journal article·2018-09-01Open access

Movement compensation during carbon dioxide coronary angiography: In-vitro validation

Ivan Corazza, Sonia Sapignoli, Pier Luca Rossi, Alessandro Lombi, Edoardo Pirazzini, Nevio Taglieri, James G. Caridi, Romano Zannoli

AIP Advances· Volume 8· Issue 9

Abstract

The aim of this in vitro study was to evaluate the feasibility of movement compensation for CO2 coronary angiography. The use of CO2 as a contrast medium for coronary angiography in a routine clinical setting is still premature. Nonetheless, the gas can solve most of the problems related to iodine contrast-induced nephropathy and can be safely used for patients with renal insufficiency. In a previous work [I. Corazza et al., AIP Adv. 8(1), 015225 (2018)], we demonstrated that an adequate setting of the CO2 injection parameters (pressures and volumes) allows gas injection into the coronaries, avoiding reflux into the aorta and cerebral circulation. A mechanical mock simulating coronary circulation and movement was used to simulate different CO2 injection conditions. Simultaneous acquisition of ECG and optical images allowed synchronous frame extraction for post-processing analysis, like masking and stacking processes. A single test with a radiological apparatus was done to demonstrate the feasibility of the technique. By injecting CO2 at a pressure between the dicrotic notch and diastolic value, no reflux into the aorta was observed and the new software yielded final optical images of clinical quality after about 8 seconds of injection. The feasibility test under the X-ray apparatus gave promising results. CO2 coronary angiography is still far from becoming a clinical standard, but our bench evaluation demonstrates that if the injection parameters are well-controlled and physiological values known, CO2 can be used as a contrast agent not only for the lower part of the body, but also for the coronary arteries, respecting basic safety standards.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cardiovascular and Diving-Related Complications · Renal and Vascular Pathologies · Traumatic Brain Injury and Neurovascular Disturbances

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Experimental, Diagnostic and Specialty Medicine Department, University of Bologna 1 , Via Massarenti 9, 40138 Bologna, Italy

Department of Physics and Astronomy, University of Bologna 2 , Viale Berti Pichat 6/2, 40127 Bologna, Italy

INFN Bologna 3 , Viale Berti Pichat 6/2, 40127 Bologna, Italy

Health Sciences Center, Tulane University 4 , 1430 Tulane Avenue, New Orleans, Louisiana 70112-2699, USA

References (15)

Show source-provided references
1. J. Vasc. Interv. Radiol. JVIR · 1997 · 8 · 38310.1016/s1051-0443(97)70577-3 ↗
2. AJNR Am. J. Neuroradiol. · 1998 · 19 · 261
3. Clin. Cardiol. · 1996 · 19 · 46110.1002/clc.4960190604 ↗
4. J. Vasc. Surg. · 2008 · 48 · 52710.1016/j.jvs.2008.04.061 ↗
5. Catheter. Cardiovasc. Interv. · 2015 · 85 · 87010.1002/ccd.25722 ↗
6. Radiol. Clin. North Am. · 2009 · 47 · 81310.1016/j.rcl.2009.07.002 ↗
7. Ital. Heart J. Off. J. Ital. Fed. Cardiol. · 2003 · 4 · 668
8. AIP Adv. · 2018 · 8 · 01522510.1063/1.5016601 ↗
9. Phys. Medica-Eur. J. Med. Phys. · 2013 · 29 · 3310.1016/j.ejmp.2011.11.003 ↗
10. J. Invasive Cardiol. · 2013 · 25 · 28
11. Phys. Med. · 2009 · 25 · 9410.1016/j.ejmp.2008.02.007 ↗
12. J. Mech. Med. Biol. · 2005 · 5 · 36910.1142/s0219519405001503 ↗
13. J. Biomech. · 2014 · 47 · 161810.1016/j.jbiomech.2014.03.001 ↗
14. Comput. Methods Programs Biomed. · 2014 · 117 · 26710.1016/j.cmpb.2014.08.002 ↗
15. 2007