This article proposes a topology of the secondary reconfigurable inverter and the corresponding fault-tolerant control strategy. When the secondary reconfigurable inverter is operating normally, its topology structure is the TPSS circuit. When the power semiconductor devices in the inverter are faulty, the inverter circuit needs to be reconfigured. After removing the faulty power semiconductor devices, the remaining power semiconductor devices and the DC side powers are reconstructed as the TPFS structure to keep the system running normally. This article also proposes a switch-pulse-resetting algorithm. This paper adopts the control strategy connecting the constant-voltage, constant-frequency control method with the switch pulse resetting algorithm. It need not change the control algorithm when the proposed reconfigurable inverter is transformed from the normal running state into the faulty running state. The inverter dependability is greatly improved. Finally, the feasibility and effectiveness of the proposed second reconfigurable inverter topology and control strategy are verified by simulation and experiment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Multilevel Inverters and Converters · Silicon Carbide Semiconductor Technologies · Advanced DC-DC Converters

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Automation, Central South University, Changsha 410083, China

College of Electrical and Information Engineering, Hunan University, Changsha 410082, China

Funding

National Natural Science Foundation of China

References (38)

Show source-provided references
1. Steady-State Dead-Time Compensation in VSI10.1109/TIE.2016.2586680 ↗
2. Stability Analysis and Decentralized Control of Inverter-Based AC Microgrid
3. Ballestín-Fuertes, J., Muñoz-Cruzado-Alba, J., Sanz-Osorio, J.F., Hernández-Callejo, L., Alonso-Gómez, V., Morales-Aragones, J.I., Gallardo-Saavedra, S., Martínez-Sacristan, O., and Moretón-Fernández, Á. (2020). Novel Utility-Scale Photovoltaic Plant Electroluminescence Maintenance Technique by Means of Bidirectional Power Inverter Controller. Appl. Sci., 10.10.3390/app10093084 ↗
4. Sliding Mode Approach Applied to Sensorless Direct Torque Control of Cage Asynchronous Motor Via Multi-Level Inverter
5. Survey on Fault-Tolerant Techniques for Power Electronic Converters10.1109/TPEL.2014.2304561 ↗
6. Modeling Methodology and Fault Simulation of Distribution Networks Integrated with Inverter-Based DG
7. Fault-Tolerant Control Strategies for T-Type Three-Level Inverters Considering Neutral-Point Voltage Oscillations10.1109/TIE.2018.2842731 ↗
8. A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters10.1109/TIA.2009.2027535 ↗
9. FPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems10.1109/TIE.2008.2005244 ↗
10. Fault-Tolerant Permanent Magnet Motor Drive Topologies for Automotive X-By-Wire Systems10.1109/TIA.2009.2039982 ↗
11. Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives10.1109/TPEL.2011.2135866 ↗
12. Multiphase Power Converter Drive for Fault-Tolerant Machine Development in Aerospace Applications
13. Optimized Control Strategy Based on Dynamic Redundancy for the Modular Multilevel Converter10.1109/TPEL.2014.2305663 ↗
14. Adaptive SVM to compensate DC-link voltage ripple for four-switch three-phase voltage-source inverters10.1109/63.774214 ↗
15. Hu, S., Liu, G., Jin, N., and Guo, L. (2018). Constant-Frequency Model Predictive Direct Power Control for Fault-Tolerant Bidirectional Voltage-Source Converter with Balanced Capacitor Voltage. Energies, 11.10.3390/en11102692 ↗
16. Comprehensive Analysis and Reduction of Torque Ripples in Three-phase Four-switch Inverter-fed PMSM Drives Using Space Vector Pulse-width Modulation
17. Investigation of a Four-Switch Four-Leg Inverter: Modulation, Control, and Application to an IPMSM Drive10.1109/TPEL.2018.2869491 ↗
18. Modeling, Modulation and Control of the Three-Phase Four-Switch PWM Rectifier under Balanced Voltage10.1109/TPEL.2015.2480539 ↗
19. Space-Vector-Based Hybrid PWM Strategy for Reduced DC-Link Capacitor Current Stress in the Post-Fault Grid-Connected Three-Phase Rectifier10.1109/TIE.2016.2547367 ↗
20. The Comprehensive Design and Optimization of the Post-Fault Grid-Connected Three-Phase PWM Rectifier10.1109/TIE.2015.2494854 ↗
21. A Control Strategy for Four-Switch Three-Phase Brushless DC Motor Using Single Current Sensor10.1109/TIE.2009.2014307 ↗
22. Analytical Investigation of an Induction Motor Fed from Four-Switch VSI with a New Space Vector Modulation Strategy10.1109/TEC.2005.858067 ↗
23. A Current Distortion Compensation Scheme for Four-Switch Inverters10.1109/TPEL.2008.2011552 ↗
24. A Comprehensive Investigation of Four-Switch Three-Phase Voltage Source Inverter Based on Double Fourier Integral Analysis10.1109/TPEL.2011.2119381 ↗
25. A General PWM Strategy for Four-Switch Three-Phase Inverters10.1109/TPEL.2006.882964 ↗
26. A Current Control Scheme of Brushless DC Motors Driven by Four-Switch Three-Phase Inverters10.1109/JESTPE.2016.2637383 ↗
27. A Performance Investigation of a Four-Switch Three-Phase Inverter-Fed IM Drives at Low Speeds Using Fuzzy Logic and PI Controllers10.1109/TPEL.2016.2583660 ↗
28. Application of Four-Switch-Based Three-Phase Grid-Connected Inverter to Connect Renewable Energy Source to a Generalized Unbalanced Microgrid System10.1109/TIE.2012.2202350 ↗
29. Single DC source three-phase multilevel inverter using reduced number of switches10.1049/iet-pel.2013.0319 ↗
30. Finite States Model Predictive Control for Fault-Tolerant Operation of a Three-Phase Bidirectional AC/DC Converter Under Unbalanced Grid Voltages10.1109/TIE.2017.2686342 ↗
31. Fault-Tolerant Neutral-Point-Clamped Converter Solutions Based on Including a Fourth Resonant Leg10.1109/TIE.2010.2069075 ↗
32. Three-Level Converter Topologies With Switch Breakdown Fault-Tolerance Capability10.1109/TIE.2008.917072 ↗
33. Modulation Strategies for Fault-Tolerant Operation of H-Bridge Multilevel Inverters10.1109/ISIE.2006.295709 ↗
34. Liu, Y., Li, D., Jin, Y., Wang, Q., and Song, W. (2018). Research on Unbalance Fault-Tolerant Control Strategy of Modular Multilevel Photovoltaic Grid-Connected Inverter. Energies, 11.10.3390/en11061368 ↗
35. Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter Systems10.1109/TIA.2013.2269531 ↗
36. Reliability Improvement of a T-Type Three-Level Inverter with Fault-Tolerant Control Strategy10.1109/TPEL.2014.2325891 ↗
37. An Embedded Closed-Loop Fault-Tolerant Control Scheme for Nonredundant VSI-Fed Induction Motor Drives10.1109/TPEL.2016.2582834 ↗
38. Fault Analysis and Fault-Tolerant Design for Parallel Redundant Inverter Systems in Case of IGBT Short-Circuit Failures10.1109/JESTPE.2018.2844092 ↗