Aging condition assessment of cable sheath protectors based on high-order harmonic ratio of leakage current
Source abstract
Abstract
Zinc oxide cable sheath protectors are critical devices in power systems that ensure the safety of cable power supply, and their operating status directly influences the safety of the line. However, prolonged exposure to various over voltages can lead to significant aging, resulting in performance degradation. In this context, leakage-current-based condition monitoring plays an important role in predicting the aging state of cable sheath protectors. This study employs lightning impulse aging methods to investigate the high-frequency characteristics of cable sheath protectors after impact aging, proposing a diagnostic detection indicator for aging status based on the harmonic ratio of the leakage current. Notably, this indicator showed a gradually increasing trend with the aging progression. Therefore, it can be effectively used to assess the aging status of the cable sheath protector, providing technical support for the detection of the aging status of the cable sheath protector.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrical Fault Detection and Protection · High voltage insulation and dielectric phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Inner Mongolia Power (Group) Co.,Ltd.,Inner Mongolia Power Research Institute Branch 1 , Hohhot,
Inner Mongolia Enterprise Key Laboratory of High Voltage and Insulation Technology 2 , Hohhot,
References (26)
Show source-provided references
1. Review of harmonic source modeling methods with the background of renewable energy access10.19783/j.cnki.pspc.211063 ↗
2. Characteristics and influence of switching overvoltage in extra high voltage cables based on EMTP
3. Lightning Over-voltage analysis of EHV transmission lines based on multiple lightning strikes10.13296/j.1001-1609.hva.2022.08.030 ↗
4. On-line monitoring device for lightning induced over-voltage of 10 kV distribution line and its application10.13296/j.1001-1609.hva.2023.04.011 ↗
5. Mechanism and main influencing factors of transient Over-voltage in new energy access system10.14044/j.1674-1757.pcrpc.2022.03.019 ↗
6. A suppression method for overvoltage of a sending end grid caused by commutation failure based on virtual resistance10.19783/j.cnki.pspc.202120 ↗
7. Explosion accident analysis and prevention of resonance overvoltage of 35 kV potential transformer10.13296/j.1001-1609.hva.2023.01.026 ↗
8. Lightning over-voltage and protection of distribution lines caused by lightning striking soil dissipation near buildings10.16188/j.isa.1003-8337.2023.01.012 ↗
9. Experimental study of high current impulse withstand characteristics of entire 10 kV distribution line arrester10.16188/j.isa.1003-8337.2018.02.003 ↗
10. Experiment research on lightning current residual voltage characteristics of 10 kV whole arrester10.16188/j.isa.1003-8337.2018.03.004 ↗
11. An on-line detection method of relative resistive current of MOA10.16188/j.isa.1003-8337.2019.05.024 ↗
12. Online condition monitoring of surge arresters based on third-harmonic analysis of leakage current10.1109/tdei.2017.006334 ↗
13. A novel technique for condition monitoring of metal oxide surge arrester based on fifth harmonic resistive current10.1016/j.epsr.2021.107576 ↗
14. Ageing classification of metal oxide surge arrester using its power factor
15. On-site detection method for resistive current of metal oxide surge arrester based on ground current of capacitive equipment10.16188/j.isa.1003-8337.2022.01.018 ↗
16. Detection technology for 750 kV metal oxide arrester with shunt capacitance10.16188/j.isa.1003-8337.2021.06.002 ↗
17. Review of high-order harmonic resonances of electric railways in China
18. Experimental study of influence of environmental conditions on online monitoring data of metal oxide surge arrester10.13336/j.1003-6520.hve.2008.06.028 ↗
19. Influencing factors of high current impulse withstand capability of 10 kV distribution arrester10.16188/j.isa.1003-8337.2022.05.010 ↗
20. Harmonic characteristics analysis and modeling of EMU arrester10.13336/j.1003-6520.hve.20220367 ↗
21. 2021
22. 2020
23. Research of degradation performance of 35 kV MOA under lightning impulses10.16188/j.isa.1003-8337.2014.04.014 ↗
24. Research on degradation performance of 110 kV full-scale ZnO MOA under lightning impulses10.13648/j.cnki.issn1674-0629.2015.07.007 ↗
25. Leakage current characteristics and ageing assessment technology of roof arrester under ultra harmonics overvoltage10.1049/hve2.12141 ↗
26. Study on failure mechanism of arrester on roof of high speed electric multiple units under high-order harmonics10.16265/j.cnki.issn1003-3033.2019.S1.017 ↗