Development of a planar-type high sensitivity metallic contaminant detector
Source abstract
Abstract
Metallic contaminant detectors based on the balanced coil system are widely used in the food industry. In the balanced coil system, an excitation coil and two identical pickup coils are used in a way that the magnetic coupling of pickup coils to the excitation coil is cancelled with each other when no metallic contaminants present. In a conventional system, the excitation coil and the pickup coil are planar and are parallel, therefore the magnetic coupling is strong even if there is no metallic contaminant. Such strong magnetic coupling makes balancing procedure tedious. In this paper, we introduce a new coil system in which pickup coils are set orthogonal to the excitation coil, making the magnetic coupling much small compared to conventional counterpart. Pickup coils are equipped with thin magnetic cores and placed inside the excitation coil being parallel to the excitation coil plane. The balancing method consists of two steps; the one is geometrical and the other is digital processing including down conversion. Experiments are carried out to show the detection capability of ferromagnetic contaminants and non-magnetic contaminants.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Biosensors and Analytical Detection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Kyushu University , Kasuga-shi Fukuoka 816-0811, Japan
References (6)
Show source-provided references
1. Approaches to foreign body detection in foods10.1016/s0924-2244(97)00003-4 ↗
2. Development of high-sensitivity duw and M series metal detectors
3. Metal Detection, in the web page of Safe food 360, http://safefood360.com/resources/Metal-Detection.pdf as of Nov. 10, 2016.
4. Development of metallic contaminant detection system using RF high-Tc SQUIDs for food inspection10.1109/tasc.2014.2361893 ↗
5. Detection of alien metallic particles by using a high frequency magnetic field
6. 1999