Optimizing time integration for accurate recovery of shockwave interface location in radiography
Source abstract
Abstract
We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Digital Radiography and Breast Imaging · Medical Imaging Techniques and Applications · Laser-Plasma Interactions and Diagnostics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Lawrence Livermore National Laboratory , 7000 East Ave., Livermore, California 94550,
References (20)
Show source-provided references
1. Flash x-ray radiography using imaging plates for the observation of hypervelocity objects10.1063/1.1844411 ↗
2. A flash x-ray radiography diagnostic for studing surface phenomena under shock loading10.1063/1.46171 ↗
3. Flash x-ray radiography analysis of detonation wave propagation in additive-manufactured high explosives10.1063/5.0146540 ↗
4. Investigating motion blur by imaging shock front propagation10.1063/12.0020362 ↗
5. Motion-invariant photography
6. The effect of motion blur and signal noise on image quality in low light imaging10.1007/978-3-642-02230-2 ↗
7. Temporal multiplexing radiography for dynamic x-ray imaging10.1063/1.3215939 ↗
8. A framework for optimising the radiographic technique in digital x-ray imaging10.1093/rpd/nch562 ↗
9. 1948
10. Quantifying motion blur by imaging shock front propagation with broadband and narrowband x-ray sources10.1038/s41598-024-76444-4 ↗
11. DCS-A high flux beamline for time resolved dynamic compression science–design highlights10.1063/1.4952859 ↗
12. Dynamic compression of materials: Metallization of fluid hydrogen at high pressures10.1088/0034-4885/69/5/r05 ↗
13. Ultrafast shock compression of PDMS-based polymers10.1002/polb.24589 ↗
14. C. R. Noble , A. T.Anderson, N. R.Barton, J. A.Bramwell, A.Capps, M. H.Chang, J. J.Chou, D. M.Dawson, E. R.Diana, T. A.Dunnet al., ALE3D: An Arbitrary Lagrangian-Eulerian Multi-Physics Code, Lawrence Livermore National Laboratory, Livermore, CA, 2017.10.2172/1361589 ↗
15. HADES a radiographic simulation code10.1063/1.1373801 ↗
16. 1989
17. Radiographic techniques, contrast, and noise in x-ray imaging10.2214/ajr.14.13116 ↗
18. Realizing increased sub-pixel spatial resolution in x-ray imaging using displaced multiple images10.1016/j.nima.2010.06.179 ↗
19. Improving x-ray images resolution using subpixel shifts of the detector
20. Super-resolution scanning transmission x-ray imaging using single biconcave parabolic refractive lens array10.1038/s41598-019-50869-8 ↗