Study on Roof Ventilation and Optimized Layout of Photovoltaics for Semi-Outdoor Main Transformer Rooms in Substations
Source abstract
Abstract
In the context of global decarbonization goals and increasing urban electricity demand, the green transformation of power industry buildings to enhance the utilization of renewable energy represents a significant contribution to sustainable social development. Rooftop photovoltaic (PV) systems can reduce unnecessary radiative heat gain and generate clean electricity to support this transition; however, they also alter the rooftop wind environment. Deploying rooftop PV systems requires well-planned design strategies to optimize renewable energy production while ensuring adequate natural ventilation, particularly for semi-outdoor main transformer rooms where ventilation and heat dissipation are crucial for safe substation operations. This concept was tested at a 220 kV substation in Guangzhou, China, using Computational Fluid Dynamics (CFD) and PVSYST to assess the impact of different rooftop PV systems on natural ventilation and power generation. The analysis showed that while the horizontal PV system achieved the highest energy output, it also resulted in a wind speed reduction of 13.2% or 11.8%. In contrast, the 10° symmetrical PV system offers the most balanced solution, with only a 0.6% decrease in ventilation performance but at the cost of a 13.87% reduction in PV output. The unilateral pitched PV system results in ventilation losses of less than 4%, and the power generation loss is also kept below 4%. However, this configuration may lead to increased wind loads. This approach can be developed into a practical design tool to further support the integration of PV systems in substation green retrofitting projects.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Thermal Analysis in Power Transmission · Icing and De-icing Technologies · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Power Grid Planning Research Center of Guangdong Power Grid Co., Ltd., Guangzhou 510220, China
School of Architecture, South China University of Technology, Guangzhou 510641, China
State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510630, China
Funding
Science and Technology Project of China Southern Power Grid Co., Ltd.
References (36)
Show source-provided references
1. United States Joint Economic Committee (2025, March 30). Energy Efficiency Is a Bright Idea, Available online: https://www.jec.senate.gov/public/index.cfm/democrats/2007/6/energy-efficiency-is-a-bright-idea-_395.
2. Del Borghi, A., Spiegelhalter, T., Moreschi, L., and Gallo, M. (2021). Carbon-Neutral-Campus Building: Design Versus Retrofitting of Two University Zero Energy Buildings in Europe and in the United States. Sustainability, 13.10.3390/su13169023 ↗
3. Present and future energy consumption of buildings: Challenges and opportunities towards decarbonisation10.1016/j.prime.2021.100002 ↗
4. The China Association of Building Energy Efficiency (2025, March 30). Research Report on Carbon Emissions in the Urban and Rural Construction Sector. Available online: https://www.cabee.org/site/content/25289.html.
5. (2025, March 30). Xinhua News Agency: China’s Policies and Actions for Addressing Climate Change, Available online: https://www.gov.cn/zhengce/2021-10/27/content_5646697.htm.
6. Green Warehouses: The Benefits, Challenges and Strategies of Industrial Building Decarbonization10.38124/ijisrt/IJISRT24MAR1644 ↗
7. Reis, D.C., De Domenico, A.T., Lopes, L., and Almeida, M. (2023). Strategies and Actions for Achieving Carbon Neutrality in Portuguese Residential Buildings by 2050. Sustainability, 15.10.3390/su152115626 ↗
8. (2025, March 30). Solar Energy: Applications, Trends Analysis, Bibliometric Analysis and Research Contribution to Sustainable Development Goals (SDGs). Available online: https://www.mdpi.com/2071-1050/15/2/1418.10.3390/su15021418 ↗
9. Notice of the General Office of the State Council (2024). Work Plan for Accelerating Energy Conservation and Carbon Reduction in the Building Sector, National Development and Reform Commission and the Ministry of Housing and Urban-Rural Development.
10. Che, W., Wang, Y., Zhu, W., Hong, L., Fang, C., Wu, H., and Liu, J. (2024). A Review of Carbon Emission Reduction During the Operation Stage of Substations. Sustainability, 16.10.3390/su162210017 ↗
11. A Review of the Solar City Concept and Methods to Assess Rooftop Solar Electric Potential, with an Illustrative Application to the City of Seoul10.1016/j.rser.2014.08.023 ↗
12. Construction Plan for Rooftop Distributed PV Systems in Urban 110 kV Indoor Substations
13. (2025, March 30). Shenzhen Power Grid Construction Accelerates Across the Board: Number of New Substations and Main Transformer Capacity in 2023 Both Reach Highest Levels in a Decade—Shenzhen News Network. Available online: https://www.sznews.com/news/content/2024-01/19/content_30707543.htm.
14. Research on the Application of Photovoltaic Power Generation Technology in Green and Energy-Efficient Renovation Projects of Substations
15. Corti, P., Bonomo, P., and Frontini, F. (2023). Paper Review of External Integrated Systems as Photovoltaic Shading Devices. Energies, 16.10.3390/en16145542 ↗
16. Calculation of Noise Field in Main Transformer Room of Indoor Substation Based on Thermal-Acoustic Coupling10.1016/j.energy.2024.131046 ↗
17. Numerical Simulation and Optimization of Ventilation and Heat Dissipation in Main Transformer Room of Semi-Indoor Substations10.1016/j.applthermaleng.2025.126105 ↗
18. Chen, C.-M., Lin, Y.-P., Chung, S.-C., and Lai, C.-M. (2022). Effects of the Design Parameters of Ridge Vents on Induced Buoyancy-Driven Ventilation. Buildings, 12.10.3390/buildings12020112 ↗
19. Study on the Optimal Layout of Roof Vents and Rooftop Photovoltaic of the Industrial Workshop10.1016/j.buildenv.2024.111624 ↗
20. Numerical Investigation of the Effects of Different Influencing Factors on Thermal Performance of Naturally Ventilated Roof10.1016/j.energy.2023.130039 ↗
21. Validation of Computational Fluid Dynamics (CFD) Model of a Building Integrated Photovoltaic/Thermal (BIPV/T) System10.1016/j.egypro.2015.11.359 ↗
22. Experimental and Numerical Performance Analysis of a Converging Channel Heat Exchanger for PV Cooling10.1016/j.enconman.2015.06.018 ↗
23. Analyzing the interactions between photovoltaic system and its ambient environment using CFD techniques: A review10.1016/j.enbuild.2023.113394 ↗
24. Improvement of the Photovoltaic Panel Cooling by Natural Air Ventilation10.1002/ep.14304 ↗
25. Optimizing air inlet designs for enhanced natural ventilation in indoor substations: A numerical modelling and CFD simulation study10.1016/j.csite.2024.104408 ↗
26. Numerical simulation and optimisation design for ventilation and heat dissipation in high-temperature and high-load indoor substations10.1016/j.csite.2024.104502 ↗
27. Wang, Y., Jin, X., Zhang, J., Zeng, C., Gao, X., Zhao, L., and Sha, S. (2024). Scheme Design and Energy-Saving Optimization of Cold and Heat Energy Supply System for Substation Main Control Building in Cold Area. Appl. Sci., 14.10.3390/app14041562 ↗
28. (2021). Photovoltaic System Performance Monitoring—Guidelines for Measurement, Data Exchange and Analysis (Standard No. IEC 61724).
29. Local-Scale Forcing Effects on Wind Flows in an Urban Environment: Impact of Geometrical Simplifications10.1016/j.jweia.2017.08.001 ↗
30. CFD Modeling of Natural Ventilation in a Void Connected to the Living Units of Multi-Storey Housing for Thermal Comfort10.1016/j.enbuild.2017.03.035 ↗
31. AIJ Guidelines for Practical Applications of CFD to Pedestrian Wind Environment around Buildings10.1016/j.jweia.2008.02.058 ↗
32. Revisiting RANS Turbulence Modelling Used in Built-Environment CFD Simulations10.1016/j.buildenv.2023.110333 ↗
33. (2025, March 31). Guangzhou Weather. Available online: http://www.tqyb.com.cn/gz/climaticprediction/bulletin/.
34. Wu, Y. (2023). Research on Urban Block Ventilation Optimization Method Based on Surrogate Models—Taking Guangzhou as an Example. [Ph.D. Thesis, Wuhan University].
35. Design Strategies for Building Rooftop Photovoltaic Systems: Efficiency and Grid Integration10.1016/j.jobe.2024.111693 ↗
36. Xu, D., Zhang, L., Wang, H., Wang, K., and Zhang, W. (2024). An Investigation of the Ventilation Systems of Whole-Indoor Urban Substations. Buildings, 14.10.3390/buildings14123749 ↗