Research on current control strategy of overvoltage flexible suppression device based on cascaded linear-nonlinear active disturbance rejection controller
Source abstract
Abstract
In order to improve the immunity and speed tracking performance of active inverters in resonant overvoltage flexible suppression under load variation, parameter perturbation, and other uncertainties, a current control strategy of a resonant overvoltage flexible grounding device based on a cascading linear-nonlinear active disturbance rejection controller is proposed in this paper. First, the mathematical model of the flexible device considering load disturbance and parameter mismatch is established. Second, a cascade of linear and nonlinear extended state observers is designed to estimate and compensate the uncertain disturbance of the system in real time. The former linear extended state observer ensures the stability of the system under large disturbance, and the latter nonlinear extended state observer further improves the estimation accuracy of the disturbance by using the nonlinear mechanism. Finally, the flexible grounding system based on PI control and cascaded linear-nonlinear active disturbance rejection control (CL-NLADRC) is simulated and compared. Compared with PI control, NLADRC, and CLADRC, the current drop of the proposed CL-NLADRC during loading is 0.03 kA, which is 81.1%, 85.7%, and 73% of the three, respectively, and the regulation time is 13 ms, which is 82%, 75%, and 18.7% shorter than the three, respectively. The speed increase during load shedding is 93.5%, 80.5%, and 74.3% of the three, and the adjustment time is shortened by 80%, 73%, and 28%, respectively. The superiority of the proposed method is verified.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Vibration and Dynamic Analysis · Microgrid Control and Optimization · Multilevel Inverters and Converters
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Intelligent Manufacturing, Qingdao Huanghai University , Qingdao 266427, China
Funding
Shandong Provincial Natural Science Foundation
References (24)
Show source-provided references
1. Impacts of wind farms with different control strategies on power grids voltage stability
2. Suppressing method of three-phase unbalanced overvoltage based on distribution networks flexible grounding control10.13334/j.0258-8013.pcsee.2014.04.021 ↗
3. Active arc-suppression method of grounding fault for distribution network based on secondary injection
4. Research on active suppression method of three-phase unbalanced overvoltage for distribution networks10.19595/j.cnki.1000-6753.tces.2015.09.008 ↗
5. Adaptive model predictive current control for PMLSM drive system10.1109/tie.2022.3179550 ↗
6. Sliding mode speed control for tubular permanent magnet linear motors based on the internal model10.13334/j.0258-8013.pcsee.180223 ↗
7. Adaptive backstepping sliding mode control for PMLSM based on multi-segment velocity planning10.19595/j.cnki.1000-6753.tces.170024 ↗
8. Recursive terminal sliding mode control of permanent magnet synchronous linear motor based on finite-time state observer10.13334/j.0258-8013.pcsee.222508 ↗
9. An iterative learning control based on improved multiple input and multiple output model free adaptive control for two-dimensional linear motor10.19595/j.cnki.1000-6753.tces.200719 ↗
10. Nonlinear robust optimal control via adaptive dynamic programming of permanent-magnet linear synchronous motor drive for uncertain two-axis motion control system10.1109/tia.2019.2961637 ↗
11. From PID to active disturbance rejection control10.1109/tie.2008.2011621 ↗
12. 2008
13. Nonlinear active disturbance rejection controller design and tuning for permanent magnet synchronous motor speed control system10.13334/j.0258-8013.pcsee.200018 ↗
14. Servo systems with double closed-loops based on active disturbance rejection controllers10.13334/j.0258-8013.pcsee.161957 ↗
15. Scaling and bandwidth parameterization based controller tuning
16. New LADRC design for permanent magnet linear synchronous motor considering dynamic response of current loop10.13334/j.0258-8013.pcsee.180901 ↗
17. Adaptive LADRC-based disturbance rejection method for electromechanical servo system10.1109/tia.2019.2955664 ↗
18. Cascade extended state observer for active disturbance rejection control applications under measurement noise10.1016/j.isatra.2020.09.007 ↗
19. Enhanced linear ADRC strategy for HF pulse voltage signal injection-based sensorless IPMSM drives10.1109/tpel.2018.2814056 ↗
20. Nonlinear active disturbance rejection control strategy for permanent magnet synchronous motor drives10.1109/tec.2022.3150796 ↗
21. On the necessity, scheme, and basis of the linear-nonlinear switching in active disturbance rejection control10.1109/TIE.2016.2611573 ↗
22. H. Zhengjie , “Research on key technologies of permanent magnet synchronous motor drive system based on active disturbance rejection control,” Ph.D. thesis, Jilin University, 2022.10.1109/ICCSSE59359.2023.10244939 ↗
23. Aquila optimizer: A novel meta-heuristic optimization algorithm10.1016/j.cie.2021.107250 ↗
24. African vultures optimization algorithm: A new nature-inspired metaheuristic algorithm for global optimization problems10.1016/j.cie.2021.107408 ↗