journal article·2026-01-01Open access

Nonlinear photon emission and discharge mode transitions in HVDC needle–needle electrodes: Insights from UV photon spot distribution mapping

Zhiliang Yin, Wei Ma, Xiuhai Wu, Jinwei Lv, Xiang Shen, Rui Qiu

AIP Advances· Volume 16· Issue 1

Abstract

This study proposes a methodology for the development of ultraviolet (UV) spot distribution mapping with probabilistic processing, with the objective of addressing the challenges associated with the monitoring of partial discharge (PD) in high-voltage direct current (HVDC) equipment and analyzing its mechanism. An experimental platform with adjustable needle–needle electrodes (5–25 mm gap) was established to simulate insulation defects, enabling quantitative analysis through a dedicated UV image processing framework. The research demonstrates that the transition of photon counting characteristics from bell-shaped to U-shaped distributions with increasing electrode distance is governed by the spatial reorganization of discharge regions. UV spot distribution mapping reveals that this nonlinear behavior stems from expanded UV emission zones at larger distances and constrained discharge region coalescence at smaller gaps, while spectral red-shift toward infrared wavelengths during discharge intensification further modulates photon counting patterns. A unified mathematical model was developed, incorporating both spatial and spectral evolution mechanisms. The unified model, designated as, has been shown to be effective in this regard. Spatial analysis identified characteristic discharge core zones with pronounced polarity asymmetry. The probabilistic methodology effectively discriminates between persistent discharge zones and random photon events, enabling quantitative assessment of discharge stability and evolution. The findings establish a framework correlating UV spot distribution dynamics with photon counting behavior, providing both fundamental insights into DC PD mechanisms and practical methodologies for insulation condition assessment in HVDC systems.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation · High-Voltage Power Transmission Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Extra High Voltage Converter Station Branch, State Grid Shanghai Electric Power Company 1 , Shanghai 201314,

School of Electrical Engineering and Automation, Wuhan University 2 , Wuhan 430072,

Funding

Science and Technology Program of Extra High Voltage Converter Station Branch, State Grid Shanghai Electric Power Company

References (22)

Show source-provided references
1. HVDC transmission: Technology review, market trends and future outlook10.1016/j.rser.2019.04.062 ↗
2. HVDC transmission and its potential application in remote communities: Current practice and future trend10.1109/tia.2022.3146117 ↗
3. Review and outlook of HVDC grids as backbone of transmission system10.17775/CSEEJPES.2020.04890 ↗
4. Monitoring technologies for HVDC transmission lines10.3390/en16135085 ↗
5. Metrological qualification of PD analysers for insulation diagnosis of HVDC and HVAC grids10.3390/s23146317 ↗
6. Combined characterization of free-moving particles in HVDC-GIS using UHF PD, high-speed imaging, and pulse-sequence analysis10.1109/tpwrd.2019.2909830 ↗
7. Design and implementation of ultraviolet imager for Corona discharge detection based on solar-blind AlGaN focal plane arrays
8. Influence of ambient humidity on UV imaging detection of polluted plate model discharge
9. Influencing of water droplets on Corona inception characteristics of composite insulator recorded by UV imager10.1049/iet-smt.2019.0558 ↗
10. Application of robot detection equipped with ultraviolet imaging
11. Analysis of ultraviolet imaging detection in external detection of substation equipment10.1007/s12596-022-00840-0 ↗
12. Spatial spectral characteristics of partial discharge with different electrode models10.3390/photonics10070788 ↗
13. Identification of partial discharge based on composite optical detection and transformer-based deep learning model10.1109/tps.2024.3382320 ↗
14. Accurate ultraviolet image detection of electrical equipment based on Gaussian color mapping image segmentation algorithm10.3390/app15052837 ↗
15. Automated monitoring of insulation by ultraviolet imaging employing deep learning10.1016/j.measurement.2024.116018 ↗
16. Ultraviolet imaging of external insulation discharge of electrical equipment based on diffusion model detection10.1002/tee.24267 ↗
17. Effect of surface aging on UV intensity characteristics for long-term energized conductors of HVDC transmission lines
18. Sensitivity of the electrical and UV imaging methods for Corona detection under HVDC application
19. Analysis of partial discharge disturbance during dielectric tests between VSC-HVDC valve terminals10.1049/icp.2023.0222 ↗
20. Research on ultraviolet characteristic parameters of DC-Positive polarity Corona discharge on conductors10.3390/app14083258 ↗
21. Characteristic emission spectrum analysis and discharge identification on the development process of air Corona discharge10.3964/j.issn.1000-0593(2022)09-2956-07 ↗
22. Classification of partial discharge severities of ceramic insulators based on texture analysis of UV pulses10.1049/hve2.12081 ↗