journal article·2025-12-12Open access

Application of a CdTe Photovoltaic Dosimeter to Therapeutic Megavoltage Photon Beams

Sang Hee Youn, Sangsu Kim, Jong Hoon Lee, Shinhaeng Cho

Applied Sciences· Volume 15· Issue 24

Abstract

Accurate real-time dosimetry is key in megavoltage radiotherapy; however, many detectors require external biasing or complex instrumentation. This study evaluated thin-film CdTe solar cells operating in photovoltaic (zero-bias) mode as medical dosimeters. Superstrate ITO/CdS/CdTe/Cu/Au devices were fabricated and irradiated with 6-MV photons from a clinical linear accelerator to 20 kGy cumulative dose. Electrical and dosimetric properties were assessed based on AM 1.5 current–voltage measurements, external quantum efficiency (EQE), dose linearity, dose-rate dependence, field-size dependence, percentage depth dose (PDD), and one-month reproducibility. With increasing dose (5–20 kGy), the open-circuit voltage and fill factor decreased by ~2–3%, the short-circuit current density by ~10%, retaining ~87% initial efficiency. Series and shunt resistances were stable, while EQE decreased uniformly (~5%), indicating degradation mainly from increased nonradiative recombination. Dose–signal linearity remained intact, and post-irradiation sensitivity loss was corrected with a single calibration factor. Dose-rate dependence was minor; low reverse bias (~3–7 V) enhanced response without nonlinearity. Field-size and PDD responses agreed with ionization chamber data within ~1%, and weekly stability was within ~1%. Parallel stacking of two cells increased signal nearly linearly. CdTe solar-cell detectors thus enable zero-bias, real-time, stable, and scalable dosimetry and strongly agree with reference standards.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Therapy and Dosimetry · solar cell performance optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Radiation Oncology, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea

Department of Radiation Oncology, Jeonbuk National University Hospital-Jeonbuk National University Medical School, Jeonju 54907, Republic of Korea

Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute, Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea

Global Health Technology Research Center, Korea University, Seoul 02841, Republic of Korea

Department of Radiation Oncology, St. Vincent’s Hospital, College of Medicine, The Catholic University of Korea, Suwon 16247, Republic of Korea

Department of Radiation Oncology, Chonnam National University Medical School, Gwangju 61469, Republic of Korea

Funding

National Research Foundation of Korea · Chonnam National University

References (29)

Show source-provided references
1. Trend analysis of radiation therapy incidents over seven years10.1016/j.radonc.2010.05.002 ↗
2. Radiosurgery for brain metastases: Changing practice patterns and disparities in the United States10.6004/jnccn.2017.7003 ↗
3. Radiotherapy errors and its verification approach
4. Lung stereotactic body radiation therapy (SBRT) dose gradient and PTV volume: A retrospective multicenter analysis10.1186/s13014-019-1334-9 ↗
5. Accuracy requirements and uncertainties in radiotherapy: A report of the International Atomic Energy Agency10.1080/0284186X.2016.1246801 ↗
6. Characterisation of a synthetic diamond detector for end-to-end dosimetry in stereotactic body radiotherapy and radiosurgery10.1016/j.phro.2021.10.002 ↗
7. Evaluation of the ArcCHECK QA system for IMRT and VMAT verification10.1016/j.ejmp.2012.04.005 ↗
8. Guidelines for safe practice of stereotactic body (ablative) radiation therapy10.1111/1754-9485.12336 ↗
9. The Canadian association of radiation oncology scope of practice guidelines for lung, liver and spine stereotactic body radiotherapy10.1016/j.clon.2012.04.006 ↗
10. Enhancing safety and quality through preplanning peer review for patients undergoing stereotactic body radiation therapy10.1016/j.prro.2015.09.009 ↗
11. A literature review of electronic portal imaging for radiotherapy dosimetry10.1016/j.radonc.2008.07.008 ↗
12. Characterization of a new MOSFET detector configuration for in vivo skin dosimetry10.1118/1.1924328 ↗
13. Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV X-ray beams10.1118/1.1785452 ↗
14. Thermoluminescence dosimetry and its applications in medicine—Part 2: History and applications
15. Thermoluminescence dosimetry and its applications in medicine—Part 1: Physics, materials and equipment
16. Optically stimulated luminescence in vivo dosimetry for radiotherapy: Physical characterization and clinical measurements in (60)Co beams10.1088/0031-9155/56/18/018 ↗
17. Practical time considerations for optically stimulated luminescent dosimetry (OSLD) in total body irradiation10.1007/s13246-016-0504-4 ↗
18. In vivo dosimetry for mammography with and without lead apron using the glass dosimeters10.14316/pmp.2015.26.2.93 ↗
19. Clinical application of glass dosimeter for in vivo dose measurements of total body irradiation treatment technique10.1016/j.radmeas.2010.08.013 ↗
20. Development of a dosimetry system for therapeutic X-rays using a flexible amorphous silicon thin-film solar cell with a scintillator screen10.1002/mp.15664 ↗
21. Flexible real-time skin dosimeter based on a thin-film copper indium gallium selenide solar cell for electron radiation therapy10.1002/mp.16191 ↗
22. Composition study of CdTe charges synthesized by the travelling heater method10.1109/TNS.2007.903171 ↗
23. Energy weighting technique in Quantum Computed Tomography using a MPGD10.1088/1748-0221/6/02/C02002 ↗
24. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications10.1016/j.nima.2014.10.079 ↗
25. Vision 20/20: Single photon counting X-ray detectors in medical imaging10.1118/1.4820371 ↗
26. CdTe x-ray sensing driven by electron beam from field emitters10.1116/1.2432356 ↗
27. Deposition of Cl-doped CdTe polycrystalline films by close-spaced sublimation10.1002/pssc.201400257 ↗
28. Gamma-ray tolerance of CdS/CdTe photodiodes for radiation tolerant compact image sensor with field emitter array10.1002/pssc.201510229 ↗
29. Radiation hardness studies of CdTe thin films for clinical high-energy photon beam detectors10.1016/j.nima.2007.11.017 ↗