journal article·2024-12-01Open access

Measurement of relative neutron energy response curve of plastic scintillator detector based on the back-n-white neutron source at CSNS

Yapeng Zhang, Jinlu Ruan, Liang Chen, Jianfu Zhang, Shiyi He, Kuo Zhao, Leidang Zhou, Silong Zhang, Naizhe Zhao, Yang Li, Wenyu Shu, Fangbao Wang, Xiaoping Ouyang

AIP Advances· Volume 14· Issue 12

Abstract

The plastic scintillator detector is widely used to measure pulsed radiation fields, and a high-quality neutron energy response curve is crucial for accurately determining neutron yields. Traditionally, the neutron energy response curve can be obtained by the simulation of the performance of neutron detectors via the knowledge of the light yield of secondary particles or direct measuring energy response. Both methods record signals by a data acquisition system in the counting mode. This work establishes a new model to directly measure the energy response to neutrons of a plastic scintillator detector in current mode with white source spectra. The plastic scintillator detector can be triggered externally. There is no signal loss and dead time, and it is possible to calibrate the neutron detector with a high-intensity neutron source. Efficiencies can be determined at all energies simultaneously, and a rapid calibration of the plastic scintillator detector is available. To validate the experimental results, the theoretical values are obtained by Geant4 simulation, and the results reproduce the shapes of the experimental curves reasonably well. The neutron energy response curves of the detector show that when the thickness of the scintillator is reduced from 3 to 1 mm, the reduction ratio of gamma signal intensity is greater than that of neutron signal intensity, which leads to an increase in the neutron–gamma sensitivity ratio. Meanwhile, the thin scintillator thickness can obtain a somewhat flatter neutron energy response curve compared with other thicknesses.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Detection and Scintillator Technologies · Nuclear Physics and Applications · Radiation Therapy and Dosimetry

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology 1 , Xi’an 710024,

Xi’an Research Institute of Hi-Tech 2 , Xi’an 710025,

School of Microelectronics, Xi’an Jiaotong University 3 , Xi’an 710049,

Xiangtan University 4 , Xiangtan, Hunan Province 411105,

Funding

Jinlu Ruan · Kuo Zhao

References (31)

Show source-provided references
1. Intrinsic evaluation of n/γ discrimination in plastic scintillators10.1109/tns.2014.2327292 ↗
2. Pulse-shape discrimination of the new plastic scintillators in neutron–gamma mixed field using fast digitizer card10.1016/j.radphyschem.2015.05.007 ↗
3. Thin plastic scintillating foil for measuring pulsed neutron flux in high gamma-ray environment10.1088/1009-0630/7/5/006 ↗
4. Fast neutron response characterization of an EJ-276 plastic scintillator for use as a neutron monitor10.1016/j.nima.2023.168216 ↗
5. Fast neutron physics: Part 1, techniques10.1063/1.3057071 ↗
6. Theoretical research of a new measurement method of pulse fission neutrons
7. A Measurement of the27Al (d, n) spectrum for use in neutron detector calibration10.13182/nse98-a1971 ↗
8. Analysis of response data for several organic scintillators10.1016/0029-554x(70)90768-8 ↗
9. Measurement of the response of several organic scintillators to electrons, protons and deuterons10.1016/0029-554x(68)90189-4 ↗
10. Flügge · 1958 · 193
11. Monte Carlo modeling of neutron sensitivity for foil- or fiber- plastic scintillator10.3969/j.issn.0258-0934.2004.04.005 ↗
12. Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass10.1088/1748-0221/15/11/p11020 ↗
13. Measurements of the light output functions of plastic scintillator using 9Be(d,n)10B reaction neutron source10.1088/1674-1137/34/7/011 ↗
14. Measurement and application of Be(d, n) reaction neutron source10.3788/hplpb20112301.0209 ↗
15. Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors10.1016/j.nima.2013.03.032 ↗
16. Performance of the versatile array of neutron detectors at low energy (VANDLE)10.1016/j.nima.2016.08.054 ↗
17. Neutron sensitivity calibration of fission target detection system based on SiC detector
18. The experimental investigation of the neutron energy response of the thin ST-401 scintillator10.7498/aps.55.2165 ↗
19. Back-n white neutron facility for nuclear data measurement at CSNS10.1088/1748-0221/12/07/P07022 ↗
20. Design of back-streaming white neutron beam line at CSNS10.1016/j.apradiso.2017.11.013 ↗
21. Back-n white neutron source at CSNS and its applications10.1007/s41365-021-00846-6 ↗
22. The C6D6 detector system on the Back-n beam line of CSNS10.1007/s41605-019-0129-8 ↗
23. Enhanced performance of a pulsed neutron detector by the plastic scintillator with a photonic crystal10.1063/1.5048230 ↗
24. Double-bunch unfolding methods for the Back-n white neutron source at CSNS10.1088/1748-0221/15/03/p03026 ↗
25. GEANT4—A simulation toolkit10.1016/s0168-9002(03)01368-8 ↗
26. Calibration of an organic scintillator for neutron spectrometry10.1016/0029-554x(68)90003-7 ↗
27. New physics model in GEANT4 for the simulation of neutron interactions with organic scintillation detectors10.1016/j.nima.2017.06.021 ↗
28. Measurement of EJ-228 plastic scintillator proton light output using a coincident neutron scatter technique10.1016/j.nima.2019.163192 ↗
29. Nonproportionality of scintillator detectors: Theory and experiment. II10.1109/tns.2011.2167687 ↗
30. A multi-cell fission chamber for fission cross-section measurements at the Back-n white neutron beam of CSNS10.1016/j.nima.2019.06.014 ↗
31. Neutron energy spectrum measurement of the Back-n white neutron source at CSNS10.1140/epja/i2019-12808-1 ↗