Show source-provided references
1. Instrumental motion analysis: From the research laboratory to the rehabilitation clinic
2. A Framework for Movement Analysis of Tasks: Recommendations From the Academy of Neurologic Physical Therapy’s Movement System Task Force
10.1093/ptj/pzab154 ↗5. Dal Farra, F., Arippa, F., Carta, G., Segreto, M., Porcu, E., and Monticone, M. (2022). Sport and non-specific low back pain in athletes: A scoping review. BMC Sports Sci. Med. Rehabil., 14.
10.1186/s13102-022-00609-9 ↗6. Influence of hamstring tightness in pelvic, lumbar and trunk range of motion in low back pain and asymptomatic volunteers during forward bending
10.4184/asj.2015.9.4.535 ↗7. Effects of exercise on balance in patients with non-specific low back pain: A systematic review and meta-analysis
8. VanDijk, M., Smorenburg, N., Visser, B., Heerkens, Y.F., and Der Sanden, M.W.G.N.-V. (2017). How clinicians analyze movement quality in patients with non-specific low back pain: A cross-sectional survey study with Dutch allied health care professionals. BMC Musculoskelet. Disord., 18.
10.1186/s12891-017-1649-3 ↗9. Schlager, A., Ahlqvist, K., Rasmussen-Barr, E., Bjelland, E.K., Pingel, R., Olsson, C., Nilsson-Wikmar, L., and Kristiansson, P. (2018). Inter- and intra-rater reliability for measurement of range of motion in joints included in three hypermobility assessment methods. BMC Musculoskelet. Disord., 19.
10.1186/s12891-018-2290-5 ↗10. Cano-de-la-Cuerda, R., Vela, L., Moreno-Verdú, M., Ferreira-Sánchez, M.d.R., Macías-Macías, Y., and Miangolarra-Page, J.C. (2020). Trunk range of motion is related to axial rigidity, functional mobility and quality of life in parkinson’s disease: An exploratory study. Sensors, 20.
10.3390/s20092482 ↗11. Shamsi, M., Mirzaei, M., and Khabiri, S. (2019). Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle. BMC Sports Sci. Med. Rehabil., 11.
10.1186/s13102-019-0116-x ↗12. Test-retest reliability of an active range of motion test for the shoulder and hip joints by unskilled examiners using a manual goniometer
10.1589/jpts.28.722 ↗14. Alarcón-Aldana, A.C., Callejas-Cuervo, M., and Bó, A.P.L. (2020). Upper limb physical rehabilitation using serious videogames and motion capture systems: A systematic review. Sensors, 20.
10.3390/s20215989 ↗15. Moro, M., Marchesi, G., Hesse, F., Odone, F., and Casadio, M. (2022). Markerless vs. marker-based gait analysis: A proof of concept study. Sensors, 22.
10.3390/s22052011 ↗16. Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L.J., and Roy, J. (2019). Validity and reliability of wearable sensors for joint angle estimation: A systematic review. Sensors, 19.
10.3390/s19071555 ↗17. The use of wearable inertial motion sensors in human lower limb biomechanics studies: A systematic review
10.3390/s101211556 ↗18. Cerfoglio, S., Capodaglio, P., Rossi, P., Conforti, I., D’Angeli, V., Milani, E., Galli, M., and Cimolin, V. (2023). Evaluation of upper body and lower limbs kinematics through an imu-based medical system: A comparative study with the optoelectronic system. Sensors, 23.
10.3390/s23136156 ↗19. Three dimensional gait analysis using wearable acceleration and gyro sensors based on quaternion calculations
10.3390/s130709321 ↗20. Li, H., Khoo, S., and Yap, H.J. (2020). Differences in motion accuracy of baduanjin between novice and senior students on inertial sensor measurement systems. Sensors, 20.
10.3390/s20216258 ↗21. Manupibul, U., Tanthuwapathom, R., Jarumethitanont, W., Kaimuk, P., Limroongreungrat, W., and Charoensuk, W. (2023). Integration of force and imu sensors for developing low-cost portable gait measurement system in lower extremities. Sci. Rep., 13.
10.1038/s41598-023-37761-2 ↗23. Zhang, H., Tao, Y., Shi, K., Li, J., Shi, J., Xu, S., and Guo, Y. (2025). Multi-Object Recognition and Motion Detection Based on Flexible Pressure Sensor Array and Deep Learning. Appl. Sci., 15.
10.3390/app15063302 ↗24. Non-hand-worn, load-free VR hand rehabilitation system assisted by deep learning based on ionic hydrogel
10.26599/NR.2025.94907301 ↗25. 5G NB-IoT System Integrated with High-Performance Fiber Sensor Inspired by Cirrus and Spider Structures
26. Validity of inertial measurement unit (imu sensor) for measurement of cervical spine motion, compared with eight optoelectronic 3d cameras under spinal immobilization devices
10.2147/MDER.S475166 ↗27. Ali, F., Hogen, C.A., Miller, E.J., and Kaufman, K.R. (2024). Validation of Pelvis and Trunk Range of Motion as Assessed Using Inertial Measurement Units. Bioengineering, 11.
10.3390/bioengineering11070659 ↗28. Parrington, L., Jehu, D.A., Fino, P.C., Pearson, S., El-Gohary, M., and King, L.A. (2018). Validation of an inertial sensor algorithm to quantify head and trunk movement in healthy young adults and individuals with mild traumatic brain injury. Sensors, 18.
10.3390/s18124501 ↗29. Abdollahi, M., Ashouri, S., Abedi, M., Azadeh-Fard, N., Parnianpour, M., Khalaf, K., and Rashedi, E. (2020). Using a motion sensor to categorize nonspecific low back pain patients: A machine learning approach. Sensors, 20.
10.3390/s20123600 ↗32. Application of the joint coordinate system to three-dimensional joint attitude and movement representation: A standardization proposal
10.1115/1.2895496 ↗35. Zaki, R.A., Bulgiba, A., Ismail, R., and Ismail, N.A. (2012). Statistical methods used to test for agreement of medical instruments measuring continuous variables in method comparison studies: A systematic review. PLoS ONE, 7.
10.1371/journal.pone.0037908 ↗36. Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J. (2018). Inertial measurement units for clinical movement analysis: Reliability and concurrent validity. Sensors, 18.
10.3390/s18030719 ↗37. Cerfoglio, S., Lopomo, N.F., Capodaglio, P., Scalona, E., Monfrini, R., Verme, F., Galli, M., and Cimolin, V. (2023). Assessment of an IMU-Based Experimental Set-Up for Upper Limb Motion in Obese Subjects. Sensors, 23.
10.3390/s23229264 ↗38. 3D trunk orientation measured using inertial measurement units during anatomical and dynamic sports motions
10.1111/sms.13851 ↗39. Lee, R., Akhundov, R., James, C., Edwards, S., and Snodgrass, S.J. (2023). Variations in concurrent validity of two independent inertial measurement units compared to gold standard for upper body posture during computerised device use. Sensors, 23.
10.3390/s23156761 ↗40. Khobkhun, F., Hollands, M.A., Richards, J., and Ajjimaporn, A. (2020). Can we accurately measure axial segment coordination during turning using inertial measurement units (imus)?. Sensors, 20.
10.3390/s20092518 ↗41. Suvorkin, V., Garcia-Fernandez, M., González-Casado, G., Li, M., and Rovira-Garcia, A. (2024). Assessment of noise of mems imu sensors of different grades for gnss/imu navigation. Sensors, 24.
10.3390/s24061953 ↗43. Lebleu, J., Gosseye, T., Detrembleur, C., Mahaudens, P., Cartiaux, O., and Penta, M. (2020). Lower limb kinematics using inertial sensors during locomotion: Accuracy and reproducibility of joint angle calculations with different sensor-to-segment calibrations. Sensors, 20.
10.3390/s20030715 ↗44. Fang, Z., Woodford, S.C., Senanayake, D., and Ackland, D.C. (2023). Conversion of upper-limb inertial measurement unit data to joint angles: A systematic review. Sensors, 23.
10.3390/s23146535 ↗45. How angular velocity features and different gyroscope noise types interact and determine orientation estimation accuracy
10.3390/s150923983 ↗46. Almassri, A.M.M., Shirasawa, N., Purev, A., Uehara, K., Oshiumi, W., Mishima, S., and Wagatsuma, H. (2022). Artificial neural network approach to guarantee the positioning accuracy of moving robots by using the integration of imu/uwb with motion capture system data fusion. Sensors, 22.
10.3390/s22155737 ↗47. Enabling precision rehabilitation interventions using wearable sensors and machine learning to track motor recovery
10.1038/s41746-020-00328-w ↗48. Park, S., and Yoon, S. (2021). Validity evaluation of an inertial measurement unit (imu) in gait analysis using statistical parametric mapping (spm). Sensors, 21.
10.3390/s21113667 ↗49. Jiménez-Olmedo, J.M., Pueo, B., Mossi, J.M., and Villalón-Gasch, L. (2023). Concurrent validity of the inertial measurement unit vmaxpro in vertical jump estimation. Appl. Sci., 13.
10.3390/app13020959 ↗50. Komaris, D., Tarfali, G., O’Flynn, B., and Tedesco, S. (2022). Unsupervised imu-based evaluation of at-home exercise programmes: A feasibility study. BMC Sports Sci. Med. Rehabil., 14.
10.1186/s13102-022-00417-1 ↗51. Predicting and monitoring upper-limb rehabilitation outcomes using clinical and wearable sensor data in brain injury survivors
10.1109/TBME.2020.3027853 ↗52. Is dynamic balance impaired in people with non-specific low back pain when compared to healthy people? A systematic review
53. Hu, Q., Liu, L., Mei, F., and Yang, C. (2021). Joint constraints based dynamic calibration of imu position on lower limbs in imu-mocap. Sensors, 21.
10.3390/s21217161 ↗54. Tramontano, M., Orejel Bustos, A.S., Montemurro, R., Vasta, S., Marangon, G., Belluscio, V., Morone, G., Modugno, N., Buzzi, M.G., and Formisano, R. (2024). Dynamic Stability, Symmetry, and Smoothness of Gait in People with Neurological Health Conditions. Sensors, 24.
10.3390/s24082451 ↗55. Discriminative ability, responsiveness, and interpretability of smoothness index of gait in people with multiple sclerosis
10.33393/aop.2025.3289 ↗