Research into prediction and influential factors of circuit breaker closing time using BFGS-NN
Source abstract
Abstract
This study enhances the accuracy of controlled closing for 800 kV filter field circuit breakers by analyzing the factors affecting the closing time. A multi-factor prediction model was developed using the Broyden–Fletcher–Goldfarb–Shanno (BFGS) neural network algorithm, incorporating ambient temperature, dwell time, the number of actions, and working hours. On-site operational data were analyzed to build a circuit breaker action time database. The BFGS algorithm trained on these data generated a closing time prediction model, achieving rapid convergence and optimal fit during learning. Results show an average prediction error within ±0.21 ms, with the maximum error tolerance meeting controlled closing requirements. The prediction error decreased as more variables were integrated, confirming that ambient temperature (inverse correlation), dwell time (positive correlation), working hours, and action frequency significantly influence closing times. For instance, lowering the ambient temperature by 40 °C reduced the closing time by ∼1 ms, while increasing the dwell time to 168 h raised it by 2.5 ms. The model enables real-time prediction of closing times using dynamic operational parameters, improving phase-selection precision by 18% compared with conventional methods. This data-driven approach provides theoretical and technical support for optimizing controlled closing in ultra-high voltage systems.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Smart Grid and Power Systems · Power Systems and Technologies · Power System Reliability and Maintenance
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Electric Power Research Institute of Ningxia Electric Power Co., Ltd. 1 , Yinchuan, Ningxia 750002,
School of Electrical Engineering, Dalian University of Technology 2 , Dalian 116024,
School of Computer Science and Technology, Dalian University of Technology 3 , Dalian 116024,
Extra High Voltage Company, State Grid Ningxia Electric Power Co., Ltd. 4 , Yinchuan, Ningxia 750002,
Funding
Electric Power Research Institute of Ningxia Electric Power Co., Ltd.
References (24)
Show source-provided references
1. Research on development of west-to-east power transmission under the environment of new power system construction10.3969/j.issn.1007-290X.2023.09.004 ↗
2. Research of method for selecting phase and controlled switching of high-voltage circuit breaker10.3969/j.issn.1007-290X.2020.006.014 ↗
3. Research and design on mechanical stability of phase selective closing circuit breaker10.13296/j.1001-1609.hva.2022.11.021 ↗
4. Study on closing pre-breakdown characteristics of SF6 circuit breaker during contacts deterioration10.13296/j.1001-1609.hva.2024.04.01 ↗
5. Research status and prospect of high voltage vacuum circuit breaker10.13336/j.1003-6520.hve.20232381 ↗
6. Analysis of unstable factors for phase selection and closing of high voltage AC circuit breaker10.19768/j.cnki.dgjs.2021.24.050 ↗
7. Overview and prospects of controlled closing technology in circuit breakers: A comprehensive review and future outlook10.3969/j.issn.1672-3643.2024.03.005 ↗
8. Analysis of the influence of operating voltage on the opening and closing time of mechanical characteristics of circuit breakers10.13612/j.cnki.cntp.2023.19.043 ↗
9. Synchronous closing time precalculation based on distributed neural network
10. Study of the influence of the closing velocity and the pre-strike on synchronous closing in a vacuum circuit breaker10.19595/j.cnki.1000-6753.tces.2004.07.017 ↗
11. Research on the application of circuit breaker selection and switching system in converter stations10.16086/j.cnki.issn1000-0380.2023080082 ↗
12. Measures and applications for improving the stability of AC filter circuit breaker closing time based on closing recording
13. Test method for opening/closing time of double break circuit breaker when both ends are grounded10.3969/j.issn.1007-290X.2021.012.008 ↗
14. Research on online measurement method for opening and closing time of vacuum circuit breaker10.19768/j.cnki.dgjs.2021.07.027 ↗
15. Research on testing method for opening and closing time of two end grounding circuit breaker10.13296/j.1001-1609.hva.2019.10.010 ↗
16. Measurement method and influencing factors of the dynamic contact resistance of SF6 circuit breakers10.13336/j.1003-6520.hve.20170428019 ↗
17. An adaptive reclosing strategy for mechanical DC circuit breaker10.13336/j.1003-6520.hve.20201478 ↗
18. Influence of different factors on the interruption characteristics of paralleled of high-voltage SF6 circuit breakers with a highly coupled split reactor
19. Online monitoring method of electrical life of high voltage SF6 circuit breaker based on analysis of arcing contact vibration characteristics10.19595/j.cnki.1000-6753.tces.230877 ↗
20. Fracture failure process of key part of air circuit breaker considering spatial shape and position deviation10.19595/j.cnki.1000-6753.tces.l90305 ↗
21. SF6 circuit breaker contact state assessment based on QPSO-SVR algorithm10.13336/j.1003-6520.hve.20220336 ↗
22. 2019
23. Data-driven method for impedance calculation and temperature rise warning of joint of distribution transformer10.13296/j.1001-1609.hva.2024.11.001 ↗
24. Fault fast pinpointing method of high-voltage complex cable lines based on BFGS TDOA10.13648/j.cnki.issn1674-0629.2020.07.004 ↗