Stable room-temperature thallium bromide semiconductor radiation detectors
Source abstract
Abstract
Thallium bromide (TlBr) is a highly efficient ionic semiconductor with excellent radiation detection properties. However, at room temperature, TlBr devices polarize under an applied electric field. This phenomenon not only degrades the charge collection efficiency of the detectors but also promotes chemical reaction of the metal electrodes with bromine, resulting in an unstable electric field and premature failure of the device. This drawback has been crippling the TlBr semiconductor radiation detector technology over the past few decades. In this exhaustive study, this polarization phenomenon has been counteracted using innovative bias polarity switching schemes. Here the highly mobile Br− species, with an estimated electro-diffusion velocity of 10−8 cm/s, face opposing electro-migration forces during every polarity switch. This minimizes the device polarization and availability of Br− ions near the metal electrode. Our results indicate that it is possible to achieve longer device lifetimes spanning more than 17 000 h (five years of 8 × 7 operation) for planar and pixelated radiation detectors using this technique. On the other hand, at constant bias, 2500 h is the longest reported lifetime with most devices less than 1000 h. After testing several biasing switching schemes, it is concluded that the critical bias switching frequency at an applied bias of 1000 V/cm is about 17 μHz. Using this groundbreaking result, it will now be possible to deploy this highly efficient room temperature semiconductor material for field applications in homeland security, medical imaging, and physics research.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Semiconductor Detectors and Materials · Radiation Detection and Scintillator Technologies · Luminescence Properties of Advanced Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
CapeSym, Inc. 1 , 6 Huron Drive, Natick, Massachusetts 01760, USA
Massachusetts Institute of Technology 2 , Cambridge, Massachusetts 02139, USA
Funding
U.S. Department of Homeland Security
References (14)
Show source-provided references
1. W. H. McMaster , N. K. D.Grande, J. H.Malett, and J. H.Hubbel, Compilation of X-ray Cross Sections, Lawrence Radiation Laboratory Report UCRL-50174- SEC2-R1, 1969.
2. Nucl. Instrum. Methods Phys. Res. A · 2014 · 747 · 710.1016/j.nima.2014.02.020 ↗
3. IEEE Trans. Nucl. Sci. · 2009 · 56 · 185910.1109/tns.2009.2013349 ↗
4. Nucl. Instrum. Methods Phys. Res. A · 2015 · 784 · 3710.1016/j.nima.2015.01.021 ↗
5. IEEE Trans. Nucl. Sci. · 2015 · 62 · 124410.1109/tns.2015.2427779 ↗
6. IEEE Trans. Nucl. Sci. · 2009 · 56 · 181710.1109/tns.2009.2024678 ↗
7. J. Appl. Phys. · 2010 · 108 · 06450710.1063/1.3481433 ↗
8. IEEE Trans. Nucl. Sci. · 1980 · 27 · 26610.1109/tns.1980.4330837 ↗
9. IEEE Trans. Nucl. Sci. · 2015 · 62 · 43710.1109/tns.2015.2400396 ↗
10. IEEE Trans. Nucl. Sci. · 2013 · 60 · 123110.1109/tns.2013.2252363 ↗
11. Nucl. Instrum. Methods Phys. Res. A · 2010 · 623 · 102410.1016/j.nima.2010.08.024 ↗
12. J. Cryst. Growth · 2016 · 452 · 4910.1016/j.jcrysgro.2016.01.009 ↗
13. IEEE Trans. Nucl. Sci. · 2015 · 62 · 178510.1109/tns.2015.2448420 ↗
14. Phys. Rev. B · 2013 · 87 · 08120210.1103/physrevb.87.081202 ↗