Ti1−Ag electrodes deposited on polymer based sensors
Source abstract
Abstract
Piezoelectric materials are interesting for the development of sensors and actuators for biomedical applications in areas such as smart prosthesis, implantable biosensors and biomechanical signal monitoring, among others. For acquiring or applying the electrical signal from/to the piezoelectric material, suitable electrodes can be produced from Ti based coatings with tailored multifunctional properties: conductivity and antibacterial characteristics through Ag inclusions. This work reports on Ti1−xAgx electrodes with different Ag/Ti atomic ratios deposited by dc and pulsed magnetron sputtering at room temperature on poly(vinylidene fluoride), PVDF. The X-ray diffraction (XRD) results revealed that the deposition conditions preserve the polymer structure and suggested the presence of crystalline Tiβ phase in pure titanium coating and fcc-Ag phase in pure silver coating. According to the results obtained from scanning electron microscopy (SEM) analysis, the coatings are homogeneous and no clusters were found; since β-PVDF is anisotropic, the deposited coatings replicate the underlying substrate surface. Sheet resistivity values show a typical behavior of a binary alloy system, with low resistivity values for coatings of zone 1 (Ti rich) and zone 3 (Ag rich) and a slightly higher resistivity values in zone 2. The piezoelectricity of the different samples show similar values.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Gas Sensing Nanomaterials and Sensors · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. XRD and FTIR analysis of Ti–Si–C–ON coatings for biomedical applications10.1016/j.surfcoat.2008.06.121 ↗
2. Osseointegration in skeletal reconstruction and rehabilitation
3. Biosensors: a tutorial review10.1109/MP.2006.1649009 ↗
4. Piezoresistive sensors for force mapping of hip-prostheses10.1016/j.sna.2013.03.013 ↗
5. Piezoresistive silicon thin film sensor array for biomedical applications10.1016/j.tsf.2011.01.300 ↗
6. Development of inkjet printed strain sensors10.1088/0964-1726/22/10/105028 ↗
7. Energy harvesting performance of piezoelectric electrospun polymer fibers and polymer/ceramic composites10.1016/j.sna.2013.03.023 ↗
8. Energy harvesting from piezoelectric materials fully integrated in footwear10.1109/TIE.2009.2028360 ↗
9. Electroactive phases of poly(vinylidene fluoride): determination, processing and applications10.1016/j.progpolymsci.2013.07.006 ↗
10. Radiation-resistant behavior of poly(vinylidene fluoride)/layered silicate nanocomposites10.1021/am800040q ↗
11. PVD-grown photocatalytic TiO2 thin films on PVDF substrates for sensors and actuators applications10.1016/j.tsf.2008.06.024 ↗
12. X-ray scattering experiments on sputtered titanium dioxide coatings onto PVDF polymers for self-cleaning applications10.1002/app.32744 ↗
13. Influence of albumin on the tribological behavior of Ag–Ti (C, N) thin films for orthopedic implants10.1016/j.msec.2013.09.031 ↗
14. TiAgx thin films for lower limb prosthesis pressure sensors: effect of composition and structural changes on the electrical and thermal response of the films10.1016/j.apsusc.2013.07.021 ↗
15. The relationship between inhibition of bacterial adhesion to a solid surface by sub-MICs of antibiotics and subsequent development of a biofilm10.1016/j.resmic.2005.02.004 ↗
16. In-vitro efficacy of a central venous catheter complexed with iodine to prevent bacterial colonization10.1093/jac/30.2.135 ↗
17. Biological actions of silver nanoparticles embedded in titanium controlled by micro-galvanic effects10.1016/j.biomaterials.2010.09.066 ↗
18. A study of the antimicrobial and tribological properties of TiN/Ag nanocomposite coatings10.1016/j.surfcoat.2009.05.012 ↗
19. Hybrid antimicrobial enzyme and silver nanoparticle coatings for medical instruments10.1021/am9002155 ↗
20. Electrical characterization of Ag:TiN thin films produced by glancing angle deposition10.1016/j.matlet.2013.10.044 ↗
21. Electrochemical behaviour of nanocomposite Agx:TiN thin films for dry biopotential electrodes10.1016/j.electacta.2014.01.082 ↗
22. Nanocomposite Ag:TiN thin films for dry biopotential electrodes10.1016/j.apsusc.2013.07.154 ↗
23. Structural and morphological evolution in TiAgx thin films as a function of in-vacuum thermal annealing
24. Ohring · 2002
25. Sustained self sputtering dc magnetron materials using dc magnetron10.1016/0042-207X(95)00096-8 ↗
26. Influence of silver content on the tribomechanical behavior on Ag-TiCN bioactive coatings10.1016/j.surfcoat.2011.09.059 ↗
27. Experimental study and thermodynamic assessment of the Ag–Ti system
28. The Ag–Ti (silver–titanium) system10.1007/BF02884876 ↗
29. Young · 1975
30. Influence of the β-phase content and degree of crystallinity on the piezo- and ferroelectric properties of poly(vinylidene fluoride)10.1088/0964-1726/19/6/065010 ↗
31. Preparation and characterization of TiN–Ag nanocomposite films10.1016/S0042-207X(02)00232-4 ↗
32. Advanced surface characterization of silver nanocluster segregation in Ag-TiCN bioactive coatings by RBS, GDOES, and ARXPS10.1007/s00216-013-7058-z ↗
33. Surface segregation in TiO2-based nanocomposite thin films10.1088/0957-4484/23/49/495701 ↗
34. Kasap · 2002