journal article·2002-03Open access

Evaluation of a force sensor based on a quartz tuning fork for operation at low temperatures and ultrahigh vacuum

S. Hembacher, F.J. Giessibl, J. Mannhart

Applied Surface Science· Volume 188· Issue 3-4

Abstract

The noise performance of the force sensor is crucial for optimizing the resolution in non-contact atomic force microscopy. Sensing forces in vacuum and low temperatures is even more demanding than at ambient conditions. Here we analyze the noise performance and the sensitivity of a force sensor based on a quartz tuning fork of which one of the prongs is fixed (qPlus sensor). The noise characteristic of the qPlus sensor, optical and piezoresistive detection schemes at room temperature are compared and the qPlus sensor is investigated at low temperatures. The frequency variation of quartz tuning forks as a function of temperature is experimentally determined for the temperature range from 4 to 300 K.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Force Microscopy Techniques and Applications · Mechanical and Optical Resonators · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Binnig · Phys. Rev. Lett. · 1986 · 56 · 93010.1103/PhysRevLett.56.930 ↗
2. Giessibl · Science · 1995 · 267 · 6810.1126/science.267.5194.68 ↗
3. Tortonese · Appl. Phys. Lett. · 1993 · 62 · 84310.1063/1.108593 ↗
4. Giessibl · Appl. Phys. Lett. · 2000 · 76 · 147010.1063/1.126067 ↗
5. Meyer · Appl. Phys. Lett. · 1988 · 53 · 104510.1063/1.100061 ↗
6. Alexander · J. Appl. Phys. · 1989 · 65 · 16410.1063/1.342563 ↗
7. G.M. McClelland, R. Erlandson, S. Chiang, in: D.O. Thompson, D.E. Chimenti (Eds.), Review of Progress in Quantitative Nondestructive Evaluation, Vol. 6, 1987.
8. Giessibl · J. Vac. Sci. Technol. B · 1991 · 9 · 98410.1116/1.585441 ↗
9. H.J. Hug, Ph.D. Thesis, University of Basel, Switzerland, 1993.
10. Allers · Rev. Sci. Instrum. · 1998 · 69 · 22110.1063/1.1148499 ↗
11. Hug · Rev. Sci. Instrum. · 1999 · 70 · 362510.1063/1.1149970 ↗
12. Roseman · Rev. Sci. Instrum. · 2000 · 71 · 378210.1063/1.1290039 ↗
13. Volodin · Appl. Phys. A · 1998 · 66 · S30510.1007/s003390051151 ↗
14. Rychen · Rev. Sci. Instrum. · 1999 · 70 · 276510.1063/1.1149842 ↗
15. Giessibl · Science · 2000 · 289 · 42210.1126/science.289.5478.422 ↗
16. Giessibl · Appl. Surf. Sci. · 1999 · 140 · 35210.1016/S0169-4332(98)00553-4 ↗
17. F.J. Giessibl, H. Bielefeldt, S. Hembacher, J. Mannhart, Ann. Phys. 10 (2001).10.1002/1521-3889(200111)10:11/12<887::AID-ANDP887>3.0.CO;2-B ↗
18. Analog Devices. http://www.analog.com.
19. Beda · Sov. Phys. · 1997 · 9 · 1043
20. F.J. Giessibl, Habilitation Thesis, Augsburg University, 2000.
21. Rugar · Appl. Phys. Lett. · 1989 · 55 · 258810.1063/1.101987 ↗
22. Micro Crystal, Switzerland, http://www.mcrystal.ch.