Effects of pulse voltage and deposition time on the adhesion strength of graded metal/carbon films deposited on bendable stainless steel foils by hybrid cathodic arc – glow discharge plasma assisted chemical vapor deposition
Source abstract
Abstract
Abstract Graded Ti/C composite films with carbon topcoats are prepared on bendable stainless steel foils by hybrid cathodic arc / glow discharge plasma-assisted chemical vapor deposition to simulate cardiovascular stents. Strong adhesion between the stainless steel substrate and carbon topcoat is achieved due to the graded Ti/C interface and it is further improved by increasing the pulse voltage. Moreover, the graded coating is more hydrophilic than the stainless steel substrate.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Diamond and Carbon-based Materials Research · Lubricants and Their Additives
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model10.1016/S0142-9612(02)00030-3 ↗
2. Self-expanding stainless steel biliary stents10.1148/radiology.170.3.2916066 ↗
3. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
4. Effect of mechanical surface pretreatment on metal ion release10.1016/S0142-9612(99)00200-8 ↗
5. Electrochemical Corrosion Behavior of biodegradable Mg–Y–RE and Mg-Zn-Zr Alloys in Ringer's solution and Simulated Body Fluid10.1016/j.corsci.2014.11.015 ↗
6. In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia10.1016/S0735-1097(97)00450-6 ↗
7. Sustained activation of vascular cells and leukocytes in the rabbit aorta after balloon injury10.1161/01.CIR.88.4.1788 ↗
8. Thermal oxidation of titanium: Evaluation of corrosion resistance as a function of cooling rate10.1016/j.matchemphys.2012.12.020 ↗
9. Electrodeposition of hydroxyapatite coating on magnesium for biomedical applications10.1007/s11998-011-9382-6 ↗
10. Effects of zirconium and oxygen plasma ion implantation on the corrosion behavior of ZK60 Mg alloy in simulated body fluids10.1016/j.corsci.2013.11.044 ↗
11. Enhanced antimicrobial properties, cytocompatibility, and corrosion resistance of plasma-modified biodegradable magnesium alloys10.1016/j.actbio.2013.10.012 ↗
12. Effects of zirconium and nitrogen plasma immersion ion implantation on the electrochemical corrosion behavior of Mg–Y–RE alloy in simulated body fluid and cell culture medium10.1016/j.corsci.2014.05.020 ↗
13. Effects of silicon plasma ion implantation on electrochemical corrosion behavior of biodegradable Mg–Y–RE Alloy10.1016/j.corsci.2012.11.037 ↗
14. Plasma modified Mg–Nd–Zn–Zr alloy with enhanced surface corrosion resistance10.1016/j.corsci.2013.09.007 ↗
15. Strategies to improve the corrosion resistance of microarc oxidation (MAO) coated magnesium alloys for degradable implants: Prospects and challenges10.1016/j.pmatsci.2013.08.002 ↗
16. Free radical functionalization of surfaces to prevent adverse responses to biomedical devices10.1073/pnas.1103277108 ↗
17. In vivo biocompatibility of a plasma-activated, coronary stent coating10.1016/j.biomaterials.2012.07.059 ↗
18. Graded metal carbon protein binding films prepared by hybrid cathodic arc - glow discharge plasma assisted chemical vapor deposition10.1016/j.surfcoat.2014.11.025 ↗
19. Regioselective covalent immobilization of recombinant antibody-binding proteins A, G, and L for construction of antibody arrays10.1021/ja402447g ↗
20. Late-phase inflammatory response as a feature of in-stent restenosis after drug-eluting stent implantation10.1097/MCA.0b013e32836222ec ↗
21. Pulmonary oxygenation, central hemodynamics and glomerular-filtration following cardiopulmonary bypass with colloid or non-colloid priming solution10.3109/14017438109100583 ↗
22. Plasma modified surfaces for covalent immobilization of functional biomolecules in the absence of chemical linkers: towards better biosensors and a new generation of medical implants10.1007/s12551-010-0028-1 ↗
23. Reduction of irreversible protein adsorption on solid surfaces by protein engineering for increased stability10.1074/jbc.M503665200 ↗
24. Tight-binding of albumin to glow-discharge treated polymers10.1163/156856292X00286 ↗
25. Covalently bound biomimetic layers on plasma polymers with graded metallic interfaces for in vivo implants10.1002/ppap.200900045 ↗
26. Recent progress in filtered vacuum arc deposition10.1016/S0257-8972(96)03023-X ↗
27. Bias voltage and incidence angle effects on the structure and properties of vacuum arc deposited TiN coatings10.1016/S0257-8972(00)00884-7 ↗
28. Plasma-surface modification of biomaterials10.1016/S0927-796X(02)00004-9 ↗
29. Tetrahedral bonding in amorphous carbon10.1088/0034-4885/59/12/002 ↗
30. Properties of tetrahedral amorphous-carbon prepared by vacuum-arc deposition10.1016/0925-9635(91)90011-X ↗
31. Evaluation of Corrosion Resistance and Cytocompatibility of Graded Metal Carbon Film on Ti and NiTi Prepared by Hybrid Cathodic Arc /Glow Discharge Plasma-Assisted Chemical Vapor Deposition10.1016/j.corsci.2015.04.022 ↗
32. Aksenov · Soviet Phys. Tech. Phys. · 1980 · 25
33. Control of stress and delamination in single and multi-layer carbon thin films prepared by cathodic arc and RF plasma deposition and implantation10.1016/j.surfcoat.2005.11.011 ↗
34. Raman spectroscopy study of DLC films prepared by RF plasma and filtered cathodic arc10.1016/j.surfcoat.2006.09.048 ↗
35. Ion-implanted polytetrafluoroethylene enhances Saccharomyces cerevisiae biofilm formation for improved immobilization10.1098/rsif.2012.0347 ↗
36. Titanium containing amorphous hydrogenated carbon films (aC: H/Ti): surface analysis and evaluation of cellular reactions using bone marrow cell cultures in vitro10.1016/S0142-9612(99)00135-0 ↗
37. Structural and mechanical characterization of duplex multilayer coatings deposited onto H13 tool steel10.1016/S2238-7854(12)70031-5 ↗
38. A stable cathode for the aprotic Li–O2 battery10.1038/nmat3737 ↗
39. Neuville · 2014 · 1