Current Flow Analysis of PV Arrays under Voltage Mismatch Conditions and an Inverter Failure
Source abstract
Abstract
In PV (Photovoltaic) systems, the PV array is a structure in which many PV strings are connected in parallel. The voltage mismatch between PV strings, in which PV modules are connected in a series, occurs due to a voltage decrease in some modules. In this paper, research on the electrical characteristics of PV arrays due to a voltage mismatch was conducted. Considering the voltage mismatch, experiments on partial shading, the non-uniformity of irradiance, and the failure of bypass diodes were conducted on the PV module level. It was confirmed that the open-circuit voltage greatly decreased due to the failure of bypass diodes, which is among the causes of voltage mismatch. From the simulation results at the PV array level, it can be seen that a reverse current flowed into the low-potential string, which includes PV modules, causing the failure of the bypass diodes. Measuring the reverse current at one low-potential string, it was found that, in four parallel circuits, the reverse current was 12 A. For this reason, in large PV plants, an overcurrent can flow into the fuse due to the potential difference between strings, causing an output decrease of PV plants and the burnout of fuses.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Photovoltaic System Optimization Techniques · Solar Thermal and Photovoltaic Systems · solar cell performance optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Photovoltaics Laboratory, New and Renewable Energy Institute, Korea Institute of Energy Research, Daejeon 34129, Korea
References (22)
Show source-provided references
1. Intelligent PV module for grid-connected PV system10.1109/TIE.2006.878327 ↗
2. Power losses in long string and parallel-connected short strings of series-connected silicon based photovoltaic modules due to partial shading conditions10.1109/TEC.2011.2175928 ↗
3. Modeling, analysis and comparison of solar photovoltaics array configuration under partial shading conditions10.1016/j.solener.2015.07.039 ↗
4. Forecasting photovoltaic array power production subject to mismatch losses10.1016/j.solener.2010.04.009 ↗
5. Shade diffusion of partial shaded PV array by using odd-even structure10.1016/j.solener.2019.01.076 ↗
6. Distributed maximum power point tracking of photovoltaic array: Novel approach and system analysis10.1109/TIE.2008.924035 ↗
7. A real maximum power point tracking method for mismatching compensation in PV array under partially shaded conditions10.1109/TPEL.2010.2089537 ↗
8. Analysis model of mismatch power losses in PV systems10.1115/1.3097275 ↗
9. Mismatch losses in PV power plants10.1016/j.solener.2013.11.026 ↗
10. KS C 8567:2019, Photovoltaic combiner box.
11. IEC TS 62257-7-1:2010, Recommendations for small renewable energy and hybrid systems for rural electrification—Part 7-1: Generators—Photovoltaic generators.
12. Diagnostic architecture: A procedure based on the analysis of the failure causes applied to photovoltaic plants10.1016/j.measurement.2015.02.023 ↗
13. Fault detection and monitoring systems for photovoltaic installations: A review10.1016/j.rser.2017.09.101 ↗
14. Klise, G., Lavrova, O., and Gooding, R. (2018). PV System Component Fault and Failure Compilation and Analysis (No. SAND-2018-1743), Sandia National Lab. (SNL-NM).10.2172/1424887 ↗
15. Köntges, M., Oreski, G., Jahn, U., Herz, M., Hacke, P., and Weiß, K.A. (2017). Assessment of Photovoltaic Module Failures in the Field: International Energy Agency Photovoltaic Power Systems Programme: IEA PVPS Task 13, Subtask 3: Report IEA-PVPS T13-09: 2017, International Energy Agency.
16. Köntges, M., Kurtz, S., Packard, C.E., Jahn, U., Berger, K.A., Kato, K., and Miller, D. (2014). Review of Failures of Photovoltaic Modules, IEA PVPS.
17. Verifying defective PV-modules by IR-imaging and controlling with module optimizers10.1002/pip.2985 ↗
18. The reliability of bypass diodes in PV modules10.1117/12.2026782 ↗
19. Shin, W.G., Ko, S.W., Song, H.J., Ju, Y.C., Hwang, H.M., and Kang, G.H. (2018). Origin of bypass diode fault in c-Si photovoltaic modules: Current under high surrounding temperature. Energies, 11.10.3390/en11092416 ↗
20. Analysis on thermal & electrical characteristics variation of PV module with damaged bypass diodes10.7836/kses.2015.35.4.067 ↗
21. The characteristics of PV module under partial shading condition and with a failure of bypass diode with short10.7836/kses.2016.36.4.041 ↗
22. Electrical and thermal characteristics of photovoltaic modules under partial shading and with a damaged bypass diode10.1016/j.energy.2017.04.030 ↗