Performance of surface on ultrafine grained Ti-0.2Pd in simulated body fluid
Source abstract
Abstract
Abstract Ti-0.2 wt% Pd (Ti-0.2Pd) which has high crevice corrosion resistance is highlighted for implant applications. In this work, Ti-0.2Pd alloy is subjected to equal channel angular pressing (ECAP) for grain refinement. The effect of the microstructure on the surface performance of Ti-0.2Pd in a simulated body fluid (SBF) adding bovine serum albumin is investigated. Heat-treated specimens including furnace cooled (FC) and water quenched (WQ) specimens are also prepared for comparison. The corrosion resistance is evaluated by the tests of potentiodynamic polarization and the measurement of electrochemical impedance spectroscopy (EIS). The composition and morphology of the surface after exposing to SBF 60 days were examined by X-ray photoelectronic spectroscopy (XPS), scanning electron microscope (SEM) and energy dispersive spectrometer (EDS). The results show an ultrafine grained microstructure with average grain size of 3.6 μm is obtained after ECAP. The ultrafine grained Ti-0.2Pd has higher corrosion resistance than AR(as-received), WQ and FC specimens. The quantitative analysis of the surface shows larger numbers of precipitations formed on ECAPed Ti-0.2Pd than those formed on heat-treated. The precipitation contains more oxygen, calcium and phosphorus on ECAPed specimen than those on other specimens. The Ca:P ratio is ranged from 1:0.7 to 1:4.4, no dependent on the specimen type. A larger Warburg resistance is obtained on WQ specimen indicating a denser layer formation on WQ specimen. The precipitation formed on WQ specimens is the least among three kinds of specimens. Palladium is not found on the surfaces after exposure to SBF.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Microstructure and corrosion of Pd-modified Ti alloys produced by powder metallurgy10.1016/j.corsci.2010.03.006 ↗
2. Corrosion resistant Ti-Pd surface alloys produced by high intensity pulsed plasma beams: part 1. Deposition by pulsed erosion and vacuum evaporation/pulsed implantation doping modes10.1016/j.surfcoat.2005.01.110 ↗
3. Effect of palladium on the corrosion behavior of titanium10.1016/j.corsci.2003.10.003 ↗
4. Eutectoid nanostructure formation in Ti-xPd alloys and its effects on mechanical properties and cytotoxicity10.1016/j.jallcom.2014.04.180 ↗
5. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments10.1016/j.biomaterials.2004.07.022 ↗
6. Fracture of sustained tensile-loaded Ti-0. 2% Pd alloy in acid and neutral fluoride solutions10.1016/j.msea.2005.12.006 ↗
7. Evaluation of hydrogen absorption properties of Ti-0. 2mass% Pd alloy in fluoride solutions10.1016/j.jallcom.2005.03.048 ↗
8. Electrochemical and cellular behavior of ultrafine-grained titanium in vitro10.1016/j.msec.2014.03.001 ↗
9. Corrosion resistance of ultra fine-grained Ti10.1016/j.scriptamat.2004.04.011 ↗
10. Comparative effect of grain size and texture on the corrosion behavior of commercially pure titanium processed by equal channel angular pressing10.1016/j.corsci.2009.08.017 ↗
11. Study of mechanical properties and corrosive resistance of ultrafine-grained alpha-titanium alloy Ti-5Al-2V10.1016/j.jallcom.2017.06.220 ↗
12. Corrosion behaviour of investment cast and friction stir processed Ti-6Al-4V10.1016/j.corsci.2010.05.026 ↗
13. Effect of multi-pass friction stir processing on the electrochemical and corrosion behavior of pure titanium in strongly acidic solutions10.1007/s11661-016-3854-3 ↗
14. Passive and electrochemical response of friction stir processed pure Titanium10.1016/j.jallcom.2017.02.095 ↗
15. Electrochemical and in vitro behavior of the nanosized composites of Ti-6Al-4V and TiO2 fabricated by friction stir process10.1016/j.apsusc.2017.06.141 ↗
16. Role of plastic deformation and microstructrue in the micro-electrochemical behavior of Ti-6Al-4V in sodium chloride solution10.1016/j.electacta.2012.12.029 ↗
17. Effect of thermo-mechanical processing on the corrosion resistance of Ti6Al4V alloys in biofluids10.1016/j.corsci.2009.08.014 ↗
18. Influence of fabrication process on electrochemical and surface properties of Ti-6Al-4V alloy for medical applications10.1016/j.electacta.2013.01.155 ↗
19. Improved corrosion behaviour of electron beam melted Ti-6Al-4V alloy in phosphate buffered saline10.1016/j.corsci.2017.05.003 ↗
20. Corrosion behavior of selective laser melted Ti-6Al-4V alloy in NaCl solution10.1016/j.corsci.2015.10.041 ↗
21. Corrosion behaviour of selective laser melted Ti-TiB biocomposite in simulated body fluid10.1016/j.electacta.2017.02.112 ↗
22. Distinction in corrosion resistance of selective laser melted Ti-6Al-4V alloy on different planes10.1016/j.corsci.2016.06.009 ↗
23. Heat treatment degrading the corrosion resistance of selective laser melted Ti-6Al-4V alloy10.1149/2.1481707jes ↗
24. In vitro fibroblast response to ultra fine grained titanium produced by a severe plastic deformation process
25. Enhanced osteoblast response to an equal channel angular pressing-processed pure titanium substrate with microrough surface topography10.1016/j.actbio.2009.04.038 ↗
26. Accelerated stem cell attachment to ultrafine grained titanium10.1016/j.actbio.2010.09.033 ↗
27. The influence of nano-scale surface roughness on bacterial adhesion to ultrafine-grained titanium10.1016/j.biomaterials.2010.01.071 ↗
28. The significance of crystallographic texture of titanium alloy substrates on pre-osteoblast responses10.1016/j.biomaterials.2006.02.027 ↗
29. Electrochemical impedance spectroscopy for studying passive layers on steel rebars immersed in alkaline solutions simulating concrete pores10.1016/j.electacta.2007.02.012 ↗
30. Composition and processing effects on the electrochemical characteristics of biomedical titanium alloys10.1016/j.corsci.2014.02.017 ↗
31. Corrosion behaviour of Ti-6Al-7Nb and Ti-6Al-4V ELI alloys in the simulated body fluid solution by electrochemical impedance spectroscopy10.1016/j.electacta.2006.06.018 ↗
32. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications10.1016/S0022-0728(99)00260-0 ↗
33. Substitution of the constant phase element by Warburg impedance for protective coating10.1016/j.corsci.2006.06.027 ↗
34. Determination of hydrogen diffusion coefficient in metal hydride electrode by modified Warburg impedance10.1016/S0925-8388(01)01569-9 ↗
35. NIST (National Institute of Standards and Technology) XPS Database Selected Element Search Menu. http://srdata.nist.gov/xps/selEnergyType.aspx .
36. Repassivation of titanium and surface oxide film regenerated in simulated bioliquid10.1002/(SICI)1097-4636(19980615)40:4<530::AID-JBM3>3.0.CO;2-G ↗
37. Influence of surface self-modification in Ringer’s solution on the passive behavior of titanium10.1002/jbm.a.30508 ↗
38. Kinetics of heterogeneous nucleation of calcium phosphates on anatase and rutile10.1006/jcis.1997.5329 ↗
39. Optimization of the Ti-0.2Pd alloy properties through heat treatment10.1016/S1471-5317(02)00023-8 ↗
40. Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy10.1016/S0010-938X(03)00186-0 ↗
41. Metal ion release from metal implants10.1016/j.msec.2004.08.018 ↗
42. Humphreys · 2004 · 12
43. Effects of titanium surface nodization with CaP incorporation on human osteoblastic response10.1016/j.msec.2013.01.002 ↗
44. Designing optimal calcium phosphate scaffold-cell combinations using an integrative model-based approach10.1016/j.actbio.2011.06.021 ↗
45. Association of collagen with calcium phosphate promoted osteogenic responses of osteoblast-like MG63 cells10.1016/j.colsurfb.2010.11.028 ↗