journal article·2005-09

Life-limiting mechanisms in Ba-oxide, Ba-dispenser and Ba-Scandate cathodes

G. Gaertner, D. Barratt

Applied Surface Science· Volume 251· Issue 1-4
Publisher page

Abstract

Sufficient thermionic cathode life of several years in a vacuum electron tube environment at increased emission current density is one of the key parameters in advanced tube development. When improvements are investigated, accelerated life tests are applied in order to quantify their impact. Hence the investigation of cathode life limiting effects is the basis of accelerated life predictions. A quite general dependency of cathode life for different types is given by the dependence on operating temperature, due to the fact, that a lot of processes involved scale with temperature, such as chemical supply reactions, transport, diffusion, desorption and evaporation processes. Typically these processes are accelerated when the temperature is increased, and hence lifetime decreases. Other life limiting mechanisms are changes induced in the cathode when drawing current, which can be intrinsic changes, which are most pronounced in oxide cathodes and usually are irreversible, and/or surface changes by ion bombardment, where the ions are created by the extracted electrons via ionization of the residual gas. The removal of surface monolayers containing Ba by ion bombardment usually is reversible especially for Ba dispenser or I (impregnated) cathodes (by resupply of Ba), if the ion current is reduced for example, by lowering the residual gas pressure by continuous pumping. The third class of life limiting mechanisms is given by the presence of poisoness chemicals usually in form of gases in vacuum tubes, which can either affect chemical supply (dispensing) reactions or directly poison emission by adsorption of high work function surface monolayers on top of the emitting surface or f.i. oxidize base metal surfaces. This influence usually is the strongest in the activation and early life stage, where the amount of poisonous gases, e.g. containing oxygen, is highest, but is then continuously reduced by pumping. Usually a clean handling of the vacuum components and a good vacuum processing (baking and degassing, efficient pumping) is needed to avoid detrimental influences on cathode life.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Semiconductor materials and devices · Plasma Diagnostics and Applications · Advancements in Battery Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Gaertner · Appl. Surf. Sci. · 2003 · 215 · 7210.1016/S0169-4332(03)00282-4 ↗
2. An investigation to short time thermionic emission from oxide-coated cathodes10.1103/PhysRev.67.166 ↗
3. P.A.M.v.d. Heide, G. Gaertner, D. Barratt, IDW 2003, Fukuoka, Japan, Technical Digest CRT3-4.
4. D. Raasch, G. Gaertner, M. Pralle, K. Schlageter, Mass spectroscopy and gas poisoning of oxide cathodes, in: Proceedings of IVESC 2000, Orlando, Technical Digest D3.
5. D. den Engelsen, G. Gaertner, Model of dopant action in oxide cathodes, in: Proceedings of IVESC 2004, Beijing, D2, pp. 97–99 and this Journal.10.1109/IVESC.2004.1414148 ↗
6. B.M. Weon, G.S. Park, W.H. Kim, Asia Display/IDW 01, Technical Digest CRT3-3, 2001, p. 699.
7. M. Itazu, Life time estimation of cathode ray tubes, Japan Display (1988) 156–159.
8. Research on oxide coated cathodes
9. H.E. Kern, Emission and life of practical oxide cathodes as limited by diffusion and chemical reaction phenomena, Report on 23rd Annual Conference on Physical Electronics, 1963, pp. 106–113.
10. Aida · J. Appl. Phys. · 1993 · 74 · 648210.1063/1.355136 ↗
11. Roquais · Appl. Surf. Sci. · 2003 · 215 · 510.1016/S0169-4332(03)00318-0 ↗
12. Gaertner · Appl. Surf. Sci. · 1997 · 111 · 1110.1016/S0169-4332(96)00698-8 ↗
13. Uda · Appl. Surf. Sci. · 1999 · 146 · 3110.1016/S0169-4332(99)00067-7 ↗
14. G. Gaertner, H. Lydtin, European Patent 559283, 13.11.96, Kathode mit einem porösen Kathoden-element, Priority DE 5.3.1992.
15. G. Gaertner, H. Lydtin, European Patent EP 560436, 4.3.93, Kathode mit einem Festkörperelement, Priority DE 7.3.1992; US Patent 5592043, 7.1.1997, Cathode including a solid body.
16. Gaertner · Appl. Surf. Sci. · 1999 · 146 · 2210.1016/S0169-4332(99)00016-1 ↗
17. Gaertner · Appl. Surf. Sci. · 1999 · 146 · 1210.1016/S0169-4332(99)00041-0 ↗
18. G. Gaertner, P. Geittner, E. Klein, Elektrische Entladungsröhre oder Entladungslampe und Scandat-Vorratskathode, Priority German PA 19527723, 31.7.1995; European Patent EP 0757370, 5.7.2000.
19. G. Gaertner, P. Geittner, D. Raasch, D.U. Wiechert, Scandat-Vorratskathode, German Patent Application P 19961672.8, 20.12.1999.
20. Zhang · Appl. Surf. Sci. · 2003 · 215 · 2510.1016/S0169-4332(03)00320-9 ↗
21. W. Liu, K. Zhang, Y. Wang, K. Pan, X. Gu, J. Wang, J. Li, M. Zhou, Operating model for scandia doped matrix scandate cathode, in: Proceedings of IVESC 2004, Beijing, B3, pp. 62–64 and this Journal.
22. Raju · IEEE Trans. Electron. Devices · 1994 · 41 · 246010.1109/16.337464 ↗
23. A. Shih, J. Yater, C. Hor, Scandate cathode fundamentals: interactions of Ba, O and Sc on W, in: Proceedings of IVESC 2004, Beijing, B1, pp. 57–58.10.1109/IVESC.2004.1413957 ↗