Evaluation of magnetic field’s uniformity inside electromagnetic coils using graphene
Source abstract
Abstract
The distribution of the magnetic field in electromagnetic coils, such as those employed in magnetic resonance imaging (MRI), is evaluated in this paper, through graphene gyrotropic properties. Initially, the rotation of an incident linearly polarized plane wave, due to an infinite graphene layer, is studied theoretically via the extraction of the perpendicular, to the polarization, electric component of the transmitted wave. Moreover, the influence of the magnetic bias field strength on this component is, also, examined, indicating the eligibility of graphene to detect magnetostatic field variations. To this aim, a specific device is proposed, consisting of a high frequency source, an electric field detector, and a finite graphene sheet that differs from the infinite one of the analytical case. To quantify the distance that the gyrotropic effects are detectable, the effective region is introduced and extracted via a properly modified finite-difference time-domain (FDTD) algorithm. The featured device is verified through a setup comprising a uniform electromagnetic coil, where the generated magnetostatic field is calculated at several cross-sections of the coil and compared to actual field values. Results indicate the accuracy and sensitivity of the designed device for the unambiguous regions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Graphene research and applications · Plasmonic and Surface Plasmon Research · Quantum and electron transport phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Aristotle University of Thessaloniki 1 , Thessaloniki GR-54124, Greece
21-17-134 Omachi, Asahikawa 070-0841, Japan
Niigata Institute of Technology 3 , Kashiwazaki 945-1195, Japan
Funding
National Scholarships Foundation of Greece
References (18)
Show source-provided references
1. Science · 2004 · 306 · 66610.1126/science.1102896 ↗
2. Nature Photon. · 2012 · 6 · 74910.1038/nphoton.2012.262 ↗
3. Nature Photon. · 2016 · 10 · 4610.1038/nphoton.2015.223 ↗
4. Appl. Phys. Lett. · 2013 · 102 · 13110110.1063/1.4799173 ↗
5. Appl. Phys. Lett. · 2012 · 100 · 13111110.1063/1.3698133 ↗
6. Appl. Phys. Lett. · 2012 · 100 · 21311010.1063/1.4721453 ↗
7. Appl. Phys. Lett. · 2017 · 111 · 08111010.1063/1.4990620 ↗
8. J. Appl. Phys. · 2012 · 112 · 12490610.1063/1.4769749 ↗
9. Phys. Rev. B · 2016 · 94 · 03540110.1103/physrevb.94.035401 ↗
10. Phys. Rev. B · 2016 · 94 · 07541310.1103/physrevb.94.075413 ↗
11. Appl. Phys. Lett. · 2012 · 101 · 23160510.1063/1.4769095 ↗
12. Appl. Phys. Lett. · 2013 · 102 · 19190110.1063/1.4804437 ↗
13. Med. Image Analysis · 2006 · 10 · 23410.1016/j.media.2005.09.004 ↗
14. 2005
15. IEEE Trans. Magn. · 2017
16. J. Phys.: Condens. Matter · 2006 · 19 · 02622210.1088/0953-8984/19/2/026222 ↗
17. Appl. Phys. Lett. · 2011 · 98 · 02191110.1063/1.3543633 ↗
18. J. Mat. Sci. · 1983 · 18 · 189910.1007/bf00554981 ↗