journal article·2021-04-17Open access

A Transformer-Less Buck-Boost Grid-Tied Inverter with Low Leakage-Current and High Voltage-Gain

Chien-Hsuan Chang, Yi-Fan Chen

Applied Sciences· Volume 11· Issue 8

Abstract

To improve the efficiency of photovoltaic (PV) grid-tied systems and simplify the circuit structure, many pseudo DC-link inverters have been proposed by combining a sinusoidal pulse-width modulation (SPWM) controlled buck-boost converter and a low-frequency polarity unfolder. However, due to the non-ideal characteristics of power diodes, the voltage-gain of a buck-boost converter is limited. To meet the needs of grid-connected systems with low input voltage and 220 Vrms utility, this paper uses two two-switch buck-boost converters with coupled inductors to develop a transformer-less buck-boost grid-tied inverter with low leakage-current and high voltage-gain. The proposed inverter is charging on the primary side of the coupled inductor and discharging in series on the primary side and the secondary side so that the voltage-gain can be greatly increased. Furthermore, the utility line can be connected to the negative end of the PV array to suppress leakage current, and the unfolding circuit can be simplified to reduce the conduction losses. High-frequency switching is only performed in one metal-oxide-semiconductor field-effect transistor (MOSFET) in each mode, which can effectively improve conversion efficiency. A prototype was implemented to obtain experimental results and to prove the validity of the proposed circuit structure.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photovoltaic System Optimization Techniques · Advanced DC-DC Converters · Multilevel Inverters and Converters

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical Engineering, I-Shou University, Dashu District, Kaohsiung City 84001, Taiwan

Funding

Ministry of Science and Technology, Taiwan

References (24)

Show source-provided references
1. A single-stage single-phase transformer-less doubly grounded grid-connected PV interface10.1109/TEC.2008.2006551 ↗
2. Low-cost semi-Z-source inverter for single-phase photovoltaic systems10.1109/TPEL.2011.2148728 ↗
3. Design and analysis of a grid-connected photovoltaic power system10.1109/TPEL.2009.2036432 ↗
4. A novel single-stage full-bridge buck-boost inverter10.1109/TPEL.2003.820583 ↗
5. Improved dual boost inverter with half cycle modulation10.1109/TPEL.2016.2592979 ↗
6. Dual-buck-structured high-reliability and high efficiency single-stage buck–boost inverters10.1109/TIE.2017.2752145 ↗
7. An interleaved high-power flyback inverter for photovoltaic applications10.1109/TPEL.2014.2332503 ↗
8. Grid-connected forward microinverter with primary-parallel secondary-series transformer10.1109/TPEL.2014.2365760 ↗
9. Chang, C.H., Cheng, C.A., Cheng, H.L., and Wu, Y.T. (2020). An active-clamp forward inverter featuring soft switching and electrical isolation. Appl. Sci., 10.10.3390/app10124220 ↗
10. Novel grid-connected photovoltaic inverter
11. Derivation, analysis, and implementation of a boost–buck converter-based high-efficiency PV inverter10.1109/TPEL.2011.2163805 ↗
12. Chang, C.H., Cheng, C.A., Chang, E.C., and Cheng, H.L. (2015, January 1–5). Design and implementation of a two-switch buck-boost typed inverter with universal and high-efficiency features. Proceedings of the 2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia), Seoul, Korea.10.1109/ICPE.2015.7168158 ↗
13. Chang, C.H., Cheng, C.A., and Cheng, H.L. (2018, January 20–24). An interleaved buck-cascaded buck-boost inverter for PV grid-connection applications. Proceedings of the 2018 International Power Electronics Conference (IPEC-Niigata 2018-ECCE Asia), Niigata, Japan.10.23919/IPEC.2018.8507516 ↗
14. A single-phase transformerless inverter with charge pump circuit concept for grid-tied PV applications10.1109/TIE.2016.2645162 ↗
15. Topology review and derivation methodology of single phase transformerless photovoltaic inverters for leakage current suppression10.1109/TIE.2015.2399278 ↗
16. H6 transformerless full-bridge PV grid-tied inverters10.1109/TPEL.2013.2260178 ↗
17. Modified single-phase single-stage grid-tied flying inductor inverter with MPPT and suppressed leakage current10.1109/TIE.2017.2719610 ↗
18. Neutral point clamped transformerless grid connected inverter having voltage buck–boost capability for solar photovoltaic systems10.1049/iet-pel.2014.0873 ↗
19. Optimization of SiC-based H5 and conergy-NPC transformerless PV inverters10.1109/JESTPE.2014.2332253 ↗
20. Recent advances in single-phase transformerless photovoltaic inverters10.1049/iet-rpg.2015.0101 ↗
21. An optimized transformerless photovoltaic grid-connected inverter10.1109/TIE.2010.2054056 ↗
22. Transformerless inverter for single-phase photovoltaic systems10.1109/TPEL.2007.892120 ↗
23. A new high-efficiency single-phase transformerless PV inverter topology10.1109/TIE.2009.2024092 ↗
24. Chang, C.H., and Ho, K.H. (2020). A transformer-less high-gain inverter with step-up/down and single energy-processing features. IEEE Emerg. Sel. Top. Power Electron, accepted.10.1109/JESTPE.2020.3023107 ↗