journal article·2026-03-01Open access

A way to evaluate particles inducing soft errors in relay protection device: From Geant4 to fault injection platform

Hao Yu, Hualiang Zhou, Zhiyang Zou, Zhantao Su, Zheng Xu, Weitao Yang, Chaohui He

AIP Advances· Volume 16· Issue 3

Abstract

Relay protection devices that use advanced integrated circuits are increasingly exposed to soft errors caused by atmospheric neutrons and α particles. This work presents a fault injection method that uses radiation transport simulations to evaluate the soft error response of a commercial line protection device. Geant4 simulations of atmospheric neutrons and package α sources were used to estimate single-event upset rates and obtain the spatial distributions of single-bit and multi-bit upsets in on-chip memory. These data define the number, type, and location of bit flips injected by a host and agent software framework running on the target device without hardware modification. Tests on an NSR-3611 relay protection device showed that only about 4.7% of the total 830 injected faults lead to observable malfunctions, defined as erroneous outputs or execution interruptions. Multi-bit upsets caused by α particles are more likely to generate erroneous outputs than to stop execution. The approach provides a low-cost and repeatable method to emulate safety-relevant failure modes and guide the hardening of relay protection systems.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Effects in Electronics · Interconnection Networks and Systems · Graphite, nuclear technology, radiation studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Nuclear Science and Technology, Xi’an Jiaotong University 1 , Xi’an 710049,

NARI Group Corporation (State Grid Electric Power Research Institute) 2 , Nanjing 211106,

NARI Technology Co., Ltd. 3 , Nanjing 211106,

Funding

Science and Technology Project of NARI Technology Co., Ltd.

References (24)

Show source-provided references
1. Analysis of reliability for relay protection systems in smart substation
2. Technology and operation of electric power systems10.1007/978-1-4471-5034-3_1 ↗
3. New development in relay protection for smart grid10.1186/s41601-016-0025-x ↗
4. An intelligent protection scheme to deal with extreme fault currents in smart power systems10.1016/j.ijepes.2019.105434 ↗
5. Impact of the integration of information and communication technology on power system reliability: A review10.1109/access.2020.2970598 ↗
6. A comprehensive review on the modern power system reliability assessment10.20508/ijrer.v11i4.12480.g8326 ↗
7. Impact of atmospheric and space radiation on sensitive electronic devices
8. Contribution of thermal neutrons to soft error rate10.1109/tns.2018.2813367 ↗
9. Single-event effects ground testing and on-orbit rate prediction methods: The past, present, and future10.1109/tns.2003.813331 ↗
10. Fast neutron irradiation tests of flash memories used in space environment at the ISIS spallation neutron source10.1063/1.5017945 ↗
11. Measurement of single event effects induced by alpha particles in the Xilinx Zynq-7010 system-on-chip10.1080/00223131.2016.1262294 ↗
12. Analysis and countermeasures of single event upset soft errors in a relay protection device
13. Impacts of single event upsets on protective relays
14. Single event upsets in SEL relays
15. The evaluation method of SEU effect on relay protection devices10.1016/j.egyr.2025.04.031 ↗
16. Test method and failure rate of the single-particle effect of a relay protection device
17. Single event effect protection design of output module of relay protection device10.1088/1742-6596/2785/1/012027 ↗
18. Atmospheric neutron single event effect test on Xilinx 28 nm system-on-chip at CSNS-BL0910.1016/j.microrel.2019.05.004 ↗
19. Electron inducing soft errors in 28 nm system-on-chip10.1080/10420150.2020.1759067 ↗
20. Neutron irradiation testing and Monte Carlo simulation of a Xilinx Zynq-7000 system on chip10.3390/electronics12092057 ↗
21. GEANT4—A simulation toolkit10.1016/s0168-9002(03)01368-8 ↗
22. Measurement and simulation of terrestrial atmospheric neutron spectrum in typical regions of China10.11884/HPLPB202335.220353 ↗
23. Evaluation of single event upset on a relay protection device10.3390/electronics13010064 ↗
24. Relay protection device reliability assessment through radiation, fault injection and fault tree analysis10.3390/mi16010069 ↗