journal article·2010-02Open access

Bioactive polymer grafting onto titanium alloy surfaces

A. Michiardi, G. Hélary, P.-C.T. Nguyen, L.J. Gamble, F. Anagnostou, D.G. Castner, V. Migonney

Acta Biomaterialia· Volume 6· Issue 2

Abstract

Bioactive polymers bearing sulfonate (styrene sodium sulfonate, NaSS) and carboxylate (methylacrylic acid, MA) groups were grafted onto Ti6Al4V alloy surfaces by a two-step procedure. The Ti alloy surfaces were first chemically oxidized in a piranha solution and then directly subjected to radical polymerization at 70 degrees C in the absence of oxygen. The grafted surfaces were characterized by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS) and the toluidine blue colorimetric method. Toluidine blue results showed 1-5microgcm(-2) of polymer was grafted onto the oxidized Ti surfaces. Grafting resulted in a decrease in the XPS Ti and O signals from the underlying Ti substrate and a corresponding increase in the XPS C and S signals from the polymer layer. The ToF-SIMS intensities of the S(-) and SO(-) ions correlated linearly with the XPS atomic percent S concentrations and the ToF-SIMS intensity of the TiO(3)H(2)(-) ion correlated linearly with the XPS atomic per cent Ti concentration. Thus, the ToF-SIMS S(-), SO(-) and TiO(3)H(2)(-) intensities can be used to quantify the composition and amount of grafted polymer. ToF-SIMS also detected ions that were more characteristic of the polymer molecular structure (C(6)H(4)SO(3)(-) and C(8)H(7)SO(3)(-) from NaSS, C(4)H(5)O(2)(-) from MA), but the intensity of these peaks depended on the polymer thickness and composition. An in vitro cell culture test was carried out with human osteoblast-like cells to assess the influence of the grafted polymers on cell response. Cell adhesion after 30min of incubation showed significant differences between the grafted and ungrafted surfaces. The NaSS grafted surfaces showed the highest degree of cell adhesion while the MA-NaSS grafted surfaces showed the lowest degree of cell adhesion. After 4 weeks in vivo in rabbit femoral bones, bone was observed to be in direct contact with all implants. The percentage of mineralized tissue around the implants was similar for NaSS grafted and non-grafted implants (59% and 57%). The MA-NaSS grafted implant exhibited a lower amount of mineralized tissue (47%).
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Ratner BD, Hoffman AS, Shoen FJ, Lemons JE, editors. Biomaterials science: an introduction to materials in medicine. 2nd ed., 2004; Brunski JB. Part I: Materials science and engineering, Chapter 2: Classes of materials used in medicine. p. 138–52; Hallab NJ, Jacobs JJ, Katz JL. Part II: Biology, biochemistry and medicine, Chapter 7: Application of materials in medicine, biology and artificial organs. p. 527–55.
2. Titanium and titanium alloys, biomaterials of preference
3. Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces10.1016/j.actbio.2008.07.032 ↗
4. Titanium alloys in total joint replacement – a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
5. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
6. Plasma sprayed coatings of hydroxylapatite10.1002/jbm.820211203 ↗
7. The influence of titania/hydroxyapatite composite coatings on in vitro osteoblasts behaviour10.1016/S0142-9612(00)00269-6 ↗
8. In situ laser coating of calcium phosphate on TC4 surface for enhancing bioactivity10.1016/S1006-706X(07)60047-8 ↗
9. Exploration of preparation for bioactive calcium phosphate coating by using high frequency induction heat gradient technique of Ti6A14V
10. Comparative push-out test of dense HA implants and HA-coated implants: findings in a canine study10.1002/(SICI)1097-4636(19980305)39:3<364::AID-JBM4>3.0.CO;2-H ↗
11. Differences in microstructural characteristics of dense HA and HA coating10.1002/(SICI)1097-4636(199808)41:2<296::AID-JBM15>3.0.CO;2-J ↗
12. Physics of hydroxyapatite plasma coatings on TiNi shape memory materials10.1016/S0921-5093(97)00265-7 ↗
13. Design of bioactive bone substitutes based on biomineralization process10.1016/j.msec.2005.01.002 ↗
14. Preparation of bioactive Ti6Al4V surfaces by a simple method10.1016/S0142-9612(97)00232-9 ↗
15. Ion implantation: surface treatment for improving the bone integration of titanium and Ti6Al(4)V dental implants10.1034/j.1600-0501.2003.140108.x ↗
16. Wettability modification and the subsequent manipulation of protein adsorption on a Ti6Al4V alloy by means of CO2 laser surface treatment10.1007/s10856-006-0002-4 ↗
17. On the correlation between Nd:YAG laser-induced wettability characteristics modification and osteoblast cell bioactivity on a titanium alloy10.1016/j.surfcoat.2005.07.107 ↗
18. Thermal oxidation enhances early interactions between human osteoblasts and alumina blasted Ti6Al4V alloy10.1002/jbm.a.30994 ↗
19. Osteoblast response to thermally oxidized Ti6Al4V alloy10.1002/jbm.a.30264 ↗
20. Research and development on surface bioactivity methods of titanium and its alloys
21. Grafting of bioactive polymers onto titanium surfaces and human osteoblasts response10.1016/j.rbmret.2007.10.001 ↗
22. A new approach to graft bioactive polymer on titanium implants: improvement of MG 63 cell differentiation onto this coating10.1016/j.actbio.2008.07.037 ↗
23. Comparative study of silanisation reactions for the biofunctionalisation of Ti-surfaces10.1016/j.susc.2006.04.021 ↗
24. Surface modification of titanium with phosphonic acid to improve bone bonding: characterization by XPS and ToF-SIMS10.1021/la010908i ↗
25. Osteoblast culture on polished titanium disks modified with phosphonic acids10.1002/jbm.10205 ↗
26. Surface modification of silicone intraocular implants to inhibit cell proliferation10.1021/bm058010l ↗
27. Bioactive poly(ethylene terephthalate) fibers and fabrics: grafting, chemical characterization, and biological assessment10.1021/bm070344i ↗
28. Biomaterials inhibiting bacterial adhesion and proliferation: a challenge to prevent infection of prosthetic materials10.1016/j.rbmret.2005.04.012 ↗
29. Goudiaby Z. Modulation of osteoblastic differentiation by poly(methyl methacrylate) based bioactive polymers. Thesis. University of Paris 13; 2004.
30. Introduction of functional groups onto the surface of polyethylene for protein immobilization10.1016/0142-9612(93)90003-K ↗
31. Radical graft polymerization of styrene sulfonate on poly(ethylene terephthalate) films for ACL applications: “grafting from” and chemical characterization10.1021/bm050694+ ↗
32. Titanium–hydrogen peroxide interaction: model studies of the influence of the inflammatory response on titanium implants10.1016/0142-9612(89)90019-7 ↗
33. Platelet adhesion on titanium oxide gels: effect of surface oxidation10.1016/j.biomaterials.2003.10.070 ↗
34. Synthesis of polypropylene fabric with sulfonate group10.1016/j.radphyschem.2007.09.012 ↗
35. Static secondary ion mass spectrometry and X-ray photoelectron spectroscopy of deuterium- and methyl-substituted polystyrene10.1366/0003702914337588 ↗
36. Analysis of polymer surfaces by SIMS. 2:fingerprint spectra from simple polymer films10.1002/sia.740040405 ↗
37. Analysis of polymer surfaces by SIMS. 12: on the fragmentation of acrylic and methacrylic homopolymers and the interpretation of their positive and negative ion spectra10.1002/sia.740110405 ↗
38. Surface chemical characterization using XPS and ToF-SIMS of latex particles prepared by the emulsion copolymerization of methacrylic acid and styrene10.1021/la960169j ↗