1016/j.biomaterials.2007.12.026 ↗
39. Influence of the roughness of dental implants obtained by additive manufacturing on osteoblastic adhesion and proliferation: a systematic review
40. Influence of surface treatments developed for oral implants on the physical and biological properties of titanium. (I) surface characterization10.1034/j.1600-0501.1997.080307.x ↗
41. Hydrogen desorption from sand-blasted and acid-etched titanium surfaces after glow-discharge treatment10.1002/1097-4636(200101)54:1<20::AID-JBM3>3.0.CO;2-Z ↗
42. Titanium hydride and hydrogen concentration in acid‐etched commercially pure titanium and titanium alloy implants: a comparative analysis of five implant systems10.1111/j.1600-0501.2010.01938.x ↗
43. Emerging factors affecting peri‐implant bone metabolism
44. Microbial dysbiosis, titanium release, and peri-implantitis10.1177/00220345241307939 ↗
45. Biofilm formation on dental implants with different surface micro‐topography: an in vitro study10.1111/clr.13455 ↗
46. Influence of dental implant surfaces on oral biofilms and host immune response10.1080/20002297.2025.2607199 ↗
47. Structure and composition of early biofilms formed on dental implants are complex, diverse, subject-specific and dynamic10.1038/s41522-024-00624-3 ↗