Surface characterization of poly(vinyl chloride) urinary catheters functionalized with acrylic acid and poly(ethylene glycol) methacrylate using gamma-radiation
Source abstract
Abstract
Abstract Poly(vinyl chloride) (PVC) urinary catheters were modified with either a single or binary graft of acrylic acid (AAc) and/or poly(ethylene glycol) methacrylate (PEGMA) using gamma-radiation from 60Co to obtain PVC-g-AAc, PVC-g-PEGMA, [PVC-g-AAc]-g-PEGMA, and [PVC-g-PEGMA]-g-AAc copolymers. The outer and inner surfaces of the modified catheters were characterized using scanning electron microscopy (SEM), confocal laser microscopy (CLM) and X-ray photoelectron spectroscopy (XPS). The XPS analyses, by examining the correlation between the variation of the C1s and O1s content at the catheter’s surface, revealed that the catheter’s surfaces were successfully grafted with the chosen compounds, with those that were binary grafted showing a slightly more covered surface as was evidenced by the disappearance of PVC’s Cl peak. The SEM and CLM analyses revealed that catheters that had been grafted with PEGMA had a rougher outer surface as compared to those that had only been grafted with AAc. In addition, these imaging techniques showed that the inner surface of the singly grafted catheters, whether they had been grafted with AAc or PEGMA, retained some smoothness at the analyzed grafting percentages, while the binary grafted catheters showed many protuberances and greater roughness on both outer and inner surfaces.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Urinary Tract Infections Management · Central Venous Catheters and Hemodialysis · Urinary Bladder and Prostate Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. Surface modification of polymers by grafting
2. Diagnosis management, and prevention of catheter associated urinary tract infections10.1016/j.idc.2013.09.002 ↗
3. Eliminating catheter-associated urinary tract infections in the intensive care unit: is it an attainable goal?10.1016/j.amjsurg.2014.08.013 ↗
4. Guidelines to prevent catheter-associated urinary tract infections: 1980–201010.1016/j.hrtlng.2011.08.001 ↗
5. Grafting on solid surfaces: grafting to and grafting from methods
6. Polymer surface with graft chains10.1016/S0079-6700(02)00032-1 ↗
7. Grafting: a versatile means to modify polymers: techniques: factors and applications10.1016/j.progpolymsci.2004.05.002 ↗
8. Surface functionalization of biomaterials
9. Spinks · 1964
10. Polyethylene glycol-coated biocompatible surfaces10.1002/1097-4636(20000905)51:3<343::AID-JBM7>3.0.CO;2-D ↗
11. Singly and binary grafted poly(vinyl chloride) urinary catheters that elute ciprofloxacin and prevent bacteria adhesion10.1016/j.ijpharm.2015.04.036 ↗
12. Sastri · 2014
13. Thermal degradation of gamma-irradiated PVC: I-dynamical experiments10.1016/j.polymdegradstab.2015.03.014 ↗
14. Beamson · 1992
15. Approaches to quantify amine groups in the presence of hydroxyl functional groups in plasma polymerized thin films10.1002/ppap.201400016 ↗
16. Radiation chemistry of polyvinyl chloride10.1021/j150580a045 ↗
17. Synthesis, characterization, and uses of novel-architecture copolymers through gamma radiation technique
18. Tailoring bulk and surface grafting of poly(acrylic acid) in electron-irradiated PVDF10.1016/j.polymer.2004.10.052 ↗
19. Effect of miro- and nano scale topography on the adhesion of bacterial cells to solid surfaces10.1128/AEM.03436-12 ↗