Application of magnetic field detection for non-contact measurement of leakage current in low-voltage distribution network
Source abstract
Abstract
Traditional methods for measuring leakage current typically require direct contact with the circuit, a practice that increases operational safety risks and makes it difficult to detect weak leakage currents, thus rendering leakage current measurement particularly challenging. Therefore, a non-contact leakage current measurement method based on magnetic field detection for low-voltage distribution network lines is proposed. A monitoring framework for leakage current in low-voltage distribution network lines is constructed. In this framework, the transducer module employs a non-contact magnetic modulation DC leakage current transformer to detect the magnetic field around the low-voltage distribution line, capturing the magnetic field variations caused by weak leakage currents to obtain the voltage waveform offset across a sampling resistor, thereby achieving accurate leakage current acquisition. Subsequently, an adaptive filter is utilized to suppress noise and interference signals in the leakage current signal. The filtered leakage current signal is transmitted to an STM32 microcontroller, which converts the signal into a leakage current value and determines the leakage location by injecting a specific frequency signal at the neutral point of the low-voltage distribution network line. Leakage information is displayed on an LED bar graph, and an alarm is triggered when the leakage exceeds the threshold. Simultaneously, leakage data are uploaded in real time to a host computer via a Bluetooth module, facilitating monitoring by the administrator. This method integrates magnetic modulation detection, adaptive filtering, and neutral-point frequency injection-based localization, overcoming the limitations of traditional contact measurement methods—such as high safety risks—as well as the difficulties in detecting weak leakage currents and accurately locating faults in non-contact techniques. It promotes the transformation of leakage current measurement technology from manual operation toward intelligent, safe, and precise solutions. By innovatively combining a magnetic modulation transformer with an adaptive filtering algorithm and incorporating a neutral-point frequency injection localization scheme, high-precision measurement and localization can be achieved without physical contact with the circuit, addressing the core challenges of leakage current measurement in complex low-voltage substation environments. Experimental results show that the leakage current measurement accuracy of this method reaches ±1 mA, with a minimum detectable leakage current of 1 mA. The signal clutter suppression rate reaches 92%, and the leakage fault location error is controlled within 0.2 m. When the threshold is exceeded, an alarm is triggered within 0.5 s. This approach significantly reduces manual testing costs and electric shock risks, minimizes equipment damage and safety accidents caused by leakage currents, and provides reliable technical support for the safe and stable operation of distribution network electrical systems.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magnetic Field Sensors Techniques · Magneto-Optical Properties and Applications · High voltage insulation and dielectric phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Electric Energy Metrology Branch of Inner Mongolia Electric Power Group Co., Ltd. , Huhohot, Inner Mongolia 010000,
References (20)
Show source-provided references
1. Early recovery and section reduction measures in the event of a power outage caused by electric leakage or overcurrent in indoor wiring10.1541/ieejpes.143.51 ↗
2. Characterization of gallium oxide with a novel non-contact electrical metrology, CnCV, for wide bandgap semiconductors10.1149/10806.0057ecst ↗
3. Positive and negative leakage current detection of DC lines applying the proposed signal conversion algorithm10.1007/s42835-023-01728-0 ↗
4. A non-contact current traveling wave fault location method for multi-terminal overhead power lines based on adaptive mathematical morphology10.1007/s00202-024-02495-5 ↗
5. Using power line communication for fault detection and localization in star-shaped network10.1016/j.ifacol.2022.07.182 ↗
6. Voltage–current locus-based stator winding inter-turn fault detection in induction motors10.1002/cta.3561 ↗
7. Development of an electromagnetic energy harvesting system based on a current transformer for use in industrial electric motors10.1109/TLA.2023.10251803 ↗
8. Design of a current-transformer based inductive coupler for power-line communications10.1109/TPWRD.2022.3227238 ↗
9. Detection and control of the effective magnetic field in a Ca-doped Bi2Se3 topological insulator10.1002/aelm.202101075 ↗
10. On the reconstruction of the attenuation function of a return-Stroke current from the Fourier transform of finite-duration measurements10.1016/j.ijepes.2022.108186 ↗
11. Calculation of current distribution in parallel-connected transformer winding sections in the case of asymmetric magnetic field during short-circuit test10.1016/j.epsr.2022.108141 ↗
12. Simulation of improved diffusion subband adaptive filtering algorithms10.3969/j.issn.1006-9348.2022.02.059 ↗
13. Shear complex modulus imaging utilizing frequency combination in the least mean square/algebraic Helmholtz inversion10.1007/s11042-023-17061-7 ↗
14. Proposal of prediction method of leakage current generation of polymeric insulators for distribution lines using neural network10.1541/ieejpes.143.282 ↗
15. Structural, dielectric, electrical, and leakage current properties of SrWO4 for electronic devices10.1007/s43207-024-00438-1 ↗
16. Silicon ultrafast recovery diode with leakage current reduced via the combined lifetime process of gold diffusion and electron-beam irradiation10.1088/1361-6641/ad14ec ↗
17. Improved proportionate constrained normalized least mean square for adaptive beamforming10.1007/s00034-023-02459-3 ↗
18. Reduced leakage current and enhanced energy storage performance of BZNT/BTO multilayer structures: Implications in electronic devices10.1016/j.apsusc.2024.159358 ↗
19. Structure, optical, charge transport mechanism, dielectric properties and leakage current analysis of Sm2MgMnO6 double perovskite10.1016/j.ijhydene.2023.09.034 ↗
20. Reduced peripheral leakage current in pin photodetectors of Ge on n+-Si by P+ implantation to compensate surface holes10.1587/transele.2023FUS0001 ↗