Corrosion and ion release behavior of Cu/Ti film prepared via physical vapor deposition in vitro as potential biomaterials for cardiovascular devices
Source abstract
Abstract
Abstract Cu/Ti films of various Cu/Ti ratios were prepared on a TiNi alloy via vacuum arc plasma deposition. The phase composition, structure, and concentration of elements were investigated via X-ray diffraction and X-photoelectron energy spectrum. The hemolysis ratio and platelet adhesion of the different films were characterized to evaluate blood compatibility. The corrosion and ion release behavior were investigated via a typical immersion test and electrochemical method. The growth of endothelial cells (ECs) was investigated, and methylthiazolyte-trazolium method was employed to evaluate the effect of Cu2+. The sophisticated films showed good compatibility. However, with increasing quality ratio of Cu/Ti, the hemolysis ratio increased, and some platelets started to break slightly. The Cu2+ release was gradually stabilized. The open circuit potential of the Cu/Ti film-modified samples was lower than that of the TiNi substrate. The polarization test result indicates that the passivation stability performance of Cu/Ti film samples is less than the TiNi substrate, and is favorable to Cu2+ release. The adhesion and proliferation of ECs would be inhibited with 10 wt.% Cu concentration of the film, and ECs would undergo apoptosis at >50 wt.% concentration. A Cu/Ti film with good compatibility and anti-endothelialization has potential applications for special cardiovascular devices.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Corrosion Behavior and Inhibition · Polymer Surface Interaction Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Long-duration temporary vena cava filter: a prospective 104-case multicenter study10.1016/j.jvs.2006.02.004 ↗
2. Inferior vena cave filter tilt and asymmetry: comparison of the over-the-wire stainless-steel and titanium Green field Inferior vena cave filters10.1016/S1051-0443(97)70706-1 ↗
3. Coronary stents: a materials perspective10.1016/j.biomaterials.2006.11.042 ↗
4. Development in intracoronary stents
5. In vivo investigation of blood compatibility of titanium oxide films10.1002/(SICI)1097-4636(199810)42:1<128::AID-JBM16>3.0.CO;2-H ↗
6. Passive stent coatings in the drug-eluting era
7. Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease10.1016/j.amjcard.2003.10.048 ↗
8. Hemocompatibility of titanium oxide films10.1016/S0142-9612(03)00046-2 ↗
9. Corrosion susceptibility Investigation of Ti–O films modified L-605 vascular stents by cyclic potentiodynamic polarzition measurement10.1016/j.surfcoat.2011.04.048 ↗
10. Biomaterial-associated thrombosis: roles of coagulation factors, complement, platelets and leukocytes10.1016/j.biomaterials.2004.01.023 ↗
11. Blood compatibility of sputter-deposited alumina films10.1002/jbm.820280212 ↗
12. Efficacy of anticoagulation post-inferior vena caval filter placement
13. Heparin and low-molecular-weight heparin: the seventh ACCP conference on antithrombotic and thrombolytic therapy10.1378/chest.126.3_suppl.188S ↗
14. Filter complications and their management
15. Copper toxicity, oxidative stress, and antioxidant nutrients10.1016/S0300-483X(03)00159-8 ↗
16. The lattice parameter of the α copper–titanium solid solution10.1107/S0021889870006787 ↗
17. Water quality determination of copper-2,9-dimethy-1,10-phenanthroline was conducted using spectrophotometric methods, UDC614.777:543.42:546.56.
18. Cytotoxicity of fusarium mycotoxins to mammalian cell cultures as determined by the MTT bioassay10.1016/j.fct.2005.01.016 ↗
19. Yang · 2003
20. Fretting study of surface modified Ni–Ti shape memory alloy10.1023/A:1014735225436 ↗
21. Hemocompatibility of surface-modified, silicon-incorporated, diamond-like carbon films10.1016/j.actbio.2008.07.031 ↗
22. Effect of copper on blood coagulation of Oreochromis mossambicus (Cichlidae)
23. Biomaterial associated thrombosis: roles of coagulation factors, complement, platelets and leukocytes10.1016/j.biomaterials.2004.01.023 ↗
24. Detection of shortened activated partial thromboplastin times: an evaluation of different commercial reagents10.1016/j.thromres.2007.05.006 ↗