Breakdown calculation of zoning tests by positive lightnings
Source abstract
Abstract
To simulate a natural lightning strike, the breakdown should occur within 1–3 μs in an aircraft lightning zoning test. However, the breakdown voltage–time characteristic of the combined gap is hard to derive because of the complex breakdown process. In this paper, a series of positive lightning impulse discharge tests in a rod electrode–floating aircraft model–plate combined gap were conducted. The leader propagation processes in both sub-gaps were observed using a high-speed camera. The potential of the floating aircraft model was analyzed. We propose a potential calculation model for the floating aircraft during the leader propagation phase. After fitting test data, an empirical formula for the connected streamer plasma was given. Taking that model into account, the calculation result of the average breakdown time of the combined gap has an error of <5.7%.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Lightning and Electromagnetic Phenomena · High voltage insulation and dielectric phenomena · Electrostatic Discharge in Electronics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electrical Engineering and Automation, Hefei University of Technology 1 , Tunxi Road, 230000 Hefei, China
Anhui Provincial Laboratory of Aircraft Lightning Protection 2 , Daoxiang Road, 236000 Hefei, China
Aviation Key Laboratory of Science and Technology on High Intensity Electromagnetic Environment Protection 3 , Daoxiang Road, 236000 Hefei, China
Funding
Ministry of Industry and Information Technology of the People’s Republic of China
References (24)
Show source-provided references
1. J. Geophys. Res. · 1993 · 9812 · 91310.1029/93JD00626 ↗
2. J. Aircr. · 1984 · 21 · 60710.2514/3.45030 ↗
3. J. Atmos. Electr. · 1992 · 12 · 8310.1541/jae.12.83 ↗
4. IEE Proc.—Sci., Meas. Technol. · 1998 · 145 · 18510.1049/ip-smt:19982206 ↗
5. IEE Proc.—Sci., Meas. Technol. · 1998 · 145 · 19310.1049/ip-smt:19982011 ↗
6. J. Geophys. Res.: Atmos. · 2020 · 125 · e2019JD03124510.1029/2019JD031245 ↗
7. IEEE Trans. Power Delivery · 1994 · 9 · 197210.1109/61.329529 ↗
8. IEEE Trans. Power Appar. Syst. · 1977 · 96 · 22710.1109/T-PAS.1977.32328 ↗
9. IEEE Trans. Power Delivery · 1995 · 10 · 136010.1109/61.400917 ↗
10. IEEE Trans. Power Delivery · 2014 · 29 · 239410.1109/TPWRD.2014.2306688 ↗
11. IEEE Trans. Dielectr. Electr. Insul. · 2015 · 22 · 118610.1109/TDEI.2015.7076821 ↗
12. IEEE Trans. Power Appar. Syst. · 1985 · 6 · 155610.1109/TPAS.1985.319172 ↗
13. 2016 · 1
14. Atmos. Res. · 2014 · 149 · 31610.1016/j.atmosres.2014.05.004 ↗
15. C. R. Phys. · 2002 · 3 · 133510.1016/S1631-0705(02)01414-7 ↗
16. Electr. Power Syst. Res. · 2019 · 173 · 12210.1016/j.epsr.2019.03.018 ↗
17. IEEE Trans. Power Delivery · 2018 · 33 · 321110.1109/TPWRD.2018.2874701 ↗
18. IEEE Trans. Power Delivery · 1996 · 11 · 35310.1109/61.484035 ↗
19. IEEE Trans. Dielectr. Electr. Insul. · 2018 · 25 · 112110.1109/TDEI.2018.007023 ↗
20. IEEE Trans. Dielectr. Electr. Insul. · 2013 · 20 · 111210.1109/TDEI.2013.6571424 ↗
21. IEEE Trans. Dielectr. Electr. Insul. · 2010 · 17 · 210.1109/TDEI.2010.5411995 ↗
22. 1991 · 138
23. Rev. Sci. Instrum. · 2014 · 85 · 04611210.1063/1.4871697 ↗
24. AIP Adv. · 2024 · 14 · 03514810.1063/5.0199336 ↗