journal article·2022-12

Modelling the resonant frequency associated with the spatio-temporal evolution of the bone-dental implant interface

Sapir Gershov, Jing Xie, Furqan A. Shah, Keren Shemtov-Yona, Daniel Rittel

Acta Biomaterialia· Volume 154
Publisher page

Abstract

Dental implant stability is greatly affected by the mechanical properties of the bone-implant interface (BII), and it is key to long-term successful osseointegration. Implant stability is often evaluated using the Resonant Frequency Analysis (RFA) method, and also by the quality of this interface, namely the bone-implant contact (BIC). True to this day, there is a scarcity of models tying BIC, RFA and a spatially and mechanically evolving BII. In this paper, based on the contact/distance osteogenesis concept, a novel numerical spatio-temporal model of the implant, surrounding bone and evolving interface, was developed to assess the evolution of the interfacial stresses on the one hand and the corresponding resonant frequencies on the other. We postulate that, since the BIC percentage reaches saturation over a very short time, long before densification of the interface, it becomes irrelevant as to load transmission between the implant and the bone due to the existence of an open gap. Gap closure is the factor that provides continuity between the implant and the surrounding bone. The results of the calculated RFA evolution match and provide an explanation for the multiple clinical observations of a sharp initial decline in RFA, followed by a gradual increase and plateau formation. STATEMENT OF SIGNIFICANCE: A novel three-dimensional numerical model of an evolving bone-dental implant interface (BII) is presented. The spatio-temporal evolution of the bone-implant contact (BIC) and the BII, based on contact/distance (CO/DO) osteogenesis, is modeled. A central outcome is that, until BII maturation into a solid continuous bone (no open gap between CO-DO fronts), the bone-implant load transfer is hampered, irrespective of the BIC. The resonant frequencies' evolution of the jawbone-BII-implant is calculated to reproduce the well-established implant stability analysis based on the Resonant Frequency Analysis. The results resemble those reported clinically, and here too, the determinant transition occurs only after interfacial gap closure. Those results should motivate clinicians to re-consider structural continuity of the BII rather than the BIC only.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (61)

Show source-provided references
1. Dental implant design and its relationship to long-term implant success10.1097/01.ID.0000091140.76130.A1 ↗
2. Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man10.3109/17453678108991776 ↗
3. Current trends to measure implant stability10.4103/0972-4052.176539 ↗
4. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants10.1302/0301-620X.75B2.8444949 ↗
5. Basic and applied bone biology
6. Three-dimensional dynamic bone histomorphometry10.1002/jbmr.553 ↗
7. Biomechanical behaviours of the bone-implant interface: a review10.1098/rsif.2019.0259 ↗
8. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants10.1034/j.1600-0501.2003.00937.x ↗
9. In vivo mechanical characterization of the distraction callus during bone consolidation10.1007/s10439-015-1330-7 ↗
10. Model of the distraction callus tissue behavior during bone transport based in experiments in vivo10.1016/j.jmbbm.2016.04.016 ↗
11. A histological and histomorphometrical evaluation of retrieved human implants with a wettable, highly hydrophilic, hierarchically microstructured surface: a retrospective analysis of 14 implants10.1097/ID.0b013e3182828114 ↗
12. Bone formation around immediately loaded and submerged dental implants with a modified sandblasted and acid-etched surface after 4 and 8 weeks: a human histologic and histomorphometric analysis
13. Resonance frequency measurements of implant stability in vivo
14. Resonant frequency analysis of dental implants10.1016/j.medengphy.2019.02.008 ↗
15. A comparative study of two noninvasive techniques to evaluate implant stability: periotest and osstell mentor10.1016/j.tripleo.2008.08.026 ↗
16. Implant design and intraosseous stability of immediately placed implants: a human cadaver study10.1111/j.1600-0501.2004.01099.x ↗
17. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications10.1111/j.1600-0757.2008.00267.x ↗
18. The clinical significance of implant stability quotient (ISQ) measurements: a literature review10.1016/j.jobcr.2020.07.004 ↗
19. Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation10.1111/j.1600-0501.2007.01336.x ↗
20. Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans10.1111/j.1708-8208.2006.00022.x ↗
21. Implant primary stability determined by resonance frequency analysis: correlation with insertion torque, histologic bone volume, and torsional stability at 6 weeks10.1097/ID.0b013e31826918f1 ↗
22. Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible10.1111/j.1708-8208.2003.tb00020.x ↗
23. Modal analysis for implant stability assessment: sensitivity of this methodology for different implant designs10.1016/j.dental.2018.05.016 ↗
24. Analysis of bone-implant interaction phenomena by using a numerical approach10.1111/j.1600-0501.2005.01162.x ↗
25. Understanding and controlling the bone-implant interface10.1016/S0142-9612(99)00160-X ↗
26. A stochastic micro to macro mechanical model for the evolution of bone-implant interface stiffness10.1016/j.actbio.2021.06.019 ↗
27. Bone bonding at natural and biomaterial surfaces10.1016/j.biomaterials.2007.07.049 ↗
28. Bone-implant contact and bone quality: evaluation of expected and actual bone contact on machined and osseotite implant surfaces
29. Influence of implant surface topography on early osseointegration: a histological study in human jaws10.1002/jbm.b.30608 ↗
30. Effect of smoking on early bone healing around oxidized surfaces: a prospective, controlled study in human jaws10.1902/jop.2010.090493 ↗
31. Impact of smoking on human bone apposition at different dental implant surfaces: a histologic study in type IV bone10.1563/AAID-JOI-D-09-00018 ↗
32. Early human bone response to laser metal sintering surface topography: a histologic report10.1563/AAID-JOI-D-09-00003 ↗
33. Bone healing at functionally loaded and unloaded screw-shaped implants supporting single crowns: a histomorphometric study in humans10.11607/jomi.5928 ↗
34. Preferred collagen fiber orientation human peri-implant bone after a short- and long-term loading period: a case report10.1563/285.1 ↗
35. Bone response to submerged, unloaded implants inserted in poor bone sites: a histological and histomorphometrical study of 8 titanium implants retrieved from man10.1563/1548-1336(2005)31[225:BRTSUI]2.0.CO;2 ↗
36. Immediate loading of osseotite implants: a case report and histologic analysis after 4 months of occlusal loading
37. Bone contact around acid-etched implants: a histological and histomorphometrical evaluation of two human-retrieved implants10.1563/1548-1336(2003)029<0013:BCAAIA>2.3.CO;2 ↗
38. Histologic evaluation of a human immediately loaded titanium implant with a porous anodized surface10.1111/j.1708-8208.2002.tb00160.x ↗
39. Early bone formation around immediately restored implants with and without occlusal contact: a human histologic and histomorphometric evaluation. Case report
40. Periimplant bone in immediately loaded titanium implants: histologic and histomorphometric evaluation in human. A report of two cases10.1111/j.1708-8208.2003.tb00199.x ↗
41. Early bone formation around immediately loaded transitional implants inserted in the human posterior maxilla: the effects of fixture design and surface10.1155/2017/4152506 ↗
42. Histologic evaluation of a provisional implant retrieved from man 7 months after placement in a sinus augmented with calcium sulphate: a case report10.1563/0.808.1 ↗
43. Bone response to dental implants after a 3- to 10-year loading period: a histologic and histomorphometric report of four cases10.11607/prd.1257 ↗
44. Bone-to-implant contact around immediately loaded direct laser metal-forming transitional implants in human posterior maxilla10.1902/jop.2012.120126 ↗
45. The effect of cigarette smoking on early osseointegration of dental implants: a prospective controlled study10.1111/clr.12705 ↗
46. Early bone formation around immediately loaded implants with nanostructured calcium-incorporated and machined surface: a randomized, controlled histologic and histomorphometric study in the human posterior maxilla10.1007/s00784-017-2061-y ↗
47. Human peri-implant bone response to turned and oxidized titanium implants inserted and retrieved after 2 months10.1097/ID.0b013e3180de4d64 ↗
48. Early bone response to dual acid-etched and machined dental implants placed in the posterior maxilla: a histologic and histomorphometric human study10.1097/ID.0000000000000511 ↗
49. Randomized, controlled histologic and histomorphometric evaluation of implants with nanometer-scale calcium phosphate added to the dual acid-etched surface in the human posterior maxilla10.1902/jop.2007.060297 ↗
50. MIS SEVEN - Internal hexagon implant system | MIS dental implants, (n.d.). https://www.mis-implants.com/products/implant-systems/seven (accessed June 22, 2022 ).
51. Dynamic modelling and simulation of dental implant insertion process-A finite element study10.1016/j.finel.2011.03.005 ↗
52. ABAQUS, Abaqus 6.14 documentation, abaqus 6.14 anal. User's Guid. (2014) 14. http://130.149.89.49:2080/v6.14/ (accessed July 17, 2022).
53. Lang · 2021
54. Stability measurements of one-stage Brånemark implants during healing in mandibles10.1016/S0901-5027(99)80156-8 ↗
55. Resonance frequency analysis of one- stage dental implant stability during the osseointegration period10.1902/jop.2005.76.7.1066 ↗
56. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants10.1111/j.1600-0501.2004.01036.x ↗
57. Ninety percent success in palatal implants loaded 1 week after placement: a clinical evaluation by resonance frequency analysis10.1111/j.1600-0501.2005.01223.x ↗
58. Dental implant stability and its measurements to improve osseointegration at the bone-implant interface: a review10.1016/j.matpr.2020.08.243 ↗
59. patient selection
60. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement10.1016/S0278-2391(99)90437-8 ↗
61. Quantitative assessment of the jawbone quality classification: a meta-analysis study10.1371/journal.pone.0253283 ↗