journal article·2018-05-01Open access

On the radiated EMI current extraction of dc transmission line based on corona current statistical measurements

Yong Yi, Zhengying Chen, Liming Wang

AIP Advances· Volume 8· Issue 5

Abstract

Corona-originated discharge of DC transmission lines is the main reason for the radiated electromagnetic interference (EMI) field in the vicinity of transmission lines. A joint time-frequency analysis technique was proposed to extract the radiated EMI current (excitation current) of DC corona based on corona current statistical measurements. A reduced-scale experimental platform was setup to measure the statistical distributions of current waveform parameters of aluminum conductor steel reinforced. Based on the measured results, the peak value, root-mean-square value and average value with 9 kHz and 200 Hz band-with of 0.5 MHz radiated EMI current were calculated by the technique proposed and validated with conventional excitation function method. Radio interference (RI) was calculated based on the radiated EMI current and a wire-to-plate platform was built for the validity of the RI computation results. The reason for the certain deviation between the computations and measurements was detailed analyzed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Aerosol Filtration and Electrostatic Precipitation · High voltage insulation and dielectric phenomena · Lightning and Electromagnetic Phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Tsinghua University 1 , Shenzhen, Guangdong 518055, People’s Republic of China

Graduate School at Shenzhen, Tsinghua University 2 , Shenzhen, Guangdong 518055, People’s Republic of China

Funding

National Natural Science Foundation of China · China Postdoctoral Science Foundation

References (16)

Show source-provided references
1. 2000
2. 1965
3. J. Phys. D: Appl. Phys. · 1975 · 8 · 41610.1088/0022-3727/8/4/014 ↗
4. Phys. Plasmas · 2011 · 18 · 123503-110.1063/1.3671970 ↗
5. Phys. Plasmas · 2014 · 21 · 0321110.1063/1.4868966 ↗
6. 1976
7. IEEE Trans. Power App. Syst. · 1977 · 96 · 187210.1109/t-pas.1977.32521 ↗
8. 1976
9. IEEE Trans. Power Del. · 1990 · 5 · 143610.1109/61.57986 ↗
10. IEEE Trans. Power Del. · 1991 · 6 · 179910.1109/61.97724 ↗
11. IEEE Trans. Power Del. · 2010 · 25 · 295010.1109/tpwrd.2010.2051689 ↗
12. IEEE Trans. Power App. Syst. · 1969 · PAS-88 · 106110.1109/TPAS.1969.292506 ↗
13. IEEE Trans. Power App. Syst. · 1974 · PAS-93 · 23310.1109/tpas.1974.293937 ↗
14. 1993
15. IEEE Trans. Power App. Syst. · 1972 · PAS-91 · 30510.1109/TPAS.1972.293364 ↗
16. IEEE Trans. Power App. Syst. · 1969 · PAS-88 · 151210.1109/tpas.1969.292279 ↗