Enhancement of wear and corrosion resistance of beta titanium alloy by laser gas alloying with nitrogen
Source abstract
Abstract
The relatively high elastic modulus coupled with the presence of toxic vanadium (V) in Ti6Al4V alloy has long been a concern in orthopaedic applications. To solve the problem, a variety of non-toxic and low modulus beta-titanium (beta-Ti) alloys have been developed. Among the beta-Ti alloy family, the quaternary Ti-Nb-Zr-Ta (TNZT) alloys have received the highest attention as a promising replacement for Ti6Al4V due to their lower elastic modulus and outstanding long term stability against corrosion in biological environments. However, the inferior wear resistance of TNZT is still a problem that must be resolved before commercialising in the orthopaedic market. In this work, a newly developed laser surface treatment technique was employed to improve the surface properties of Ti-35.3Nb-7.3Zr-5.7Ta alloy. The surface structure and composition of the laser-treated TNZT surface were examined by grazing incidence X-ray diffraction (GI-XRD) and X-ray photoelectron spectroscopy (XPS). The wear and corrosion resistance were evaluated by pin-on-plate sliding test and anodic polarisation test in Hanks' solution. The experimental results were compared with the untreated (or base) TNZT material. The research findings showed that the laser surface treatment technique reported in this work can effectively improve the wear and corrosion resistance of TNZT.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Metal and Thin Film Mechanics · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. Local intravascular effects of the nitinol wire blood clot filter10.1097/00004424-198804000-00009 ↗
2. Utilization of nickel–titanium shape memory alloy for stapes prosthesis10.1016/S0385-8146(96)00026-0 ↗
3. Bone healing and mineralization, implant corrosion, and trace metals after nickel–titanium shape memory metal intramedullary fixation10.1002/(SICI)1097-4636(19991215)47:4<472::AID-JBM3>3.0.CO;2-Z ↗
4. A new Ti–15Zr–4Nb–4Ta alloy for medical applications10.1016/S1359-0286(00)00025-5 ↗
5. Characterization of air-formed surface oxide film on Ti–29Nb–13Ta–4.6Zr alloy surface using XPS and AES10.1016/j.corsci.2008.06.002 ↗
6. Comparative corrosion study of Ti–Ta alloys for dental application10.1016/j.actbio.2009.05.037 ↗
7. Comparison of various properties between titanium-tantalum alloy and pure titanium for biomedical applications10.2320/matertrans.48.380 ↗
8. Influence of potential on the electrochemical behaviour of β titanium alloys in Hanks’ solution10.1016/j.actbio.2007.02.009 ↗
9. Laser diffusion nitriding of Ti–6Al–4V for improving hardness and wear resistance10.1016/j.apsusc.2011.08.114 ↗
10. Microstructural and mechanical characterization of biomedical Ti–Nb–Zr(–Ta) alloys10.1016/j.msea.2006.06.013 ↗
11. Bone bonding bioactivity of Ti metal and Ti–Zr–Nb–Ta alloys with Ca ions incorporated on their surfaces by simple chemical and heat treatment10.1016/j.actbio.2010.09.026 ↗
12. Effect of nitrogen addition and annealing temperature on superelastic properties of Ti–Nb–Zr–Ta alloys10.1016/j.msea.2010.07.052 ↗
13. Microstructural evolution and strengthening mechanisms in Ti–Nb–Zr–Ta, Ti–Mo–Zr–Fe and Ti–15Mo biocompatible alloys10.1016/j.msec.2004.12.013 ↗
14. High resolution transmission electron microscopy study of the hardening mechanism through phase separation in a β-Ti–35Nb–7Zr–5Ta alloy for implant applications10.1016/j.actbio.2009.11.010 ↗
15. A novel combinatorial approach to the development of beta titanium alloys for orthopaedic implants10.1016/j.msec.2004.12.010 ↗
16. Intra-granular alpha precipitation in Ti–Nb–Zr–Ta biomedical alloys10.1007/s10853-008-3148-2 ↗
17. Characterization of novel borides in Ti–Nb–Zr–Ta+ 2B metal-matrix composites10.1016/j.matchar.2008.07.011 ↗
18. Corrosion resistance and in vitro response of laser-deposited Ti–Nb–Zr–Ta alloys for orthopedic implant applications10.1002/jbm.a.32782 ↗
19. Wear resistance of laser-deposited boride reinforced Ti–Nb–Zr–Ta alloy composites for orthopedic implants10.1016/j.msec.2007.04.029 ↗
20. Micro-arc oxidation treatment to improve the hard-tissue compatibility of Ti–29Nb–13Ta–4.6Zr alloy10.1016/j.apsusc.2012.01.024 ↗
21. Formation and growth of calcium phosphate on the surface of oxidized Ti–29Nb–13Ta–4.6Zr alloy10.1016/j.biomaterials.2003.09.039 ↗
22. Bioactive calcium phosphate invert glass-ceramic coating on β-type Ti–29Nb–13Ta–4.6Zr alloy10.1016/S0142-9612(02)00316-2 ↗
23. Bioactive ceramic surface modification of β-type Ti–Nb–Ta–Zr system alloy by alkali solution treatment10.2320/matertrans.48.293 ↗
24. Enhancement of adhesive strength of hydroxyapatite films on Ti–29Nb–13Ta–4.6Zr by surface morphology control10.1016/j.jmbbm.2012.11.013 ↗
25. Characteristics of biomedical beta-type titanium alloy subjected to coating10.2320/matertrans.MRA2007207 ↗
26. Fabrication of hydroxyapatite film on Ti–29Nb–13Ta–4.6Zr using a MOCVD technique10.2320/matertrans.L-M2010821 ↗
27. Fatigue characteristics of bioactive glass-ceramic-coated Ti–29Nb–13Ta–4.6Zr for biomedical application10.1016/j.biomaterials.2003.09.108 ↗
28. Surface hardening of biomedical Ti–29Nb–13Ta–4.6Zr and Ti–6Al–4V ELI by gas nitriding10.1016/j.msea.2007.08.065 ↗
29. Wear and mechanical properties, and cell viability of gas-nitrided beta-type Ti–Nb–Ta–Zr system alloy for biomedical applications10.2320/matertrans.MRA2007210 ↗
30. Modifications of Surface Properties of Beta Ti by Laser Surface Treatment. Laser Materials Processing Conference
31. Tribological behaviour and microscopic wear mechanisms of UHMWPE sliding against thermal oxidation-treated Ti6Al4V10.1016/S0921-5093(00)00972-2 ↗
32. Contact and rubbing of flat surfaces10.1063/1.1721448 ↗
33. ASTM Standard G5-94 · 2004
34. In situ nitrided titanium alloys: microstructural evolution during solidification and wear10.1016/j.actamat.2014.09.026 ↗
35. Laser gas nitriding of pure titanium using CW and pulsed Nd:YAG lasers10.1016/j.surfcoat.2006.02.048 ↗
36. Wear of ion-implanted pure titanium against UHMWPE10.1016/0142-9612(89)90020-3 ↗
37. Potential of improving tribological performance of UHMWPE by engineering the Ti6Al4V counterfaces10.1016/S0043-1648(98)00356-1 ↗
38. Friction and wear properties of UHMWPE against ion implanted titanium alloy10.1016/j.surfcoat.2006.09.043 ↗
39. Bio-tribological properties of UHMWPE against surface modified titanium alloys10.1016/j.surfcoat.2012.05.033 ↗
40. Interactions between calcium, phosphate, and albumin on the surface of titanium10.1002/1097-4636(200104)55:1<45::AID-JBM70>3.0.CO;2-0 ↗
41. Corrosion resistance of anodic oxides on the Ti–50Zr and Ti–13Nb–13Zr alloys10.1016/j.electacta.2005.07.015 ↗
42. Corrosion and passivity of Ti–13%Nb–13%Zr in comparison to other biomedical implant alloys10.5006/1.3290281 ↗
43. Composition and processing effects on the electrochemical characteristics of biomedical titanium alloys10.1016/j.corsci.2014.02.017 ↗
44. Electrochemical characterization of biomedical titanium alloy Ti–35Nb–7Zr–5Ta
45. Titanium nitride oxidation chemistry: an X-ray photoelectron spectroscopy study10.1063/1.351465 ↗
46. Laser nitriding of metals10.1016/S0079-6425(00)00003-7 ↗
47. Effects of titanium nitride coatings on surface and corrosion characteristics of NiTi alloy10.4012/dmj.13.228 ↗