journal article·2025-07-01Open access

Research on electromagnetic induction characteristics of HVTL based on improved XGboost integrated machine learning

Ye Wang, Hao Chen, Honghua Xu, Xuchao Ren, Liwei Wang, Tao Huang, Xiaoyu Li

AIP Advances· Volume 15· Issue 7

Abstract

With the expansion of transmission demand in the power system, high-voltage transmission technology has been widely applied in the field of transmission. Some high-voltage transmission lines have small spacing between circuits, especially double circuit high-voltage transmission lines on the same tower or in the same corridor. When one circuit is shut down and the other circuit is in operation, the induced voltage and current on the shutdown circuit are high, which affects the stable operation of the power system. This article first analyzes the electromagnetic induction characteristics of high-voltage transmission lines. Then, based on the actual engineering background, ATP-EMPT simulation software was applied to build a simulation model of a 500 kV double circuit transmission line on the same tower or in the same corridor, considering the effects of different line lengths, transmission currents, horizontal spacing between lines, and tower call heights on the induced voltage and current of the shutdown line. Based on this prediction, the induced voltage and current are analyzed, and then the XGboost algorithm optimized by the Guanhao Pig algorithm is used to calculate and analyze the induced voltage and current of unknown lines. The measured data and simulation results show that the prediction algorithm proposed in this paper has high accuracy, providing a certain reference basis for determining the operating parameters of transmission lines.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Machine Fault Diagnosis Techniques · Power Systems Fault Detection · Power Transformer Diagnostics and Insulation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Power Dispatching and Control Center, State Grid Jiangsu Electric Power Co., Ltd. 1 , No. 215 Shanghai Road, Nanjing, Jiangsu 210024,

500 kV Substation Operation and Maintenance Center, State Grid Nanjing Power Supply Company 2 , No. 1 Zhongyang Road, Nanjing, Jiangsu 210019,

Technology Innovation and Digitalization Department, State Grid Nanjing Power Supply Company 3 , No. 1 Zhongyang Road, Nanjing, Jiangsu 210019,

Power Dispatching and Control Center, State Grid Nanjing Power Supply Company 4 , No. 1 Zhongyang Road, Nanjing, Jiangsu 210019,

Unmanned Aerial Vehicle Inspection Technology Service Center, Jiangsu Frontier Electric Power Technology Co., Ltd. 5 , No. 58 Suyuan Avenue, Nanjing, Jiangsu 211102,

Funding

State Grid Jiangsu Electric Power

References (28)

Show source-provided references
1. Dynamic simulation of induced voltages in high voltage cable sheaths: Steady state approach10.1016/j.ijepes.2018.08.003 ↗
2. Method to measure the unbalance of the multiple-circuit transmission lines on the same tower and its applications10.1049/iet-gtd.2015.0979 ↗
3. Time-domain fault location algorithm for double-circuit transmission lines connected to large scale wind farms10.1109/access.2021.3049484 ↗
4. Analysis on phase arrangement and transposition modes for UHV DC and double-circuit EHV AC transmission line built on the same tower10.3969/j.issn.1003-6520.2012.12.005 ↗
5. Uncertainty in transmission line parameters: Estimation and impact on line current differential protection10.1109/tim.2013.2292276 ↗
6. New approach for precisely measuring the zero-sequence parameters of long-distance double-circuit transmission lines10.1109/tpwrd.2015.2489246 ↗
7. A new measurement and calculation method for phase parameter of double circuit transmission lines on the same tower10.13335/j.1000-3673.pst.2022.1311 ↗
8. Induced voltages on fence wires and pipelines by AC power transmission lines10.1109/28.287525 ↗
9. Steady-state and shock currents induced by ELF electric fields in a human body and a nearby vehicle10.1109/15.45251 ↗
10. Measurement and simulation of induced voltage and current on 110 kV crossing transmission lines under UHV AC transmission lines10.4236/epe.2017.94B069 ↗
11. Induced voltage of overhead ground wires in 50 0-kV single-circuit transmission lines10.1109/tpwrd.2013.2251371 ↗
12. Research on induced voltage and current in deenergized line of double-circuit transmission lines on the same tower
13. Research on induced current and induced voltage of 500 kV double circuit transmission line10.1016/j.egyr.2021.01.077 ↗
14. Analysis on induced voltage of 500 kV double circuit on the same tower
15. Characteristic of power-transmission-induced current and power loss on the OPGW of 750 kV transmission line system10.1016/j.epsr.2024.110130 ↗
16. Analysis of induced components in hybrid HVAC/HVDC transmission lines on the same tower for various fault conditions10.1016/j.epsr.2023.109884 ↗
17. Coupling characteristics between MMC-HVDC and AC transmission lines on the same tower and their impact on protective relaying10.1016/j.ijepes.2024.110000 ↗
18. Research on current interruption by grounding switch used in 750 kV double-circuit transmission lines
19. Analysis of electromagnetic interference on DC line from parallel AC line in close proximity10.1109/tpwrd.2007.905334 ↗
20. Analysis and treatment of current unbalance abnormal situation of 750 kV double-circuit parallel transmission line10.1051/ijmqe/2023001 ↗
21. Analysis of coupling effects on overhead VSC-HVDC transmission lines from AC lines with shared right of way10.1109/tpwrd.2010.2043373 ↗
22. Analysis of homogeneous phase cross-country faults of double-circuit lines on the same tower
23. Multi factor analysis on induced voltage and current of 500 kV AC/DC transmission lines on the same tower10.13296/j.1001-1609.hva.2022.05.007 ↗
24. Integrated transverse differential protection scheme for double-circuit lines on the same tower10.1109/tpwrd.2017.2765762 ↗
25. A comparative analysis of gradient boosting algorithms10.1007/s10462-020-09896-5 ↗
26. Network intrusion detection based on PSO-Xgboost model10.1109/access.2020.2982418 ↗
27. Crested porcupine optimizer: A new nature-inspired metaheuristic10.1016/j.knosys.2023.111257 ↗
28. Asymmetric GARCH type models for asymmetric volatility characteristics analysis and wind power forecasting10.1186/s41601-019-0146-0 ↗