An integrated calibration method for the cross-shaped magnetic gradiometer
Source abstract
Abstract
The measurement accuracy of a magnetic gradiometer relies on magnetometer consistency, measurement accuracy, and assembly technology. The traditional methods calibrate measurement error, misalignment error, and the interference magnetic field independently. However, after a long time of work, the calibration parameters will inevitably change. Furthermore, it will waste a lot of manpower and material resources if the magnetic gradiometer is disassembled and calibrated step by step. Given the above problems, a novel attitude-independent calibration algorithm using a limited number of measurement points is proposed, which can effectively overcome the measurement distortion of the magnetic gradiometer and does not rely on a reference magnetometer. For the cross-shaped magnetic gradiometer, the simulation results show that the error after integrated calibration is reduced to less than 8% of the error before calibration. The test results suggest that the magnetic gradient results before calibration are even up to 1.5 µT/m, whereas the magnetic gradient results after the integrated calibration are less than 100 nT/m.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Inertial Sensor and Navigation · Geophysics and Gravity Measurements · Magnetic Field Sensors Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Aviation Operations and Services, Aviation University of Air Force , Changchun 130041, Jilin, China
Funding
Laboratory Fund Project of Equipment Department
References (18)
Show source-provided references
1. Review: Progress in SQUID-based geophysical precision measurement technology10.11916/j.issn.1005-9113.20025 ↗
2. Mitigation of platform generated magnetic noise impressed on a magnetic sensor mounted in an autonomous underwater vehicle
3. Initial evaluation of the real-time tracking gradiometer designed for small unmanned underwater vehicles
4. Field-stable SQUID magnetometer with sub-fT Hz−1/2 resolution based on sub-micrometer cross-type Josephson tunnel junctions10.1088/0953-2048/24/6/065009 ↗
5. Thin-film based ultralow noise SQUID magnetometer10.1109/tasc.2016.2530699 ↗
6. New methods for interpretation of magnetic vector and gradient tensor data I: Eigenvector analysis and the normalized source strength10.1071/eg12020 ↗
7. Underwater operation of a full tensor SQUID gradiometer system10.1088/1361-6668/aaf245 ↗
8. Magnetometer calibration using Kalman filter covariance matrix for online estimation of magnetic field orientation10.1109/tim.2014.2302240 ↗
9. Extension of a two-step calibration methodology to include nonorthogonal sensor axes10.1109/taes.2008.4655364 ↗
10. Attitude-independent magnetometer calibration for marine magnetic surveys: Regularization issue10.1088/1742-2132/10/4/045002 ↗
11. Complete triaxis magnetometer calibration in the magnetic domain10.1155/2010/967245 ↗
12. Geometric approach to strapdown magnetometer calibration in sensor frame10.3182/20080408-3-ie-4914.00031 ↗
13. Calibration of a fluxgate magnetometer array and its application in magnetic object localization10.1088/0957-0233/24/7/075102 ↗
14. Error compensation of tetrahedron magnetic gradiometer10.3788/ope.20142210.2683 ↗
15. UXO survey using vector magnetic gradiometer on autonomous underwater vehicle
16. Fast rotation calibration of sensor array in magnetic gradient tensor system10.3788/ope.20182607.1813 ↗
17. A vehicle magnetic noise compensation method for the tetrahedron magnetic gradiometer10.7498/aps.63.110702 ↗
18. Experiment research of magnetic dipole model applicability for a magnetic object10.3969/j.issn.1005-0930.2010.05.016 ↗