Biomimetic calcium phosphate coating of additively manufactured porous CoCr implants
Source abstract
Abstract
Abstract The aim of this work was to study the feasibility to use a biomimetic method to prepare biomimetic hydroxyapatite (HA) coatings on CoCr substrates with short soaking times and to characterize the properties of such coatings. A second objective was to investigate if the coatings could be applied to porous CoCr implants manufactured by electron beam melting (EBM). The coating was prepared by immersing the pretreated CoCr substrates and EBM implants into the phosphate-buffered solution with Ca 2+ in sealed plastic bottles, kept at 60 °C for 3 days. The formed coating was partially crystalline, slightly calcium deficient and composed of plate-like crystallites forming roundish flowers in the size range of 300–500 nm. Cross-section imaging showed a thickness of 300–500 nm. In addition, dissolution tests in Tris–HCl up to 28 days showed that a substantial amount of the coating had dissolved, however, undergoing only minor morphological changes. A uniform coating was formed within the porous network of the additive manufactured implants having similar thickness and morphology as for the flat samples. In conclusion, the present coating procedure allows coatings to be formed on CoCr and could be used for complex shaped, porous implants made by additive manufacturing.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental materials and restorations · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. Pin-on-disk wear behavior in a like- on-like configuration in a biological environment of high carbon cast and low carbon, forged Co–9Cr–Mo alloys10.1016/j.actamat.2006.10.005 ↗
2. Cementless femoral components should be made from cobalt chrome
3. Biomechanical implant fixation of CoCrMo coating inferior to titanium coating in a canine implant model10.1002/jbm.a.32709 ↗
4. Next generation orthopaedic implants by additive manufacturing using electron beam melting10.1155/2012/245727 ↗
5. Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: experimental studies in sheep10.1177/0885328211431857 ↗
6. Osseointegration enhancement by Zr doping of Co–Cr–Mo implants fabricated by electron beam melting10.1016/j.addma.2015.02.002 ↗
7. The effect of Ca/P concentration and temperature of simulated body fluid on the growth of hydroxyapatite coating on alkali-treated 316L stainless steel10.1016/S0142-9612(02)00154-0 ↗
8. Surface modification of titanium, titanium alloys, and related materials for biomedical application10.1016/j.mser.2004.11.001 ↗
9. Mechanical and histological evaluations of cobalt–chromium alloy and hydroxyapatite plasma-sprayed coatings in bone10.1007/BF00121256 ↗
10. Ti–6Al–4V/hydroxyapatite composite coatings prepared by thermal spray techniques10.1007/BF02646320 ↗
11. Plasma spraying of functionally graded hydroxyapatite/Ti–6Al–4V coatings10.1016/S0257-8972(03)00238-X ↗
12. Hydroxyapatite coating on a cobalt base alloy by investment casting10.1016/j.scriptamat.2005.12.059 ↗
13. Free form fabricated features on CoCr implants with and without hydroxyapatite coating in-vivo – a comparative study of bone contact and bone growth induction10.1007/s10856-011-4253-3 ↗
14. Histologic studies of failed dental implants: a retrieval analysis of four different oral implant designs10.1016/0267-6605(92)90015-L ↗
15. Bioactive ceramic prosthetic coatings10.1097/00003086-199203000-00014 ↗
16. Mohammadi · Long-term bone response to titanium implants coated with thin radiofrequent magnetron-sputtered hydroxyapatite in rabbits · 2004 · 19 · 498
17. Short-term bone response to titanium implants coated with thin radiofrequent magnetron-sputtered hydroxyapatite in rabbits10.1111/j.1708-8208.2003.tb00207.x ↗
18. Deposition of highly adhesive ZrO2 coating on Ti and CoCrMo implant materials using plasma spraying10.1016/S0142-9612(02)00376-9 ↗
19. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
20. Biological and medical significance of calcium phosphates10.1002/1521-3773(20020902)41:17<3130::AID-ANIE3130>3.0.CO;2-1 ↗
21. Biomineralized strontium-substituted apatite/titanium dioxide coating on titanium surfaces10.1016/j.actbio.2009.10.030 ↗
22. Bioactive titanium alloys prepared by chemical surface modification
23. Effect of the conditions of a biomimetic process on the formation of apatite on cobolt based alloys
24. Investigation of boundary conditions for biomimetic HA deposition on titanium oxide surfaces10.1007/s10856-009-3709-1 ↗
25. Bone tissue reactions to biomimetic ion-substituted apatite surfaces on titanium implants10.1098/rsif.2011.0808 ↗
26. Hydroxyapatite coating affects the Wnt signaling pathway during peri-implant healing in vivo10.1016/j.actbio.2013.12.012 ↗
27. Three-dimensional analytical techniques for evaluation of osseointegrated titanium implants10.1179/1743284714Y.0000000687 ↗
28. Biomimetic hydroxyapatite deposition on titanium oxide surfaces for biomedical application
29. Preparation of bioactive Ti and its alloys via simple chemical surface treatment10.1002/(SICI)1097-4636(199611)32:3<409::AID-JBM14>3.0.CO;2-B ↗
30. Characterization of the surface oxide film of a Co–Cr–Mo alloy after being located in a quasi-biological environment using XPS10.1016/S0169-4332(01)00551-7 ↗
31. Preparation of superhydrophilic microrough titanium implant surfaces by alkali treatment10.1007/s10856-010-4138-x ↗
32. Roughness induced dynamic changes of wettability of acid etched titanium implant modifications10.1016/j.biomaterials.2003.08.015 ↗
33. Formation and adhesion of biomimetic hydroxyapatite deposited on titanium substrates10.1016/j.actbio.2007.03.006 ↗
34. Ellingsen · 2003
35. Ion exchanges in apatites for biomedical applications10.1007/s10856-005-6979-2 ↗
36. Osteoclastic resorption of biomimetic calcium phosphate coatings in vitro10.1002/1097-4636(200108)56:2<208::AID-JBM1085>3.0.CO;2-R ↗
37. Preparation of hydroxyapatite coating on CoCrMo implant using an effective electrochemically-assisted deposition pretreatment10.1016/j.matchar.2011.08.002 ↗
38. Highly packed and aligned fluoride substituted hydroxyapatite via a surfactant-free process10.1002/jbm.b.31924 ↗
39. Incorporation of active ions into calcium phosphate coatings, their release behavior and mechanism10.1088/1748-6041/7/4/045018 ↗
40. The effects of inorganic additives to calcium phosphate on in vitro behavior of osteoblasts and osteoclasts10.1016/j.biomaterials.2010.01.002 ↗